Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

IBHRE EXAM

Rating
-
Sold
-
Pages
124
Grade
A+
Uploaded on
07-02-2025
Written in
2024/2025

Exam of 124 pages for the course IBHRE at IBHRE (IBHRE EXAM)

Institution
Module

Content preview

IBHRE EXAM, PRACTICE EXAM AND STUDYGUIDE NEWES
m m m m m m


T 2025 ACTUAL EXAM COMPLETE 400 QUESTIONS AND CO
m m m m m m m m


RRECT DETAILED ANSWERS (VERIFIED ANSWERS)
m m m m


|ALREADY GRADED A+ m m




A function of pacemaker circuitry that allows the pacemaker output puls
m m m m m m m m m m


e to be dissipated quickly maximizing both the output and sensingcapabi
m m m m m m m m m m m


lities.

a) circuit resistors m


b) charge dump m


c) pulse neutralizer m


d) current consumption - ANSWER B. Charge Dump
m m m m m m




AV sequentially paced patients with frequent ventricular ectopy should
m m m m m m m m m


have the following pacemaker parameters programmed to decrease the
m m m m m m m m m


chance of competition:
m m




a) short blanking period m m


b) slower base rate m m


c) increased ventricular refractory period m m m


d) none of the above - ANSWER A. Short Blanking Period
m m m m m m m m m




Low threshold electrode materials include each of the following
m m m m m m m m m


EXCEPT:

a) iridium oxide m


b) elgiloy
c) platinized platinum m


d) titanium nitride - ANSWER B. Elgiloy m m m m m




The strength duration curve resulting in a parabolic shape is described
m m m m m m m m m m m


by which of the following formulas?
m m m m m

,a) I x t m m


b) I x V x t
m m m m


c) I x R m m


d) all of the above - ANSWER B. I x V x t
m m m m m m m m m m m




The ventriculoatrial conduction time of a pacemaker patient with a typic
m m m m m m m m m m


al endless-loop-tachycardia may be calculated by which equation?
m m m m m m m




a) (upper rate limit interval) - ( AV delay + PVARP)
m m m m m m m m m


b) (upper rate limit interval) - m m m m


m( AV delay + PVARP + Wenckebachinterval
m m m m m m m


c) (lower rate limit interval) - ( upper rate limit interval)
m m m m m m m m m


d) none of the above - ANSWER D. None of the above
m m m m m m m m m m




Which of the following programmings would not prevent crosstalk?
m m m m m m m m




a) a prolonged blanking period
m m m


b) "safety pacing" m


c) low atrial output m m


d) less sensitive ventricular sensitivity -
m m m m




m ANSWER B. "Safety Pacing"The most commonly used battery chem
m m m m m m m m m




istry in ICDs is:
m m m




a) lithium thionyl chloride m m


b) lithium manganese dioxide m m


c) lithium silver vanadium oxide m m m


d) lithium manganese dioxide - m m m


mANSWER C. Lithium Silver VanadiumOxide m m m m m




The purpose of a capacitor in an electrical circuit is to:
m m m m m m m m m m




a) convert AC to DC current m m m m


b) store electrical charge
m m


c) rapidly switch battery voltage on or off
m m m m m m

,d) limit current flow to a single direction -
m m m m m m m


ANSWER B. Store ElectricalCharge
m m m m m




A programming mode that would NOT be utilized to manage interm
m m m m m m m m m m


ittent atrial fibrillation in a patient with a DDD pacemaker is:.
m m m m m m m m m m




a) DDI
b) DVI
c) VDD
d) VVI - ANSWER C. VDD m m m m




Variations in stimulus morphology on the surface ECG of an analogreco
m m m m m m m m m m m


rder may be caused by:
m m m m




a) a dislodged electrode
m m


b) an electrical short
m m


c) changes in patient position m m m


d) all of the above - ANSWER D. All of the above
m m m m m m m m m m




All of the following have been used as ERI magnet responses except:
m m m m m m m m m m m




a) abrupt increase in rate m m m


b) abrupt decrease in rate m m m


c) gradual increase in rate m m m


d) gradual decrease in rate - ANSWER C. Gradual Increase In Rate
m m m m m m m m m m




Which of the following has not been used as an indicator of battery
m m m m m m m m m m m m m


depletion?

a) pulse width stretching m m


b) mode change m


c) programmed amplitude reversion m m


d) telemetered battery impedance - m m m


mANSWER C. ProgrammedAmplitude Reversion m m m m

, The electrical circuit that converts a signal with both positive and
m m m m m m m m m m m


negative components into a signal with only one component?
m m m m m m m m




a) resistor
b) rectifier
c) diode
d) capacitor - ANSWER B. Rectifier m m m m




Which of the following would account for the most common cause of
m m m m m m m m m m m m


inappropriate mode switching? m m




a) ventricular lead sensing atrial signals m m m m


b) lead insulation breakm m


c) oversensing EMI m


d) atrial lead sensing ventricular signals -
m m m m m


mANSWER D. Atrial LeadSensing Ventricular Signals
m m m m m m




A patient's stimulation threshold was 1.0 Volt & 0.4 msec pulse duratio
m m m m m m m m m m m


n. The pacemaker is programmed to 2.0 Volt & 0.8 msec duration. Lead
m m m m m m m m m m m m


mimpedance measures 1000 Ohms. The output energy forthis patient wou
m m m m m m m m m m


ld be: m




a) 2X threshold m


b) 4X threshold m


c) 6X threshold m


d) 8X threshold - ANSWER D. 8x Threshold
m m m m m m




Factors which might increase the time until activation of the EBU
m m m m m m m m m m m


(emergency back- m


up) or stat set and which would be avoided whenutilizing temporar
m m m m m m m m m m m


y programming include:
m m




a) breaking of the telemetry link m m m m


b) reinitialization of the EBU or stat set m m m m m m


c) having to locate the EBU actuation mechanism
m m m m m m


d) all of the above - ANSWER D. All of the above
m m m m m m m m m m

Written for

Module

Document information

Uploaded on
February 7, 2025
Number of pages
124
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£14.40
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorsectionn Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
34
Member since
1 year
Number of followers
2
Documents
842
Last sold
2 months ago
EXCELLENT HOMEWORK

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that\'s why i\'m one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Read more Read less
4.8

747 reviews

5
616
4
96
3
21
2
8
1
6

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions