R 410a CERTIFICATION |ACTUAL QUESTIONS AND
VERIFIED ANSWERS|BRAND NEW 2026-2027
UPDATE|GRADED A+
Question 1
R-410A is also known as:
A Suva 410a
B AZ-20
C Puron
D All of the above
CORRECT ANSWER
D All of the above
Question 2
The temperature glide for R-410A is less than ___________ degrees F over air conditioning
and refrigeration operating ranges:
A 0.3
B 0.9
C 1.0
D 1.5
CORRECT ANSWER
A 0.3
Question 3
Both suction and discharge pressures of R-410A systems are ___________ than R-22:
1
,A The same
B 40% to 70% higher
C 60% lower
D 10% to 30% higher
CORRECT ANSWER
B 40% to 70% higher
Question 4
When a blend is zeotropic, or near-azeotropic(NARM):
A Leaks may cause a change in the composition of the blend
B It will have temperature glide
C It can fractionate
D All of the above
CORRECT ANSWER
D All of the above
Question 5
A true azeotropic blend:
A Will not fractionate
B Has no temperature glide
C Behaves as a single component refrigeration
D All of the above
CORRECT ANSWER
D All of the above
2
, Question 6
When installing a liquid line filter drier on an R-410A system, be certain it has a rating of:
A 500 psig
B 600 psig
C 700 psig
D 800 psig
CORRECT ANSWER
B 600 psig
Question 7
Subcooled liquid in the receiver may ___________ subcooling, depending on the
surrounding conditions:
A Lose
B Gain
C Either "A" or "B"
D Neither "A" or "B"
CORRECT ANSWER
C Either "A" or "B"
Question 8
Because of its higher vapor heat capacity, the discharge temp. of R-410A is ___________
than R-22:
A Higher
B Lower
C The same
3
VERIFIED ANSWERS|BRAND NEW 2026-2027
UPDATE|GRADED A+
Question 1
R-410A is also known as:
A Suva 410a
B AZ-20
C Puron
D All of the above
CORRECT ANSWER
D All of the above
Question 2
The temperature glide for R-410A is less than ___________ degrees F over air conditioning
and refrigeration operating ranges:
A 0.3
B 0.9
C 1.0
D 1.5
CORRECT ANSWER
A 0.3
Question 3
Both suction and discharge pressures of R-410A systems are ___________ than R-22:
1
,A The same
B 40% to 70% higher
C 60% lower
D 10% to 30% higher
CORRECT ANSWER
B 40% to 70% higher
Question 4
When a blend is zeotropic, or near-azeotropic(NARM):
A Leaks may cause a change in the composition of the blend
B It will have temperature glide
C It can fractionate
D All of the above
CORRECT ANSWER
D All of the above
Question 5
A true azeotropic blend:
A Will not fractionate
B Has no temperature glide
C Behaves as a single component refrigeration
D All of the above
CORRECT ANSWER
D All of the above
2
, Question 6
When installing a liquid line filter drier on an R-410A system, be certain it has a rating of:
A 500 psig
B 600 psig
C 700 psig
D 800 psig
CORRECT ANSWER
B 600 psig
Question 7
Subcooled liquid in the receiver may ___________ subcooling, depending on the
surrounding conditions:
A Lose
B Gain
C Either "A" or "B"
D Neither "A" or "B"
CORRECT ANSWER
C Either "A" or "B"
Question 8
Because of its higher vapor heat capacity, the discharge temp. of R-410A is ___________
than R-22:
A Higher
B Lower
C The same
3