Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 40 pages
Exam (elaborations)

TDLR TEXAS GENERAL PUMP INSTALLER PRACTICE EXAM BANK: 185 VERIFIED QUESTIONS WITH DETAILED RADICAL RATIONALES

Document preview thumbnail
Preview 4 out of 40 pages

TDLR TEXAS GENERAL PUMP INSTALLER PRACTICE EXAM BANK: 185 VERIFIED QUESTIONS WITH DETAILED RADICAL RATIONALES Construction / Pump Installation / Water Well Drilling / Electrical System Exam coverage: I. Section A (Q1-30): Texas Laws and Rules – TAC Chapter 76, licensing requirements, endorsements, experience, renewal, penalties. II. Section B (Q31-45): Hydraulics and Pump Theory – TDH, friction loss, NPSH, cavitation, pump curves, water horsepower. III. Section C (Q46-75): Installations and Repair – Submersible and jet pump installation, short-cycling, troubleshooting, torque arrestors, VFDs. IV. Section D (Q76-100): Electrical Systems – Wiring, voltage drop, NEC, grounding, VFDs, lockout/tagout. V. Section E (Q101-130): Tools and Equipment – Pipe cutters, torque wrenches, pressure gauges, multimeters, pitless adapters. VI. Section F (Q131-150): Exam Statistics – Pass rates, candidate numbers, topic scores. VII. Section G (Q151-180): Additional Pump Knowledge – Pump curves, well abandonment, pump sizing, pressure tanks. Page 2 of 40 VIII. Section H (Q181-185): Safety and OSHA – Fall protection, confined space, PPE, chemical safety

Content preview

Page 1 of 40


TDLR TEXAS GENERAL PUMP INSTALLER PRACTICE EXAM
BANK: 185 VERIFIED QUESTIONS WITH DETAILED RADICAL
RATIONALES


Construction / Pump Installation / Water Well Drilling / Electrical System



Exam coverage:
I. Section A (Q1-30): Texas Laws and Rules – TAC Chapter 76,
licensing requirements, endorsements, experience, renewal,
penalties.
II. Section B (Q31-45): Hydraulics and Pump Theory – TDH,
friction loss, NPSH, cavitation, pump curves, water
horsepower.
III. Section C (Q46-75): Installations and Repair – Submersible
and jet pump installation, short-cycling, troubleshooting,
torque arrestors, VFDs.
IV. Section D (Q76-100): Electrical Systems – Wiring, voltage
drop, NEC, grounding, VFDs, lockout/tagout.
V. Section E (Q101-130): Tools and Equipment – Pipe cutters,
torque wrenches, pressure gauges, multimeters, pitless
adapters.
VI. Section F (Q131-150): Exam Statistics – Pass rates,
candidate numbers, topic scores.
VII. Section G (Q151-180): Additional Pump Knowledge – Pump
curves, well abandonment, pump sizing, pressure tanks.

, Page 2 of 40


VIII. Section H (Q181-185): Safety and OSHA – Fall protection,
confined space, PPE, chemical safety



SECTION A: TEXAS LAWS AND RULES (TAC 76) (Questions 1-
30)

1. Which Texas agency regulates water well pump installers?
A. Texas Commission on Environmental Quality (TCEQ)
B. Texas Department of Licensing and Regulation (TDLR) ✓
C. Texas Water Development Board (TWDB)
D. Texas Department of Agriculture

CORRECT: B
RATIONALE: TDLR regulates water well pump installers under
Texas Occupations Code Chapter 1901 .

2. A person may NOT act or offer to act as a pump installer
unless the person is:
A. A registered plumber
B. Licensed by TDLR ✓
C. A certified well driller
D. A professional engineer

CORRECT: B
RATIONALE: A person may not act or offer to act as a driller or
pump installer unless licensed by TDLR .

, Page 3 of 40


3. Which Texas Administrative Code chapter governs water
well pump installers?
A. Chapter 34
B. Chapter 76 ✓
C. Chapter 120
D. Chapter 190

CORRECT: B
RATIONALE: TAC Chapter 76 regulates water well drillers and
water well pump installers .

4. How many years of experience are required to qualify for a
pump installer license?
A. 1 year
B. 2 years ✓
C. 3 years
D. 4 years

CORRECT: B
RATIONALE: Applicants must have the required two (2) years of
experience installing pumps .

5. How many documented pump installations are required
for each endorsement?
A. 5
B. 10
C. 15 ✓
D. 20

, Page 4 of 40


CORRECT: C
RATIONALE: Applicants must have sufficient installation
experience, requiring 15 installations for each pump
endorsement .

6. The "General Pump Installer" license allows an installer to
perform work on:
A. Only single-phase pumps
B. All types of pumps including single-phase, three-phase,
and line-shaft turbine pumps ✓
C. Only residential pumps
D. Only submersible pumps

CORRECT: B
RATIONALE: The General Pump Installer endorsement covers
all pump types .

7. Pump installer licenses in Texas must be renewed every:
A. 1 year
B. 2 years ✓
C. 3 years
D. 5 years

CORRECT: B
RATIONALE: Pump installer licenses must be renewed every 2
years .

8. To qualify for the "General Pump Installer" exam, an
applicant must have:

Document information

Uploaded on
August 14, 2026
Number of pages
40
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
£15.85

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
55
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions