ASE T6 TEST |ACTUAL QUESTIONS AND VERIFIED
ANSWERS|BRAND NEW 2026-2027
UPDATE|GRADED A+


Question 1

A resistance test was performed on an open toggle switch and the result is 5.857
megohms . Technician A says that the switch is faulty because the reading is beyond the
specifications . Technician B says that the switch has over 5 million ohms of resistance .
Who is correct ?

A. A only

B. B only

C. Both A and B

D. Neither A nor B

CORRECT ANSWER

Answer A is incorrect . An open switch is supposed to have very high resistance .

Answer B is correct . Only Technician B is correct . The reading is over 5 million ohms . An
open switch should have very high resistance .

Answer C is incorrect . Only Technician B is correct .

Answer D is incorrect . Technician B is correct .




Question 2

The 12 volt battery in the figure is fully charged and the switch is closed . Which of the
following conditions would be the most likely cause of this measurement ?

A. Larger than specified wire used in wire repair

B. Loose ground for the bulb

C. Blown fuse

D. Faulty bulb

CORRECT ANSWER


1

,Answer A is incorrect . A larger wire used in a wire repair would not cause a voltage loss .

Answer B is correct . A loose ground for the bulb could cause a voltage loss at the ground
connection . Performing a voltage drop test on the ground circuit could isolate this problem .

Answer C is incorrect . A blown fuse would prevent any voltage from getting past the fuse
contacts .

Answer D is incorrect . There is no evidence that the bulb is faulty . The meter shows only 9
volts being dropped across the bulb .




Question 3

Which of the following conditions could cause the power locks to fail to operate ? A.
Broken connector at the power lock switch

B. Closed power lock circuit breaker

C. An oversized fuse

D. An oversized wire repair in the power lock circuit

CORRECT ANSWER

Answer A is correct . A broken connector at the power lock switch could cause the power
locks to be inoperative because it would likely create an open circuit .

Answer B is incorrect . A closed power lock circuit breaker would allow normal operation of
the power door locks .

Answer C is incorrect . An oversized fuse would allow the power door locks to function . For
safety reasons , however , a technician should never install a fuse that has a larger rating
than the specification .

Answer D is incorrect . An oversized wire would not hinder the operation of the power door
locks .




Question 4

When using a 12 volt , unpowered test lamp to test for voltage , all of the following are
true EXCEPT : A. The test lamp may be connected to the battery ground .



2

, B. The battery should first be disconnected .

C. The test lamp may be connected to a chassis ground . D. The test lamp will not illuminate
when probed into the circuit at a point after the load .

CORRECT ANSWER

Answer A is incorrect . A 12 volt unpowered test lamp can be connected to the battery
ground cable or any quality ground on the truck .

Answer B is correct . The test light would not operate if the battery were disconnected .
Answer C is incorrect . A 12 volt unpowered test lamp can be connected to the chassis
ground or any quality ground on the truck .

Answer D is incorrect . The voltage level will drop to near zero at points past the load ,
causing the test lamp to not illuminate if probed into this part of the circuit.




Question 5

After removing a 30 amp circuit breaker from a fuse panel , a technician checks continuity
across its terminals with a digital multimeter ( DMM ) . Technician A says that the current
from the ohmmeter will open the circuit breaker . Technician B says the ohmmeter should
read infinity if the circuit breaker is good . Who is correct ?

A. A only

B. B only

C. Both A and B

D. Neither A nor B

CORRECT ANSWER

Answer A is incorrect . The small amount of current supplied by an ohmmeter would not
cause a good circuit breaker to open up . Answer B is incorrect . The ohmmeter should read
low resistance on a good circuit breaker

Answer C is incorrect . Neither Technician is correct .

Answer D is correct . Neither Technician is correct . Using an ohmmeter to test a circuit
breaker will not cause the contacts to open up because the current from the meter will be
very small . A good circuit breaker will have a low reading when being tested with an
ohmmeter .



3

Document information

Uploaded on
September 27, 2026
Number of pages
30
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
£11.27

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
THESTUDYVAULT
3.4
(20)
Sold
161
Followers
6
Items
14463
Last sold
21 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions