• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Start selling Create your account
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

Advanced PLCs Test 1: Module 1-3 Exam Questions and Answers 100% Pass

Document preview thumbnail
Preview 2 out of 5 pages

Advanced PLCs Test 1: Module 1-3 Exam Questions and Answers 100% Pass PLCs provide a means of controlling machines and other industrial application with a(n) ___________________ instead of using hard wired devices. - ANS industrial computer A PLC requires much less _____ than a hard wired relay panel that could do the same job. - ANS space The six basic components of most PLCs are the power supply, the input and output modules, the processors module, the programming device, and the ___________. - ANS I/O chassis A(n) __________ network is a high speed communications connection used to exchange data between production line equipment and other devices within a manufacturing facility. - ANS industrial The three network levels are Enterprise, Automation and _______, and Field Device. - ANS Control _______________ uses several protocols to convert data from its native format, such as a text message, into a format that can be sent and tracked from the source node to the destination node of a network. - ANS Ethernet TCP/IP Ethernet/IP uses the ___ (protocol) to produce a network suitable for use on automation and control level. - ANS CIP

Content preview

©FYNDLAY 2025 ALL RIGHTS RESERVED




Advanced PLCs Test 1: Module 1-3 Exam
Questions and Answers 100% Pass




PLCs provide a means of controlling machines and other industrial application with a(n)
___________________ instead of using hard wired devices. - ANS industrial computer


A PLC requires much less _____ than a hard wired relay panel that could do the same job. -
ANS space


The six basic components of most PLCs are the power supply, the input and output modules,
the processors module, the programming device, and the ___________. - ANS I/O chassis


A(n) __________ network is a high speed communications connection used to exchange data
between production line equipment and other devices within a manufacturing facility. -
ANS industrial


The three network levels are Enterprise, Automation and _______, and Field Device. -
ANS Control


_______________ uses several protocols to convert data from its native format, such as a text
message, into a format that can be sent and tracked from the source node to the destination
node of a network. - ANS Ethernet TCP/IP


Ethernet/IP uses the ___ (protocol) to produce a network suitable for use on automation and
control level. - ANS CIP


©FYNDLAY 1

, ©FYNDLAY 2025 ALL RIGHTS RESERVED




A PLC and PC are connected in a(n) ______________ network using a single Ethernet cable. -
ANS point-to-point


Two addresses are used for Ethernet communications: Media Access Control (MAC) and
______________________. - ANS Internet Protocol (IP)


_______ are software programs that allow a device to connect to a network and communicate
with other devices. - ANS Drivers


The IP address of a CompactLogix PLC that already has an IP address is viewed and edited using
______ communications software. - ANS RSLinx


The basic operation of a(n) ___ is to scan instructions, monitor the status of input devices, and
produce outputs based on which inputs are on or off. - ANS PLC


All PLCs must have a(n) ______________________ to operate. - ANS user developed project


A(n) __ is used to download hardware configurations and programs to a PLC. - ANS PC


A() _______ is a file that contains a hardware configuration and control program. -
ANS project


__________ is a network search utility that shows the layout of every network that has a driver
configured in RSLinx. - ANS Who Acitve


The 1769-L16ER controller's USB port is USB ___ compatible and operates at 12 Mbps. -
ANS 2.0


________ is an embedded operating system that controls how microprocessor-controlled
hardware devices operate. - ANS Firmware

©FYNDLAY 2

Document information

Uploaded on
May 5, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
£8.55

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay
3.7
(78)
Sold
437
Followers
82
Items
21773
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions