S12 sprinkler test Exam (Latest 2025/ 2026 Update) Questions and Verified Answers| 100% Correct| Grade A Quiz_________________? Alarm Retarding Devices - Answer An alarm check valve that is exposed to changing water supply pressure needs an alarm retarding device. This is required to prevent false alarms when the check valve clapper is lifted from its seat by a temporary pressure surge. Vane type water flow switches sensitivity can also be adjusted to changing water pressures. Quiz_________________? blue disk - Answer partially out of service- on all fire department connections Quiz_________________? Booster pumps/special service pumps - Answer Booster pumps are sometimes used in sprinkler systems. They small pumps with limited power are usually located in the basement or taking suction from gravity tanks. The booster pump is used when the water pressure available at the highest sprinkler head does not quite meet the needs of the sprinkler system. This small pump increases the water pressure in the sprinkler system until it reaches acceptable levels. The booster pump should not be confused with the fire pump or the jockey pump. Quiz_________________? Curb Valves - Answer Gate valves of the non-indicating type are provided in water distribution systems. Gate valves allow the sprinkler system to be shut off for repairs or maintenance. Such valves are normally a non-rising stem type. They are operated using a special key wrench. A valve box is located over the valve to keep dirt from the valve. The valve box also provides a convenient access point for the valve wrench to the valve nut. A complete record should be made for each valve in the system. This record should include the exact location, the date it was installed, the make, the direction of opening, number of turns to open, and any maintenance that was performed. The control valve for the building may also be on the outside wall or attached to an upright post, known as a post indicator valve (PIV). The building or section of the building controlled by the valve is usually marked on the post. The position of this valve (open or closed) is shown through a telltale opening in the post. On some posts, a padlock must first be opened to release the operating wrench or wheel handle. Quiz_________________? deluge sprinkler system - Answer employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Quiz_________________? DELUGE SPRINKLER SYSTEMS - Answer equipped with open sprinkler heads designed to wet down an entire area involved in a fire. This system is needed when there is danger of a fire rapidly spreading throughout the building. The deluge system will slow down the spread of the fire. Deluge systems are suitable for hazardous occupancies. This includes buildings in which flammable liquids or other hazardous materials are handled or stored. The sprinkler heads in the deluge system are open at all times. Under normal conditions there is no water in the piping. The air in the piping is not under pressure. A closed control valve prevents water from flowing into the system. A fire detection device automatically opens the control valve when a fire is identified. A supervisory device signals when the valve is opened. When the valve is opened water flows into the system. The water is then discharged out all of the sprinkler heads. The water control valve may also be opened manually. Quiz_________________? deluge valve - Answer water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO Quiz_________________? Early suppresion fast response sprinklers - Answer fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards Quiz_________________? extended coverage sprinkler - Answer 400 max square feet discharge

Content preview

and Verified Answers| 100%




Quiz_________________?

Alarm Retarding Devices -

Answer✅

An alarm check valve that is exposed to changing water supply pressure needs an alarm
retarding device. This is required to prevent false alarms when the check valve clapper is
lifted from its seat by a temporary pressure surge. Vane type water flow switches sensitivity
can also be adjusted to changing water pressures.



Quiz_________________?

blue disk -

Answer✅

partially out of service- on all fire department connections



Quiz_________________?

Booster pumps/special service pumps -

Answer✅

Booster pumps are sometimes used in sprinkler systems. They small pumps with limited
power are usually located in the basement or taking suction from gravity tanks. The booster
pump is used when the water pressure available at the highest sprinkler head does not quite
meet the needs of the sprinkler system. This small pump increases the water pressure in the



1

, sprinkler system until it reaches acceptable levels. The booster pump should not be
confused with the fire pump or the jockey pump.



Quiz_________________?

Curb Valves -

Answer✅

Gate valves of the non-indicating type are provided in water distribution systems. Gate
valves allow the sprinkler system to be shut off for repairs or maintenance. Such valves are
normally a non-rising stem type. They are operated using a special key wrench. A valve box
is located over the valve to keep dirt from the valve. The valve box also provides a
convenient access point for the valve wrench to the valve nut. A complete record should be
made for each valve in the system. This record should include the exact location, the date it
was installed, the make, the direction of opening, number of turns to open, and any
maintenance that was performed.

The control valve for the building may also be on the outside wall or attached to an upright
post, known as a post indicator valve (PIV). The building or section of the building
controlled by the valve is usually marked on the post. The position of this valve (open or
closed) is shown through a telltale opening in the post. On some posts, a padlock must first
be opened to release the operating wrench or wheel handle.



Quiz_________________?

deluge sprinkler system -

Answer✅

employing open sprinklers that are attached to a piping system that is connected to a water
supply through a valve that is opened by the operation of a detection system installed in the
same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and
discharges from all sprinklers attached.



Quiz_________________?

DELUGE SPRINKLER SYSTEMS -

Answer✅

equipped with open sprinkler heads designed to wet down an entire area involved in a fire.
This system is needed when there is danger of a fire rapidly spreading throughout the
building. The deluge system will slow down the spread of the fire. Deluge systems are


2

, suitable for hazardous occupancies. This includes buildings in which flammable liquids or
other hazardous materials are handled or stored.

The sprinkler heads in the deluge system are open at all times. Under normal conditions
there is no water in the piping. The air in the piping is not under pressure. A closed control
valve prevents water from flowing into the system. A fire detection device automatically
opens the control valve when a fire is identified. A supervisory device signals when the valve
is opened. When the valve is opened water flows into the system. The water is then
discharged out all of the sprinkler heads. The water control valve may also be opened
manually.



Quiz_________________?

deluge valve -

Answer✅

water supply control valve intended to be operated by actuation of an automatic detection
system that is installed in the same area as the discharge devices. INTENDED USE IS
MANUAL AND AUTO



Quiz_________________?

Early suppresion fast response sprinklers -

Answer✅

fast response sprinkler that is listed for its capability to provide fire suppression of specific
high challenge fire hazards



Quiz_________________?

extended coverage sprinkler -

Answer✅

400 max square feet discharge



Quiz_________________?

extra large orifice sprinklers -

Answer✅

= or > 1 inch less pressure to achieve a given discharge density


3

Document information

Uploaded on
August 11, 2025
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£8.74

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
testsmania
4.6
(7)
Sold
4246
Followers
10
Items
1875
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions