Mechanics Exam Study Guide with Complete Solutions 2023
- Tentamen (uitwerkingen) • 11 pagina's • 2023
- Ook in voordeelbundel
-
- $8.99
- + meer info
Mechanics Exam Study Guide with Complete Solutions 2023 
** An MOV burns out, you replace it but cannot read voltage or resistance. What should you do? - Correct Answer Replace it with a larger one (630) 
 
* On a Ward-Leonard circuit, the brake is set but the motor is trying to slip through the brake. What circuit is the issue? - Correct Answer Suicide circuit (425) 
 
** A Hydro runs up with no load but does not run up with a full load. What is the issue? - Correct Answer The relief valve is s...
-
Mechanics Exam Question and answers 100% correct 2023/2024
- Tentamen (uitwerkingen) • 15 pagina's • 2024
-
Ook in voordeelbundel
-
- $13.49
- + meer info
Mechanics Exam Question and answers 100% correct 2023/2024 
** An MOV burns out, you replace it but cannot read voltage or resistance. What should you do? - correct answer Replace it with a larger one (630) 
 
* On a Ward-Leonard circuit, the brake is set but the motor is trying to slip through the brake. What circuit is the issue? - correct answer Suicide circuit (425) 
 
** A Hydro runs up with no load but does not run up with a full load. What is the issue? - correct answer The relief valve i...
-
Elevator Mechanic Exam Review | 215 Questions with 100% Correct Answers | Verified | Latest Update 2024
- Tentamen (uitwerkingen) • 22 pagina's • 2024
-
- $12.49
- + meer info
A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What 
sheave is required? - Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What 
should you do? - Replace it with a larger MOV 
On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the 
issue? - Suicide Circuit 
You have an old DC motor ...
-
Elevator Mechanic 213 Exam Review Questions with 100% Correct Answers | Updated | Guaranteed A+
- Tentamen (uitwerkingen) • 24 pagina's • 2024
- Ook in voordeelbundel
-
- $8.49
- + meer info
A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What sheave is required? - ️️Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave 
 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - ️️Replace it with a larger MOV 
 
On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue? - ️️Suicide Circuit 
 
You ...
-
Mechanics Exam Review-NEIEP 213 Questions with 100% Correct Answers | Updated | Guaranteed A+
- Tentamen (uitwerkingen) • 23 pagina's • 2024
- Ook in voordeelbundel
-
- $8.49
- + meer info
A contractor wants to raise the car speed from 100 fpm to 125 fpm, it currently has a 12" sheave. What is required? - ️️100 fpm/125 fpm= 12"/ X =15 
 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - ️️Replace it with a larger MOV - 630 
 
On a Ward-Leonard circuit the brake is set, but the motor is trying to slip through the brake. What is the issue? - ️️Suicide Circuit - 425 
 
You have an old DC motor and are ad...
-
Elevator Mechanic Exam Review | 100% Correct Answers | Verified | Latest 2024 Version
- Tentamen (uitwerkingen) • 22 pagina's • 2024
-
- $10.49
- + meer info
A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What 
sheave is required? - Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What 
should you do? - Replace it with a larger MOV 
On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the 
issue? - Suicide Circuit 
You have an old DC motor ...
-
Elevator Mechanic Exam Review Questions and Answers 2024 Correctly done
- Tentamen (uitwerkingen) • 21 pagina's • 2024
- Ook in voordeelbundel
-
- $7.99
- + meer info
A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" sheave. What 
sheave is required? - Answer-Diam=12" 12/4=3" 25fpm=3" 100fpm + 25fpm= 12"+3"= 15" sheave 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What 
should you do? - Answer-Replace it with a larger MOV 
On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the 
issue? - Answer-Suicide Circuit 
You ...
-
Elevator Mechanic Exam Review With Verified And Complete Test Exam
- Tentamen (uitwerkingen) • 17 pagina's • 2023
-
Ook in voordeelbundel
-
- $15.49
- + meer info
Elevator Mechanic Exam Review With Verified And 
Complete Test Exam 
A contractor wants to raise the car speed from 100fpm to 125fpm, it currently has a 12" 
sheave. What sheave is required? Correct Answer: Diam=12" 12/4=3" 25fpm=3" 
100fpm + 25fpm= 12"+3"= 15" sheave 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or 
resistance. What should you do? Correct Answer: Replace it with a larger MOV 
On a Ward-Leonard circuit the break is set, but the motor is ...
-
Neiep review 1 || A Verified A+ Pass.
- Tentamen (uitwerkingen) • 7 pagina's • 2024
-
Ook in voordeelbundel
-
- $10.99
- + meer info
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? correct answers Replace it with a larger MOV 
 
On a Ward-Leonard circuit the break is set, but the motor is trying to slip through the break. What is the issue? correct answers Suicide Circuit 
 
You have an old DC motor and are adding an SCR drive, what do you do to the interpoles? correct answers Leave the interpoles alone. When adding a SCR drive to the generator, the series loo...
-
NEIEP Mechanics Training Exam With All Complete Answers 2024.
- Tentamen (uitwerkingen) • 21 pagina's • 2024
-
Ook in voordeelbundel
-
- $8.39
- + meer info
A contractor wants to raise the car speed from 100 fpm to 125 fpm, it currently has a 12" sheave. What is required? - Answer 100 fpm/125 fpm= 12"/ X =15 
 
A MOV (Metal Oxide Varistor) burns out. You replace it, but cannot read voltage or resistance. What should you do? - Answer Replace it with a larger MOV - 630 
 
On a Ward-Leonard circuit the brake is set, but the motor is trying to slip through the brake. What is the issue? - Answer Suicide Circuit - 425 
 
You have an old DC motor a...