ASSE 15000 PRACTICE TEST 3 QUESTIONS AND CORRECT VERIFIED ANSWERS |LATEST VERSION |ALREADY GRADED A+

Document preview thumbnail
Vista previa 2 fuera de 15 páginas

ASSE 15000 PRACTICE TEST 3 QUESTIONS AND CORRECT VERIFIED ANSWERS |LATEST VERSION |ALREADY GRADED A+

Vista previa del contenido

ASSE 15000 PRACTICE TEST 3 QUESTIONS AND CORRECT
VERIFIED ANSWERS |LATEST VERSION |ALREADY
GRADED A+



High priming water levels can adversely affect the operation of supervisory air.
What is not a step in testing the water level? - ANS -Close the priming level test
valve before air discharges


The _____ valve shall be supervised closed in the pipeline to the hose valve
header - ANS -control


A diesel fuel storage tank is required to always be a minimum of __ full. - ANS -2/3


A fire pump controller shall be in a fully functional state within ___ seconds of AC
power available. - ANS -10


The standpipe system demand shall include 500 gpm for the first standpipe and
___ gpm for each additional standpipe until the total system demand is
simultaneously met. - ANS -250


Water motor gongs and pressure switch alarm devices shall be inspected: - ANS -
quarterly


A temporary standpipe used during construction must be at least ___ in diameter
- ANS -4 inches

, Blue color coding on a sprinkler indicates it has a temperature rating between
_____. - ANS -250 - 300 degrees F


When swapping out pressure gauges, it is important to verify the arrow on the 3-
way valve is pointed in the proper direction before removing the gauge and once
the gauge is removed, the 3-way valve must be flushed adequately so any debris
that may have accumulated does not end up in the new gauge. - ANS -True


According to NFPA 20, a _____ refill valve shall be used for each water supply tank
used for fire protection. - ANS -automatic


All sprinkler pressure-reducing valves shall be inspected qurterly to verify the
valves are in the following condition except: - ANS -in the closed position


Which type of pipe is not approved for standpipes - ANS -CPVC


Foam concentrate strainers shall be inspected: - ANS -quarterly


A fire pump water supply must be ___. - ANS -Adequate and dependable


The shut-off head shall not exceed ___ of rated head for any pump. - ANS -140%


The top hose outlet in a buuilding under construction must be maintained within
_____ floors of the highest forms, staging and similar combustibles at all times. -
ANS -one

Información del documento

Subido en
5 de marzo de 2026
Número de páginas
15
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Lectcaptain
5.0
(1)
Vendido
4
Seguidores
0
Artículos
987
Última venta
3 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes