Dell EMC PowerEdge Corrective Maintenance 2024
Dell EMC PowerEdge Corrective Maintenance 2024 A mini-PERC RAID Controller requires replacement. What are the steps taken to ensure the RAID controller is installed properly? Angle the mini-PERC card so that one end of the card engages with the cardholder on the system board. Next, ensure the guide pins are aligned to the cable and the mini-PERC. Lastly, secure the two screws, being careful to not overtighten Following the PowerEdge naming convention, which generation does the M830 server belong to? 13G When installing two NVMe drives in a DSS8440 system, two slots are dedicated for NVMe drive installation. Which slots are they? Click the correct highlighted section, then Submit. 8,9 While on a call to service a PowerEdge server, the reported issue is intermittent. The ability to stream real-time events and data logs is instrumental in diagnosing the problem. To successfully stream real-time metrics, the customer must have the correct iDRAC license installed. Which one of the iDRAC licenses enables this feature? Express There was an unexpected system shutdown due to a sudden power outage on a customer system. The data could be expected to be retained by which of the following type of memory? NVDIMM What is the minimum space required on a USB Key to create a Support Live Image (SLI)? 4GB Which of the following is not an ability of the ePSA? To run the Easy Restore after the system board replacement. To add a Host Bus Adapter (HBA) to the system board, which server component could be used? Peripheral Riser Card The image shows the front view of the PowerEdge MX7000. Identify the compute sleds in the system. Click the correct highlighted section, then Submit. [Check online for photo] The PSU LED of a DSS 7000 flashes green five times then turns off. What could this indicate? PSU mismatch. During the installation of a processor, select the caution tips to follow. Select two options that apply. Ensure the protective cover is present and rightly secured. Do not touch the processor- sensitive contacts during installation. A collection of Server Event Logs (SEL) must be extracted and sent to the Technical Support team for troubleshooting using the Dell SupportAssist Collection utility. In the iDRAC GUI below, which tab contains the Dell SupportAssist feature? Click the correct highlighted section, then Submit. Maintenance What is the correct sequence of steps to run the ePSA through the Dell EMC Lifecycle Controller? <F10> -> Hardware Diagnostics -> Run Hardware Diagnostics Which one of the following software is used to manage/monitor PowerEdge servers remotely? iDRAC Which of these functionalities can be performed by a PowerEdge RAID Controller? Select two options that apply. Physically replace a failed drive, without powering off the server. Expand an existing array to include additional drives. The image below shows the rear view of the Dell PowerEdge MX7000 enclosure. Identify the Management Module(s) in the system. Click the correct highlighted section, then Submit. [Check online for photo] What accelerator cards does the DSS8440 support? Select two options that apply. Graphcore C2 cards NVIDIA Tesla V100 The image below shows an iDRAC Dashboard. Which of these sections can be used to access a remote server using the vKVM on your management station? Click the correct highlighted section, then Submit. Virtual Console A customer wants to customize their company logo across the system management software portals instead of the Dell logo. Which feature is suited for this purpose? OEM Identity Module When installing a TPM chip on a system board, which one of the following statements about the TPM are true? By default, the TPM is always turned off in the BIOS Blower modules in servers help to ensure proper cooling of the server modules. Identify the location of the blower modules in the VRTX system shown below. Click the correct highlighted section, then Submit. [check online for photo] During a system board replacement, a new TPM is installed. What is the next best step to take? Insert the TPM chip into the TPM connector and press down on the security rivet/plastic bolt until the bolt snaps into place. After a system board replacement and using Easy Restore, what is automatically restored? System Service Tag OEM/ PM ID While onsite to replace a failed PSU, post installing the replacement PSU and connecting the power cable, it is noticed that the LEDs on the PSU blink green five times, then off. What does this indicate? PSU mismatch, due to mixing of PSUs of older generations in incompatible servers. While onsite at a customer location, it is determined the processor in the Processor and Heatsink Module (PHM) must be replaced. What are the steps to remove the processor from the PHM? Click and drag the steps into the correct sequence, then click Submit. 1. Place the heat sink on a workbench with the processor side facing up. 2. Insert a flat blade screwdriver into the release slot and twist the screwdriver (do not pry). 3. Push the retaining clips on the processor bracket to unlock the bracket from the heatsink. 4. Lift the bracket and the processor away from the heatsink and place the processor connector side down on the processor tray. 5. Flex the outer edges of the bracket to release the processor from the bracket. Which one of these components provides data redundancy for storage? Internal Dual SD Module (IDSDM) An onsite technician at a customer site installed a PERC 10 card in an R630 server. The first time the server booted, the customer was unable to see the drives. The customer restarted the server a second time. This time, the server is not booting at all. An issue with the installation of an unsupported PERC card is suspected. What is the next best step to take? Reseat the card. If problem remains, then call Technical Support.
École, étude et sujet
- Établissement
- Dell Client Foundations
- Cours
- Dell Client Foundations
Infos sur le Document
- Publié le
- 29 mars 2024
- Nombre de pages
- 4
- Écrit en
- 2023/2024
- Type
- Examen
- Contient
- Questions et réponses
Sujets
-
dell emc poweredge corrective maintenance 2024
-
a mini perc raid controller requires replacement
-
following the poweredge naming convention which g
-
while on a call to service a poweredge server the
Document également disponible en groupe