California Alarm Company Qualified Manager (ACQ) Exam Bank Questions
with Verified Answers | Latest Update


Question 1: Under the California Alarm Company Act (Business and Professions Code Section 7590 et
seq.), within how many days must an Alarm Company Operator (ACO) notify the Bureau of Security
and Investigative Services (BSIS) of any change in its qualified manager?

A. 10 days

B. 30 days

C. 45 days

D. 60 days

CORRECT ANSWER: B. 30 days

Rationale: Pursuant to Business and Professions Code Section 7594.3, an alarm company operator must
report any change of a qualified manager to the Bureau of Security and Investigative Services (BSIS) in
writing within 30 days of the change. Failure to notify the bureau within this timeframe can result in
administrative fines or license suspension.

Question 2: According to BSIS regulations, what is the minimum age requirement for an applicant
seeking to qualify as a designated Qualified Manager for an Alarm Company Operator license?

A. 18 years old

B. 21 years old

C. 25 years old

D. There is no age requirement as long as experience criteria are met

CORRECT ANSWER: A. 18 years old

Rationale: California Business and Professions Code Section 7592.1 specifies that an applicant for an
Alarm Company Qualified Manager certificate must be at least 18 years of age, pass a background check,
and demonstrate two years of verified qualifying experience in the alarm industry.

Question 3: What is the primary difference between a hardwired supervised initiating device circuit
(IDC) Class A and Class B wiring configuration in fire and intrusion alarm systems?

A. Class A circuits require wireless backup transmitters, whereas Class B circuits use only physical wire
runs.

,B. Class A circuits include a redundant return path allowing operational capability during a single open
fault, whereas Class B circuits do not.

C. Class B circuits operate at 120VAC, while Class A circuits operate at 24VDC power levels.

D. Class B circuits use End-of-Line (EOL) resistors at the panel, while Class A circuits do not use resistors
anywhere in the system.

CORRECT ANSWER: B. Class A circuits include a redundant return path allowing operational capability
during a single open fault, whereas Class B circuits do not.

Rationale: Class A wiring provides a redundant signaling path returning back to the control units,
allowing the circuit to transmit an alarm signal even if a single open or ground fault occurs on the line.
Class B circuits lack this return loop, meaning a single open fault will disable device reporting
downstream of the break.

Question 4: Which California state regulatory agency is directly responsible for licensing, regulating,
and disciplining Alarm Company Operators and Qualified Managers?

A. California Contractors State License Board (CSLB)

B. Department of Industrial Relations (DIR)

C. Bureau of Security and Investigative Services (BSIS)

D. California Department of Forestry and Fire Protection (CAL FIRE)

CORRECT ANSWER: C. Bureau of Security and Investigative Services (BSIS)

Rationale: The Bureau of Security and Investigative Services (BSIS), a division of the California
Department of Consumer Affairs (DCA), governs the licensing and enforcement of Alarm Company
Operators (ACO), Qualified Managers (ACQ), and registered Alarm Agents under the Alarm Company Act.

Question 5: What component is required on a secondary power supply battery installation to prevent
thermal runaway and overcharging in an alarm control panel?

A. Step-down transformer

B. Temperature-compensated battery charger

C. High-pass inductive filter

D. Line isolation monitor

CORRECT ANSWER: B. Temperature-compensated battery charger

,Rationale: NFPA guidelines and standard alarm engineering principles require charging systems to adjust
charging voltage based on ambient temperature. A temperature-compensated battery charger prevents
battery overcharging, thermal runaway, and premature degradation in standby power supplies.

Question 6: Under California law, how long must an Alarm Company Operator maintain employee
records, including employee registration applications and background verification documents, after
the termination of employment?

A. 1 year

B. 2 years

C. 3 years

D. 5 years

CORRECT ANSWER: C. 3 years

Rationale: Business and Professions Code Section 7599.36 dictates that an Alarm Company Operator
must maintain complete records of all employees, including their registration applications and personnel
records, for at least two to three years depending on record type, with 3 years being the required
retention baseline for general personnel records and proof of registration status.

Question 7: What is the purpose of an End-of-Line (EOL) resistor in a conventional intrusion alarm zone
loop?

A. To lower current draw to preserve primary battery life during standby mode

B. To allow the control panel to supervise the wiring integrity for open and short circuit conditions

C. To step down the voltage from 24VDC to 12VDC for motion detectors

D. To absorb high-voltage lightning surges coming from outdoor alarm devices

CORRECT ANSWER: B. To allow the control panel to supervise the wiring integrity for open and short
circuit conditions

Rationale: An EOL resistor creates a measurable reference current in the zone loop. By placing the
resistor at the end of the line, the panel can detect a drop in current (indicating an open circuit or broken
wire) or a rise in current (indicating a short circuit across the wires), providing supervised circuit
monitoring.

Question 8: In accordance with National Fire Alarm and Signaling Code (NFPA 72), what is the
minimum required backup standby battery capacity for a commercial protective premises fire alarm
system?

A. 12 hours of standby power plus 5 minutes of alarm notification power

, B. 24 hours of standby power plus 5 minutes of alarm notification power

C. 48 hours of standby power plus 15 minutes of alarm notification power

D. 72 hours of standby power plus 30 minutes of alarm notification power

CORRECT ANSWER: B. 24 hours of standby power plus 5 minutes of alarm notification power

Rationale: NFPA 72 specifies that secondary power supplies for protected premises fire alarm systems
must operate the system under normal non-alarm conditions for at least 24 hours and, at the end of that
period, be capable of operating all required notification appliances for at least 5 minutes (or 15 minutes
for emergency voice communications).

Question 9: What administrative action must a Qualified Manager take if an alarm agent employee
commits a violation of the Alarm Company Act resulting in arrest or criminal conviction?

A. Immediately cancel the company's operating license until an internal audit is finished

B. Submit written notification to BSIS within 30 days detailing the circumstances

C. Fire the employee immediately without keeping any records

D. Report the violation exclusively to local law enforcement

CORRECT ANSWER: B. Submit written notification to BSIS within 30 days detailing the circumstances

Rationale: Alarm Company Operators and Qualified Managers are required to notify BSIS in writing
within 30 days regarding disciplinary actions, arrests, or convictions involving registered alarm agents
working under their management.

Question 10: Which type of motion detector technology utilizes the Doppler shift principle to detect
moving targets within a secured space?

A. Passive Infrared (PIR)

B. Dual-technology Photoelectric

C. Microwave Detector

D. Glassbreak Acoustic Sensor

CORRECT ANSWER: C. Microwave Detector

Rationale: Microwave motion sensors emit high-frequency radio waves and measure the frequency shift
of the reflected waves (Doppler effect) caused by a moving object. Passive Infrared (PIR) sensors, by
contrast, measure changes in thermal radiation patterns.

Document information

Uploaded on
September 19, 2026
Number of pages
70
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
£13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorExpert
3.7
(81)
Sold
614
Followers
315
Items
11095
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions