CT TEST REVIEW QUESTIONS AND ANSWERS 100% ACCURATECT TEST REVIEW QUESTIONS AND ANSWERS 100% ACCURATECT TEST REVIEW QUESTIONS AND ANSWERS 100% ACCURATE Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT examination? A. Topogram B. Scout C. Scanogram D. Spiral - ANSWER-D. Spiral The ability of a system to differentiate, on the image, objects with similar densities is known as: A. High contrast resolution B. Low contrast resolution C. Spatial resolution D. Temporal resolution - ANSWER-B. Low contrast resolution Each two dimensional square of data that make up the CT image is called a: A. Pixel

Content preview

CT TEST REVIEW QUESTIONS AND
ANSWERS 100% ACCURATE
Which is NOT a synonym for the preliminary/localizer image taken at the start of a CT
examination?
A. Topogram
B. Scout
C. Scanogram
D. Spiral - ANSWER-D. Spiral

The ability of a system to differentiate, on the image, objects with similar densities is
known as:
A. High contrast resolution
B. Low contrast resolution
C. Spatial resolution
D. Temporal resolution - ANSWER-B. Low contrast resolution

Each two dimensional square of data that make up the CT image is called a:
A. Pixel
B. Voxel
C. Matrix
D. Fragment - ANSWER-A. Pixel

How many pixels are contained in a 1,024 matrix image? A. 1,024
B. 2,048
C. 262,144
D. 1,048,576 - ANSWER-D. 1,048,576

Beam attenuation can be defined as:
A. The phenomenon by which artifacts result when lower energy photons are
preferentially absorbed, leaving only higher-intensity photons to strike the detector
array.
B. Xray energy that is produced from bombarding a substance with fast moving
electrons.
C. The ability of the detector to capture transmitted photons and change them to
electronic signals.
D. The phenomenon by which an xray beam passing through a structure is decreased
in intensity or amount because of absorption and interaction with matter. - ANSWER-D.
The phenomenon by which an xray beam passing through a structure is decreased in
intensity or amount because of absorption and interaction with matter.

Which of the following is a low attenuation structure:
A. Iodine filled aorta

,B. Rib
C. Trachea
D. Calcified arteries - ANSWER-C. Trachea

An object is slightly less dense than water. What is the expected hounsfield
measurement?
A. -940
B. -10
C. 50
D. 850 - ANSWER-B. -10

Why does the administration of iodinated contrast media result in an enhanced image?
A. Iodinated contrast material increases the ability of the enhanced structure to
attenuate the xray beam.
B. Iodinated contrast material decreases the average photon energy of the xray beam;
therefore more photons are absorbed by the patient.
C. The administration of contrast material results in a smaller pixel, thereby increasing
spatial resolution, which results in an enhanced image.
D. - ANSWER-A. Iodinated contrast material increases the ability of the enhanced
structure to attenuate the xray beam.

The xray beam sources for CT produce xray energy that is polychromatic. This means:
A. When viewed by the naked eye, the beam exhibits many different colors.
B. It produce, as a byproduct, a substance known as polychlorinated biphenyl.
C. Photons contained in the beam are all of the same wavelength.
D. The beam comprises photons with varying energies. - ANSWER-D. The beam
comprises photons with varying energies.

An object that appears on the image but is not present in the object scanned is called
a/n:
A. Artifact
B. Anomaly
C. Shadow
D. Ghost - ANSWER-A. Artifact

Which is an advantage of filtering the xray beam?
A. Filtering reduces the anode heat load
B. A filtered beam produces images with substantially less quantum mottle
C. Filtering the beam prevents energy from being converted to heat, therefore 100% of
the energy is converted to xrays.
D. Filtering reduces the radiation dose to the patient. - ANSWER-D. Filtering reduces
the radiation dose to the patient

Scan thickness is primarily important for the part it plays in:
A. Noise reduction
B. The contrast scale

,C. Detector aperture opening
D. Volume averaging - ANSWER-D. Volume averaging

You are working with the radiologist to establish examination protocols for your
department. Which of the following is a logical consideration when determining an
appropriate slice thickness for studies of the internal auditory canal?
A. Because the auditory ossicles are quite small, a thin slice will be necessary to reduce
the chance that volume averaging will obscure their appearance on the image.
B. The appropriate slice thickness will vary considerably from patient to patient.
Therefore, each technologist should be free to adjust the slice thickness as he or she
deems necessary for the particular patient.
C. A slice thickness of 5 to 7mm is adequate because the structures of interest are not
particularly small and the examination is most often ordered as a screening study for
asymptomatic patients.
D. The thickest slice available should be used to reduce the radiation dose to the
corneas. - ANSWER-A. Because the auditory ossicles are quite small, a thin slice will
be necessary to reduce the chance that volume averaging will obscure their appearance
on the image.

How many CT numbers are assigned to each pixel in the image matrix?
A. One half the number of all values recorded from the detector array
B. One
C. The number of HU per pixel is one tenth the display field of view
D. Two values for a 256 matrix; 4 values for a 512 matrix - ANSWER-B. One


Regarding the detectors in the CT system, geometric efficiency is controlled primarily
by:
A. detector material
B. type of photodiode used
C. filtration
D. detector spacing and aperture - ANSWER-D. Detector spacing and aperture

Which of the following is a characteristic of xenon gas detectors?
A. Low efficiency
B. Sensitive to temperature and moisture
C. May exhibit afterglow
D. Also called scintillators - ANSWER-A. Low efficiency

Which component of the CT system converts the electric signal supplied by the
detectors into a digital format?
A. Photodiode
B. Array processor
C. Display processor
D. Analog to digital converter - ANSWER-D. Analog to digital converter

, Which is another name for raw data?
A. Image data
B. Scan data
C. Reconstructed data
D. Displayed data - ANSWER-B. Scan data

When in the anatomic position, the arms are:
A. raised above the head, palms backwards
B. crossed over the chest, palms on opposite shoulders
C. down by the sides, palms forward
D. by the sides, elbows bent, palms backward and resting on hips - ANSWER-C. down
by the sides, palms forward

Which of the following components is NOT housed within the gantry?
A. Three phase generator
B. High-frequency generator
C. Slip rings
D. Xenon gas detectors - ANSWER-A. Three phase generator

All the thousands of bits of data acquired by the CT system with each scan are called?
A. Image data
B. Calibration vectors
C. Raw data
D. Ray sums - ANSWER-C. raw data

The DAS reads each arriving ray and measures how much of the beam has been
attenuated. This is:
A. a ray sum
B. a view
C. back projection
D. a sample - ANSWER-A. a ray sum

In CT image creation using a third generation design, a complete set of ray sums is
known as:
A. convolution equation
B. algorithm
C. spatial frequency filter
D. view - ANSWER-D. view

The power capacity of the generator is listed in:
A. milliamperes (mA)
B. thousand heat units (KHU)
C. million heat units (MHU)
D. kilowatts (kW) - ANSWER-D. kilowatts (kW)

Which of the following describes a slip ring device?

Document information

Uploaded on
September 20, 2025
Number of pages
32
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£15.94

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NursingTutor1
3.9
(460)
Sold
1706
Followers
1073
Items
18493
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions