Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Otro

Over Current Protection Using Instantaneous Overcurrent Relay

Puntuación
-
Vendido
-
Páginas
25
Subido en
29-08-2022
Escrito en
2021/2022

Relays are employed in a power system network to ensure that the system operates safely, reliably, and conveniently. The Over-Current relay is commonly utilized in the power system to prevent against short circuits and incorrect system settings. In the power system, an incorrectly set Over-Current relay makes it harder to send the trip signal. As a result, it must be carefully linked in the power system. As a result, it is critical to certify the installation of power protection equipment. The operation of over-current relays, such as instantaneous over-current relays, definite time over-current relays, and inverted definite time over-current relays, is described in this work. A power system network was modelled using the Matlab/Simulink package to quantify the performance of over-current relays using the instantaneous over-current relay. A three-phase 132 kV at 50 Hz source, a 132/11 kV step down transformer, and a single parallel RLC load with active and reactive power of 50 MW and 25 Mvar respectively made up the power system network. The Matlab/Simulink package was used to create the relay block, which had a current setting of 125 percent, a CT of 400/5, a pickup current of 6.25 A, and a time multiplier setting of 0.6. A second RLC parallel load was connected to the network to quantify the relay's performance. The load's active and reactive power were set to 0.3 kW and 0.3 kVar, respectively, and the measured output current was 5.18 A, which was below the pickup current and the relay did not send a trip signal to the circuit breaker. Another parallel RLC load was connected to the network, with the active and reactive power of the first two loads set to 50 kW and 20 kVar, respectively, and the third load's active and reactive power set to 50 MW and 20 Mvar. The output current was measured at 69.5 kA, which is significantly higher than the pickup current, thus the relay detected the problem and sent a trip signal to the circuit breaker.

Mostrar más Leer menos
Institución
Grado

Vista previa del contenido

SCHOOL OF ELECTRICAL, ELECTRONIC AND COMPUTER ENGINEERING




Power Systems 2
(ENEL4WA)
Assignment 2 – Over Current Protection Using
Instantaneous Overcurrent Relay


NOTE// IF YOU NEED SIMULATION FILE EMAIL ME
AT:

,Abstract
Relays are employed in a power system network to ensure that the system operates safely, reliably,
and conveniently. The Over-Current relay is commonly utilized in the power system to prevent
against short circuits and incorrect system settings. In the power system, an incorrectly set Over-
Current relay makes it harder to send the trip signal. As a result, it must be carefully linked in the
power system. As a result, it is critical to certify the installation of power protection equipment. The
operation of over-current relays, such as instantaneous over-current relays, definite time over-current
relays, and inverted definite time over-current relays, is described in this work. A power system
network was modelled using the Matlab/Simulink package to quantify the performance of over-
current relays using the instantaneous over-current relay. A three-phase 132 kV at 50 Hz source, a
132/11 kV step down transformer, and a single parallel RLC load with active and reactive power of
50 MW and 25 Mvar respectively made up the power system network. The Matlab/Simulink package
was used to create the relay block, which had a current setting of 125 percent, a CT of 400/5, a pickup
current of 6.25 A, and a time multiplier setting of 0.6. A second RLC parallel load was connected to
the network to quantify the relay's performance. The load's active and reactive power were set to 0.3
kW and 0.3 kVar, respectively, and the measured output current was 5.18 A, which was below the
pickup current and the relay did not send a trip signal to the circuit breaker. Another parallel RLC
load was connected to the network, with the active and reactive power of the first two loads set to 50
kW and 20 kVar, respectively, and the third load's active and reactive power set to 50 MW and 20
Mvar. The output current was measured at 69.5 kA, which is significantly higher than the pickup
current, thus the relay detected the problem and sent a trip signal to the circuit breaker.




Page | i

, Table of Contents
Abstract..................................................................................................................................................i
Table of figures.....................................................................................................................................iii
Nomenclature........................................................................................................................................v
1. Introduction.......................................................................................................................................1
2. Theoretical Background.....................................................................................................................2
2.1. Fault and its clarification.............................................................................................................2
2.1.1. Symmetrical faults...............................................................................................................2
2.1.2. Unsymmetrical faults...........................................................................................................2
2.2. Requirements of a protection system.........................................................................................2
2.2.1. Reliability.............................................................................................................................2
2.2.2. Selectivity.............................................................................................................................2
2.2.3. Sensitivity.............................................................................................................................2
2.2.4. Speed...................................................................................................................................3
2.2.5. Simplicity..............................................................................................................................3
2.2.6. Economy..............................................................................................................................3
2.3. Protection using relay.................................................................................................................3
2.4. Overcurrent Relay.......................................................................................................................3
2.5. Types of overcurrent relays........................................................................................................4
2.5.1. Instantaneous Overcurrent Relay........................................................................................4
2.5.2. Definite Time Overcurrent Relay..........................................................................................4
2.5.3. Inverse Definite Minimum Time (IDMT) Overcurrent Relay.................................................5
3. Simulations........................................................................................................................................6
3.1. Part 1 – Source, transformer and load voltage and current measurements...............................6
3.1.1. Source..................................................................................................................................7
3.1.2. Transformer.........................................................................................................................8
3.1.3. Load...................................................................................................................................10
3.2. Part 2 - Instantaneous relay block diagram...............................................................................11
3.3. Part 3 – Connecting 2nd load with no over current condition....................................................14
3.4. Part 4- Connecting 3rd load with over-current condition...........................................................15
4. Results discussion and analysis........................................................................................................17
4.1. Part 1 - Source, transformer and load voltage and current measurements..............................17
4.1.1. Source................................................................................................................................17


Page | ii

Escuela, estudio y materia

Institución
Grado

Información del documento

Subido en
29 de agosto de 2022
Número de páginas
25
Escrito en
2021/2022
Tipo
OTRO
Personaje
Desconocido

Temas

$9.20
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
nkanyisontombela

Conoce al vendedor

Seller avatar
nkanyisontombela UKZN
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
3 año
Número de seguidores
1
Documentos
13
Última venta
3 año hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes