NFPA 10 Exam 71 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 9 pages • 2023
-
Available in package deal
-
- $11.39
- 4x sold
- + learn more
NFPA 10 Exam 71 Questions with Verified Answers 
 
When should wheeled fire extinguishers be considered? - CORRECT ANSWER • High hazard areas are present. 
• Limited available personnel are present. 
Requiring: High agent flow rate, Increased agent stream range, increased agent capacity 
 
NON-DOT low pressure fire extinguisher cylinders that pass a hydrostatic test shall have the following recorded on a label: - CORRECT ANSWER • Month and year test was performed (perforated) 
• Test pre...
-
F80 Exam Questions and Answers Graded A
- Exam (elaborations) • 14 pages • 2023 Popular
- Available in package deal
-
- $9.99
- 3x sold
- + learn more
F80 Exam Questions and Answers Graded A After what date was the F-24 certificate of Fitness not recognized. July 31, 2014 
How often must this certificate be renewed? Every 3 years 
In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless shelter required? Homeless shelters, one-way voice communication systems, or occupied for more tha n fifteen persons for a period of more than 30 days. 
What is the certificate of occupancy? Determines the number ...
-
F80 Exam Questions and Answers Latest 2024 | Graded A+
- Exam (elaborations) • 23 pages • 2024
- Available in package deal
-
- $12.48
- 1x sold
- + learn more
F80 Exam Questions and Answers Latest 2024 | 
Graded A+ 
After what date was the F-24 certificate of Fitness not recognized. - July 31, 2014 
How often must this certificate be renewed? - Every 3 years 
In what types of buildings and occupancies are coordinators of fire safety and alarm systems in 
homeless shelter required? - Homeless shelters, one-way voice communication systems, or 
occupied for more tha n fifteen persons for a period of more than 30 days. 
What is the certificate of occupanc...
-
IICRC - AMRT Exam, Top Questions and answers, 100% Accurate, graded A+
- Exam (elaborations) • 19 pages • 2023
-
Available in package deal
-
- $12.49
- 11x sold
- + learn more
IICRC - AMRT Exam, Top Questions and answers, 100% Accurate, graded A+ 
 
 
S500 (Water) // S520 (Mold) // NY City Guidelines - -In general, which remediation guidelines/standards should a remediator be familiar with? 
 
S520 Standard for Professional Mold Remediation - -The industry standard of care document for mold remediation contractors is...? 
 
Condition 1 // Normal or uncontaminated building or items // Indoor environment that may have settled spores, fungal fragments whose identity; loc...
-
FDNY F-80 Fire Safety & Alarm Systems in Homeless Shelters Test (2023 Q&A)
- Other • 9 pages • 2023
-
- $10.49
- 2x sold
- + learn more
F-80 Coordinator of Fire Safety and Alarm Systems in Homeless Shelters Test. 
 
GOOD As the F-80 C of F holder, you notice a minor defect in the fire protection system and report it to the building owner. In the event the issue is still not corrected three months later, what would be the next step that you are required to take? 
 
GOOD Typical causes of fires in homeless shelters are considered which of the following? 
 
GOOD Shelter staff members shall be readily identifiable at all times whi...
Too much month left at the end of the money?
-
CM 1070|143 Final Questions With Correct Answers| download to pass|2024
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $7.99
- 1x sold
- + learn more
to enhance occupant comfort and health leads to _______ - ️️Social Benefits 
 
1/2 of global greenhouse emissions can be attributed to buildings - ️️T 
 
The benefits of sustainable design and construction offer the potential to change the way in which we as humans face the challenges of the next decade - ️️T 
 
Which of the following is NOT an economic benefit for sustainable construction: 
a. Reducing operating cost 
b. Improving the image of the building 
c. Creating new business...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023.
- Exam (elaborations) • 20 pages • 2023
-
- $13.09
- 8x sold
- + learn more
Certificate of Fitness for Citywide Sprinkler Systems (S-12) 
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023. 
 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. 
 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. 
 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. 
 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANN...
-
F-07 FIRE & EMERGENCY DRILL CONDUCTOR |24 QUESTIONS AND ANSWERS|GUARANTEED SUCCESS
- Exam (elaborations) • 3 pages • 2023
-
Available in package deal
-
- $13.99
- 2x sold
- + learn more
Building occupants 
All people in the building 
 
 
 
Central Station Company 
A facility that receives alarm signals from a protected premises and retransmits them to the FDNY 
 
 
 
Evacuation 
Emptying of a building of all occupants due to fire or emergency 
 
 
 
Emergency Preparedness Plan 
In even of a fire or emergency there are procedures in place that can be implemented to provide information, guidance, direction and assistance to protect occupants. Including evacuation, relocation, and...
-
S95 Personal Exam Questions & Answers | 75 Questions with 100% Correct Answers | Updated & Verified
- Exam (elaborations) • 8 pages • 2023
-
- $10.49
- 4x sold
- + learn more
Which duties can an S-95 Certificate of Fitness holder perform? - Visual Inspections Only - 
of fire alarm system components and smoke detectors 
What is the primary purpose of Fire Alarm Systems? - To warn building occupants and 
transmit signals indicating a fire condition to the Fire Department via central station. 
What is a Fire Alarm signal? - The signal initiated by a fire alarm initiating device such as a 
manual fire alarm pull station, smoke detector, water-flow switch, or any device i...
-
Texas Mold Remediation Contractor State Exam 2021-2024 Questions & Answers
- Exam (elaborations) • 8 pages • 2024
-
- $13.49
- 1x sold
- + learn more
Texas Mold Remediation Contractor State Exam Questions & Answers 
What does IICRC stand for? - ANS-Institute of Inspection Cleaning and Restoration Certification 
What are the 5 principles of Mold Remediation? - ANS-1. Safety and Health Workers and Occupants 
2. Document the Conditions and Work Processes 
3. Control the Contaminate at is Source 
4. Physically Remove the Contamination(Source Removal) 
5. Correct the Moisture Problem to Prevent Recontamination 
What does SBS stand for? - ANS-Sic...
-
IFSTA Chapter 20, 21 & 22 Exam | Questions and Verified Answers| 100% Correct
- Exam (elaborations) • 35 pages • 2023
-
Available in package deal
-
- $10.99
- 1x sold
- + learn more
IFSTA Chapter 20, 21 & 22 Exam | Questions and Verified Answers| 100% Correct 
 
Q: Which duty would a firefighter perform if he or she were acting as crew leader? 
Select one: 
a. Coordinating resources with other resources at the scene 
b. Investigating the cause of the fire 
c. Acting as the point of communication between the IC and the dispatch center 
d. Determining whether the incident is approached with a defensive or offensive strategy 
 
 
Answer: 