Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 9 pages
Exam (elaborations)

EPA 608 Guaranteed Success

Document preview thumbnail
Preview 2 out of 9 pages

EPA 608 Guaranteed Success 1. Definition of Reclaiming: - To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis defines: ️ Reclaiming. 2. Disposable Cylinder Disposal Method: - The proper disposal method for disposable cylinders is to ️ recover any remaining refrigerant and then render the cylinder useless, then recycle the metal. 3. Definition of Recycling: - Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or more filter driers is the definition of: ️ Recycle. 4. GWP of R-1234ze: - The Global Warming Potential (GWP) of R-1234ze is ️ 0. 5. Hydrostatic Testing Frequency: - Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ️ Every 5 years. 6. Venting Off Refrigerant Vapor: - When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off the top must be ️ recovered. 7. Example of Non-condensable: - An example of a non-condensable is ️ air. 8. Vacuum System Safety: - When a system is in deep vacuum, never ️ energize the compressor. 9. HC Refrigerant for Small Appliances: - The HC refrigerant allowed for use in new domestic small appliances is ️ R-600a. 10. Leak Rate Repair Requirement: - Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches ️ 30% or more. 11. Refrigerant Trace Gas Release: - What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found? ️ Release into atmosphere. 12. Classification of Common Refrigerants: - Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ️ A1. 13. Evacuation Level for R-410A: - When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ️ 0" Hg. 14. Dehydration Level: - When dehydrating a system, it should be evacuated to a level of ️ 500 microns. 15. Condensing and Refrigerant Recovery: - Refrigerant should be recovered from the condenser outlet if the condenser is ️ below the receiver. 16. Action for Non-Repairable Leaking Appliance: - If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ️ retrofitted or retired within 12 months. 17. Recovery Level for Medium Pressure System: - When recovering a medium pressure system with more than 200 lbs of refrigerant, recover to a level of: ️ 15" Hg. 18. Standard for Machine Room Safety: - The standard for machine room safety is ️ ASHRAE 15. 19. Safety Classification of HCFC-123: - The safety classification of HCFC-123 is ️ B1. 20. EPA Evacuation Level for Low Pressure Systems: - The EPA required evacuation level for recovery or recycling equipment used on low-pressure systems is ️ 25 mm of Hg absolute. 21. Equipment for Type III Certification: - What type of equipment can be worked on with Type III certification? ️ Low pressure. 22. Safety Classification of R-134A: - The safety classification of R-134A under ASHRAE Standard 34 is ️ A1. 23. Rupture Disk Burst Pressure: - The rupture disk on a low-pressure chiller has a burst pressure of ️ 15 psig. 24. Maximum Pressure for Leak Detection: - When pressurizing a low-pressure system for leak detection purposes, do not exceed ️ 10 psig. 25. Oil Used in HFC and HFO Systems: - The oil used in HFC and HFO HVACR systems is ️ Esters.

Content preview

EPA 608 Guaranteed Success


1. Definition of Reclaiming:

- To process refrigerant to a level equal to new (virgin) product specifications as determined by
chemical analysis defines: ✔️ Reclaiming.



2. Disposable Cylinder Disposal Method:

- The proper disposal method for disposable cylinders is to ✔️ recover any remaining refrigerant and
then render the cylinder useless, then recycle the metal.



3. Definition of Recycling:

- Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or
more filter driers is the definition of: ✔️ Recycle.



4. GWP of R-1234ze:

- The Global Warming Potential (GWP) of R-1234ze is ✔️ 0.



5. Hydrostatic Testing Frequency:

- Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ✔️
Every 5 years.



6. Venting Off Refrigerant Vapor:

- When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off
the top must be ✔️ recovered.



7. Example of Non-condensable:

- An example of a non-condensable is ✔️ air.



8. Vacuum System Safety:

- When a system is in deep vacuum, never ✔️ energize the compressor.

, 9. HC Refrigerant for Small Appliances:

- The HC refrigerant allowed for use in new domestic small appliances is ✔️ R-600a.



10. Leak Rate Repair Requirement:

- Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or
greater when the annualized leak rate reaches ✔️ 30% or more.



11. Refrigerant Trace Gas Release:

- What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found?
✔️ Release into atmosphere.



12. Classification of Common Refrigerants:

- Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ✔️ A1.



13. Evacuation Level for R-410A:

- When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ✔️
0" Hg.



14. Dehydration Level:

- When dehydrating a system, it should be evacuated to a level of ✔️ 500 microns.



15. Condensing and Refrigerant Recovery:

- Refrigerant should be recovered from the condenser outlet if the condenser is ✔️ below the
receiver.



16. Action for Non-Repairable Leaking Appliance:

- If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ✔️
retrofitted or retired within 12 months.

Document information

Uploaded on
August 6, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
£8.66

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1
4.4
(5)
Sold
18
Followers
0
Items
1369
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions