◉ When the pump is in operation a small water leak on the pump
bearings is desirable and should not be considered a malfunction.
Additionally, water should discharge from a ---- relief valve (electric
pump) or --- exchanger (diesel pump) while the fire pump is operating
under a "no-flow" condition. Answer: circulation /heat


◉ A sprinkler system is a Answer: fire extinguishing system, other than
a water mist system, that utilizes water as the extinguishing agent.


◉ Inspection, testing, servicing and other maintenance of sprinkler
systems must be Answer: personally supervised and be performed in
accordance with NFPA (National Fire Protection Association) #25 2011
edition.


◉ All multiple dwellings, factories, office buildings, warehouses, stores
and offices, theaters and music halls, hospitals and asylums, and all
public schools and other public buildings, churches and other places
where large numbers of persons are congregated for purposes of
worship, instruction, amusement, and all piers, bulkheads, wharves, pier
sheds, bulkhead sheds or other waterfront structures shall provide
Answer: fire extinguishers, buckets, axes, fire hooks, fire doors and

,other means of preventing and extinguishing fires as the commissioner
may direct.


◉ Required fire protection systems shall be extended or altered as
necessary to maintain and continued protection whenever Answer: the
building or structure is altered. Systems not complying with this section
shall be considered to be impaired.


◉ It shall be unlawful to install or maintain any fire protection system or
device that has Answer: the physical appearance of fire protection
equipment but that does not perform a fire protection function where it
may be confused with actual fire protection equipment. An example
would be a CCTV camera that is installed inside a shell that resembles a
sprinkler head


◉ SPRINKLER AND/OR STANDPIPE SYSTEM MAINTENANCE
AND INSPECTIONS Answer:


◉ 1. Automatic and non-automatic sprinkler systems shall be inspected,
tested and maintained as required by NFPA #25 2011 edition by a
competent person holding a S-12 Certificate of Fitness and employed or
contracted by the owner, to see that all parts of the system are in good
working order, and that the Fire Department connection(s), if any, are
ready for immediate use by the Fire Department. A detailed record shall
be kept on the premises or other approved location, for a minimum of 3
years for examination by any representative of the Fire Department.
Answer:

,◉ 2.A supply of at least six extra sprinkler heads shall be kept available
on the premises, to replace promptly any fused or damaged sprinklers.
Any head which has opened or has been damaged shall be replaced
immediately with sprinkler head of similar characteristics such as
operating temperature, orifice size, deflector orientation and thermal
sensitivity. Answer:


◉ 3. At least once every five years, the Fire Department connection or
connections for a sprinkler system shall be subjected to a hydrostatic
pressure test to demonstrate its suitability for Fire Department use. The
test shall be arranged to be conducted by a Master Fire Suppression
Piping Contractor in the presence of a Fire Department representative.
The contractor shall be hired by the owner or the owner's representative.
Answer:


◉ 4.There shall be one or more employees or individuals contracted by
the owner with a Certificate of Fitness to inspect the sprinkler system
following the standard of the NFPA 25 of 2011. Answer:


◉ Automatic and non-automatic sprinkler systems shall be inspected,
tested and maintained as required by NFPA #25 2011 edition by
Answer: competent person holding a S-12 Certificate of Fitness and
employed or contracted by the owner, to see that all parts of the system
are in good working order, and that the Fire Department connection(s), if
any, are ready for immediate use by the Fire Department.

, ◉ A detailed record shall be kept on the premises or other approved
location, for a minimum of Answer: 3 years for examination by any
representative of the Fire Department.


◉ A supply of at least----extra sprinkler heads shall be kept available on
the premises, to replace promptly any fused or damaged sprinklers.
Answer: 6


◉ Any head which has ----or has been----1. shall be replaced
immediately with sprinkler head of similar characteristics such as
operating temperature, orifice size, deflector orientation and thermal
sensitivity. Answer: opened/damaged


◉ At least once every ---- years Answer: Fire Department connection or
connections for a sprinkler system shall be subjected to a hydrostatic
pressure test to demonstrate its suitability for Fire Department use.


◉ At least once every five years, the Fire Department connection or
connections for a sprinkler system shall be subjected to a hydrostatic
pressure test to demonstrate its suitability for Fire Department use. The
test shall be arranged to be conducted by a ----by a----The contractor
shall be hired by----- Answer: Master Fire Suppression Piping
Contractor/1. a Fire Department representative/the owner or the owner's
representative.


◉ There shall be---more employees or individuals contracted by the
owner with a----Certificate of Fitness 1. inspect the sprinkler system
following the standard of the NFPA 25 of 2011. Answer: one/COF

Document information

Uploaded on
August 18, 2026
Number of pages
112
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
£12.16

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GradeGalaxy
4.2
(13)
Sold
162
Followers
4
Items
53901
Last sold
19 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions