ACTUAL QUESTIONS AND CORRECT
ANSWERS
Recommended General Parameters to be Reported - CORRECT ANSWER EEG
derivations
EOG Derivations
EMG
Leg EMG
Airflow Signal
Respiratory effort signals
oxygen saturation
Body position
ECG (electrocardiogram)
Recommended sleep scoring data to be reported - CORRECT ANSWER Lights out
Lights on
TST
TRT
Sleep Latency
Stage R latency
WASO
Percent sleep efficiency
Time in each stage
Percent of TST in each stage
Recommended Arousal events to be reported - CORRECT ANSWER Number of
arousals
Arousal index( # of arousals x 60/TST)
, Recommended Cardiac events to be reported(If Observed) - CORRECT
ANSWER average heart rate during sleep
highest heart rate during sleep
highest heart rate during recording
Bradycardia, report lowest HR
Asystole, report longest pause
Sinus tachycardia, report highest HR
narrow complex tachy, report report highest HR
wide complex tachy, report highest HR
A-Fib, report average HR
Other Arrhythmias, list arrythmia
Recommended Movement events to be reported - CORRECT ANSWER Number of
PLMS
Number of PLMS with arousals
PLMS Index (plmsx60/TST)
PLMS Arousal index(PLMS with arousalsx60/TST)
Recommended Respiratory events to be reported - CORRECT ANSWER # of
obstructive apneas
# of mixed apneas
# of central apneas
# of hypopneas
# of obstructive hypops
# of central hypops
# of apneas+hypops
Apnea Index
Hypopnea Index
Apnea-Hypopnea Index