MKC SWE Study Material| 300 QUESTIONS|
WITH COMPLETE SOLUTIONS
TCTO
Technical Change Training Order
Non-Self Righting Small Boats less than 65 feet in length for
Changes that create more than a 0.002 ft change in the center of gravity in any direction (vertical,
longitudal or transverse) or net weight changes of more than 1/5 of 1% of the full load
displacement
All other Assets require TCTO for
Changes that create more than a 0.001 ft change in center of gravity (vertical, long, trans) or net
weight changes of more than 1/20 of 1% of the full load displacement require TCTO.
Weight Change Threshold
1/5 of 1% of full load displacement for small boats.
TCTO Requirement for Other Assets
0.001 ft center of gravity change triggers TCTO.
Changes to hull structure, space allocation, watertight integrity or compartmentation
require
TCTO
Change to any system that affects spare parts allowance require
TCTO
Fluid or Paint System Changes require
TCTO
Changes that require Electromagnetic Compatibility EMC or TEMPEST Inspection
require
,TCTO
Form fit or function changes require
TCTO
Changes in software MODS require
TCTO
All cutter and boats operating machine machinery, Shelby inspected how often
Every hour and reading shall be recorded
How often do cutters equipped with video and electronic control systems that monitor
space is for fire and flooding need to be inspected
Every 4 hours
How often should machine machinery be checked in port?
Every four hours
How often should Electrical short ties be inspected?
During the hours of 6 AM to 10 PM
All propulsion machinery shall be attended during
Main engine start, warm up, securing, and during other than normal operating conditions
Coast Guard requires certified welding, brazing, and non-destructive task procedures to
Provide standard across Coast Guard, ensure high-quality welds, provide an adequate level of
safety, develop a valid method to measure knowledge and skill, provide consistent requirements
between organic commercial service providers
All critical welds must be welded by a blank and inspected at a minimum by a blank
Certified Coast Guard welder
Level two non-destructive test qualified INSPECTOR
What is the safety and environmental health manual?
,COMDINST space M5100.47
Coast Guard to float gas, free engineers are not authorized to certified spaces as gas free
for blank
Commercial contract work
Coast Guard, afloat, gas, free engineers, a float, gas, free engineer, petty officers that have
obtained and maintained qualifications are authorized to certify spaces for work only for
who
Coast Guard civilian and DOD persons
EPO must issue how many gas free engine engineering certificates per year to keep
qualifications current
Four
What is alternative maintenance?
Changes to equipment or systems that change the design or design capabilities to improve
inherent, reliability, or functionality
What is availability?
The percent of time that a system is ready for use
What is corrective maintenance?
Maintenance required to restore operation of systems and equipment to design parameters when
functional failure has occurred
What is inherent availability?
The percent of time that a system is theoretically available for use
What is functional failure?
Failure of an item to perform normal of characteristic actions within specified limits
What is maintenance manager?
, Any person responsible for managing alternative, preventative, or corrective maintenance
What is operational availability?
Percent of time operational system is ready for use
What is preventative maintenance?
Actions taken to minimize conditions that causes unacceptable degradation of functions, prior to
the occurrence of actual failure
EAL unscheduled maintenance
AMMIS supply management, ACS configuration management
Unscheduled maintenance without MPC's are documented where
EAL
What does SFLC use to identify trends and potential reliability deficiencies
Supply and demand rates/failure data
What is FRACAS
Failure reporting and corrective action system
What is a time directed task?
Life renewal, regardless of condition
A blank fault safety shorting probe shall be conspicuously located in all engineering spaces
containing switch boards or other installed high-voltage electrical equipment
25,000 V
Do not itemize fuel when using it as a what
Solvent
PD 680, type two flashpoint 140 F and biotech HI SOLV space are available from where
NSS
WITH COMPLETE SOLUTIONS
TCTO
Technical Change Training Order
Non-Self Righting Small Boats less than 65 feet in length for
Changes that create more than a 0.002 ft change in the center of gravity in any direction (vertical,
longitudal or transverse) or net weight changes of more than 1/5 of 1% of the full load
displacement
All other Assets require TCTO for
Changes that create more than a 0.001 ft change in center of gravity (vertical, long, trans) or net
weight changes of more than 1/20 of 1% of the full load displacement require TCTO.
Weight Change Threshold
1/5 of 1% of full load displacement for small boats.
TCTO Requirement for Other Assets
0.001 ft center of gravity change triggers TCTO.
Changes to hull structure, space allocation, watertight integrity or compartmentation
require
TCTO
Change to any system that affects spare parts allowance require
TCTO
Fluid or Paint System Changes require
TCTO
Changes that require Electromagnetic Compatibility EMC or TEMPEST Inspection
require
,TCTO
Form fit or function changes require
TCTO
Changes in software MODS require
TCTO
All cutter and boats operating machine machinery, Shelby inspected how often
Every hour and reading shall be recorded
How often do cutters equipped with video and electronic control systems that monitor
space is for fire and flooding need to be inspected
Every 4 hours
How often should machine machinery be checked in port?
Every four hours
How often should Electrical short ties be inspected?
During the hours of 6 AM to 10 PM
All propulsion machinery shall be attended during
Main engine start, warm up, securing, and during other than normal operating conditions
Coast Guard requires certified welding, brazing, and non-destructive task procedures to
Provide standard across Coast Guard, ensure high-quality welds, provide an adequate level of
safety, develop a valid method to measure knowledge and skill, provide consistent requirements
between organic commercial service providers
All critical welds must be welded by a blank and inspected at a minimum by a blank
Certified Coast Guard welder
Level two non-destructive test qualified INSPECTOR
What is the safety and environmental health manual?
,COMDINST space M5100.47
Coast Guard to float gas, free engineers are not authorized to certified spaces as gas free
for blank
Commercial contract work
Coast Guard, afloat, gas, free engineers, a float, gas, free engineer, petty officers that have
obtained and maintained qualifications are authorized to certify spaces for work only for
who
Coast Guard civilian and DOD persons
EPO must issue how many gas free engine engineering certificates per year to keep
qualifications current
Four
What is alternative maintenance?
Changes to equipment or systems that change the design or design capabilities to improve
inherent, reliability, or functionality
What is availability?
The percent of time that a system is ready for use
What is corrective maintenance?
Maintenance required to restore operation of systems and equipment to design parameters when
functional failure has occurred
What is inherent availability?
The percent of time that a system is theoretically available for use
What is functional failure?
Failure of an item to perform normal of characteristic actions within specified limits
What is maintenance manager?
, Any person responsible for managing alternative, preventative, or corrective maintenance
What is operational availability?
Percent of time operational system is ready for use
What is preventative maintenance?
Actions taken to minimize conditions that causes unacceptable degradation of functions, prior to
the occurrence of actual failure
EAL unscheduled maintenance
AMMIS supply management, ACS configuration management
Unscheduled maintenance without MPC's are documented where
EAL
What does SFLC use to identify trends and potential reliability deficiencies
Supply and demand rates/failure data
What is FRACAS
Failure reporting and corrective action system
What is a time directed task?
Life renewal, regardless of condition
A blank fault safety shorting probe shall be conspicuously located in all engineering spaces
containing switch boards or other installed high-voltage electrical equipment
25,000 V
Do not itemize fuel when using it as a what
Solvent
PD 680, type two flashpoint 140 F and biotech HI SOLV space are available from where
NSS