Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

SPI PRACTICE EXAM.docx

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
06-05-2024
Geschreven in
2023/2024

The typical frame rate of an Ultrasound system is? - correct answer Between 30 Hz and 100 Hz Temporal resolution is synonymous with frame rate. Typical frame rates in imaging systems are 30-100 Hz. - correct answer The temporal resolution or frame rate = 1/(time to scan 1 frame). Frame rate can drop down to 5 Hz. Pulse duration is related to bandwidth how? - correct answer Pulse Duration = 1 / Bandwidth Specular reflectors have physical dimensions that are what size in relation to the wavelength? - correct answer Greater Two identical systems produce a pulse. One pulse is 0.8 usec in duration while the other is 1.4 usec. The best radial resolution will be created by which system? - correct answer 0.8 Pulse duration (length of pulse) With a short pulse duration we have a small pulse length. The shorter the SPL the better the longitudinal resolution. To achieve better depth (axial) resolution. You must have what? - correct answer FEWER CYCLES PER PULSE -Axial resolution = SPL / 2 or # cycles in the pulse x wavelength / 2 - correct answer Ultrasound wave attenuation is denoted by which units? - correct answer dB (DECIBELS) If it takes 1/20 of a second to construct a single frame, what is the current frame rate? - correct answer 20 hz--Hz = cycles per second. The rate is 1/20th of a second. So 20 cycles per second = 20 Hz With a focused ultrasound beam, bioeffects...? - correct answer Are less likely to occur The smaller the beam the less likelihood of cavitation. Exam duration has the greatest effect on patient exposure. - correct answer Bioeffects intensity limit: SPTA 100 mW/cm2 Unfocused 1 W/cm2 or 1000 mW/cm2 Focused HIGHEST output intensities used with pulsed doppler. - correct answer Lowest output intensities are with gray-scale imaging. With which type of array are grating lobes most common? - correct answer Linear array Which equation is used to find the doppler shift? - correct answer Fd = 2 Fi v / c In standard diagnostic imaging instrumentation, which has the higher numerical value? - correct answer Lateral Resolution-LATA= higher numerical value LARD = smaller value Reflectors that are closer together than the width of the beam create what artifact? - correct answer Pulse Width artifact-Also known as lateral resolution artifact and beam width artifact. Basically they are shown as a single point because the resolution of the image - correct answer is only as good as the minimal thickness of the beam at that depth. As a wave propagates, the period will? - correct answer Not Change As the operator increases the maximum imaging depth the Pulse Repetition Period (PRP)...? - correct answer Increases--As you image deeper you have to wait longer for the signal to come back so you send less pulses per second. So as you increase the depth you increase the time, you increase the PRP. Brightness of the display is affected by? - correct answer Receiver Amplification Comet tail artifact is produced by? - correct answer Strong reflectors and high propagation speeds. If the propagation speed of a medium is less than soft tissue, where will the resulting echo be placed? - correct answer Deeper than it actually is. The following characteristic is true of all waves. - correct answer They carry energy from one site to another. If the thickness of the 2 substances forming the interface is increased then the amount of beam reflected is...? - correct answer Unchanged-Reflection = (Z2 - Z1)/(Z2 + Z1) Thickness of the medium isn't involved in this equation. Mirror image artifact manifests the associated anatomic structure how? - correct answer Always deeper on the produced image than physically in the body. The period of the wave is proportional to the wavelength how? - correct answer Reciprocal--The longer the wave length, the longer it takes to complete a wave. So if the wavelength goes up the period goes up. - correct answer If the wavelength goes up the frequency goes down, because it just can't make as many. At the focus the ultrasound beam is ______ ? - correct answer where the optimal transverse resolution is located. The beam is narrowest at the focus. Therefore it will have the best ______. - correct answer lateral resolution and the highest intensity.

Meer zien Lees minder
Instelling
SPI
Vak
SPI









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
SPI
Vak
SPI

Documentinformatie

Geüpload op
6 mei 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€7,57
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kan je een ander document kiezen. Je kan het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
rickysparkyy

Maak kennis met de verkoper

Seller avatar
rickysparkyy Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
2 jaar
Aantal volgers
0
Documenten
843
Laatst verkocht
1 maand geleden
Ricky sparky

Ace Your Exams with Our Comprehensive Exam Documents and Answers! Struggling with exam preparation? Look no further! Our expertly crafted exam documents come complete with accurate answers, helping you study efficiently and effectively. Each document is designed to cover key topics, provide clear explanations, and offer insightful answers to typical exam questions. Perfect for students aiming to excel, our materials are regularly updated to align with the latest curriculum standards. **Why Choose Us?** - Accurate and Reliable: Verified answers you can trust. - Comprehensive Coverage: Detailed documents covering all major topics. - Time-Saving: Study smarter, not harder. - User-Friendly Format: Easy to navigate and understand. Achieve academic success with our top-notch study aids. Get started today and ace your exams with confidence! Feel free to modify it to better fit your specific offerings!

Lees meer Lees minder
0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen