NATE ICE Heat Pump



A correct statement regarding the outdoor coil of a heat pump is that damage may result
if the: - answer--defrost water does not drain from the coil.

A dirty air filter in a heat pump operating in the heating mode could result in: - answer--
excessive head pressure.

A dirty air filter on a heat pump system will result in: - answer--high head pressure in the
heat mode and low suction pressure in the cool mode.

A fan delay can add cooling efficiency by: - answer--operating the indoor blower after
compressor shut-down

A heat pump that uses a piston-type metering device on the indoor coil has a piston with
a larger-than-recommended orifice. This will result in: - answer--low head pressure and
high suction pressure in the cooling cycle.

A new 3-ton heat pump installation has an undersized return air duct. In the heating
mode, the unit will most likely: - answer--go off on high pressure safety.

A technician has just installed a heat pump. It heats satisfactorily, but will not cool. A
possible cause of this problem is the: - answer--indoor check valve is stuck open

An electric furnace has four 5-kW elements that are rated at 240V. The available
voltage to operate the furnace is 208V. Which of the following indicates the effect that
this will have on the BTUH output of the furnace? - answer--it will reduce the BTUH
output of the furnace.

An electric furnace is controlled by a single-stage thermostat. On a call for heat, all
connected circuits function properly; however, the heat rise across the furnace is much
lower than design requirement. Which one of the following actions should the technician
take to correct this problem? - answer--reduce the air volume through the furnace

Coefficient of Performance (COP) is used primarily in the heating/cooling field to
compare heat-pump efficiencies to those of: - answer--electric heating units.

Document information

Uploaded on
July 22, 2025
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
£17.11

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
favouredone
4.4
(352)
Sold
399
Followers
36
Items
10240
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions