CUSP-T&D 2025 LATEST EXAM QUESTIONS AND ALL
CORRECT CORRECT 100%ANSWERS 100% SOLVED
AND GUARANTEED TO PASS CONCEPTS...GRADED A+
As per CAN/ULC S801, on an electrical distribution overhead utility line circuit,
verification of voltage absence can be achieved by: - CORRECT 100%ANSWER-
Using an approved voltage detector.
Isolation and tagging (no locks) is acceptable on an overhead distribution
circuit under some of the following conditions, EXCEPT for: - CORRECT
100%ANSWER-The isolation can be operated from the ground directly at the
base of a structure.
Isolation and tagging (no locks) is acceptable for an overhead distribution
circuit under some of the following conditions: - CORRECT 100%ANSWER-1. The
isolation point is a physical and visual like a line cut or riser removed.
2. The isolation point can only be operated by the operating authority or
qualified worker.
3. The isolation point is protected from unauthorized access such as
vertical height spacing.
Consider that a circuit has been isolated, tagged and grounded. workers
returning the next day must: - CORRECT 100%ANSWER-Visually check grounds to
verify they are in good order, secure and test for voltage.
,For lockout purposes, energy isolating devices shall be labelled or marked using
a standardized nomenclature and format to indicate their function.
Identification shall include: - CORRECT 100%ANSWER-The equipment type,
energy type, and magnitude.
Utilities often use a permitting system due to special circumstances of which
conventional lockout is impracticable. The following is NOT a justified approach
to this process: - CORRECT 100%ANSWER-The isolation points are only simple
single step actions.
A high voltage utility or electrical company is authorized to use Complex
Lockout (tag permitting) under what regulatory condition: - CORRECT
100%ANSWER-A variance application has been approved by the provincial
authority.
Utilities often use a permitting system due to special circumstances of which
conventional lockout is impracticable. The following are justified approaches to
this process: - CORRECT 100%ANSWER-1. The isolation points are located in
remote areas with difficult or restricted access.
2. The length of time to perform the lockout is impracticable.
3. Excessive numbers of persons required to lockout.
Work on a distribution line must consider the following items when performing
isolation and de-energizing of the circuit.: - CORRECT 100%ANSWER-1. Whether
there are multiple sources of energy (loop feed) on the circuit.
2. Is the line isolating device capable of interrupting load.
3. Is the line to be subject to inductive or capacitive charge.
, According to the CAN/ULC S801, what is the LEAST DESIRABLE type of fall
protection: - CORRECT 100%ANSWER-Fall Arrest System (FAS)
Within Z259.14 standards fall restriction equipment (FRE) may only be leather
in subcomponents or elements that are NOT exposed to: - CORRECT
100%ANSWER-A dynamic load.
As per Z259 standards, energy absorbing lanyards shall be classified according
to their ability to absorb the kinetic energy from a fall as follows: -
CORRECT 100%ANSWERClass E4 (4.0 kN) and Class E6 (6.0 kN) energy
absorbing lanyards.
Assuming that the fall protection system is correctly being used, in what
scenario might the worker still contact the ground if they fell: - CORRECT
100%ANSWERWorking 16 feet up in a bucket truck on distribution secondary
services using a six foot shock absorbing lanyard, connected to the approved
bucket anchor.
What is NOT defined as a requirement of temporary vertical life lines as per
Z259 standards: - CORRECT 100%ANSWER-100% polypropylene fibers provide
the greatest breaking strength.
Requirements of temporary vertical life lines, as per Z259 standards: -
CORRECT 100%ANSWER-1. Shall be made from synthetic fibers with breaking
strength of 27 kN or greater.
2. They shall be free of splices and knots, except at the terminations.
3. They shall be installed to protect against abrasion and sharp edges.
CORRECT CORRECT 100%ANSWERS 100% SOLVED
AND GUARANTEED TO PASS CONCEPTS...GRADED A+
As per CAN/ULC S801, on an electrical distribution overhead utility line circuit,
verification of voltage absence can be achieved by: - CORRECT 100%ANSWER-
Using an approved voltage detector.
Isolation and tagging (no locks) is acceptable on an overhead distribution
circuit under some of the following conditions, EXCEPT for: - CORRECT
100%ANSWER-The isolation can be operated from the ground directly at the
base of a structure.
Isolation and tagging (no locks) is acceptable for an overhead distribution
circuit under some of the following conditions: - CORRECT 100%ANSWER-1. The
isolation point is a physical and visual like a line cut or riser removed.
2. The isolation point can only be operated by the operating authority or
qualified worker.
3. The isolation point is protected from unauthorized access such as
vertical height spacing.
Consider that a circuit has been isolated, tagged and grounded. workers
returning the next day must: - CORRECT 100%ANSWER-Visually check grounds to
verify they are in good order, secure and test for voltage.
,For lockout purposes, energy isolating devices shall be labelled or marked using
a standardized nomenclature and format to indicate their function.
Identification shall include: - CORRECT 100%ANSWER-The equipment type,
energy type, and magnitude.
Utilities often use a permitting system due to special circumstances of which
conventional lockout is impracticable. The following is NOT a justified approach
to this process: - CORRECT 100%ANSWER-The isolation points are only simple
single step actions.
A high voltage utility or electrical company is authorized to use Complex
Lockout (tag permitting) under what regulatory condition: - CORRECT
100%ANSWER-A variance application has been approved by the provincial
authority.
Utilities often use a permitting system due to special circumstances of which
conventional lockout is impracticable. The following are justified approaches to
this process: - CORRECT 100%ANSWER-1. The isolation points are located in
remote areas with difficult or restricted access.
2. The length of time to perform the lockout is impracticable.
3. Excessive numbers of persons required to lockout.
Work on a distribution line must consider the following items when performing
isolation and de-energizing of the circuit.: - CORRECT 100%ANSWER-1. Whether
there are multiple sources of energy (loop feed) on the circuit.
2. Is the line isolating device capable of interrupting load.
3. Is the line to be subject to inductive or capacitive charge.
, According to the CAN/ULC S801, what is the LEAST DESIRABLE type of fall
protection: - CORRECT 100%ANSWER-Fall Arrest System (FAS)
Within Z259.14 standards fall restriction equipment (FRE) may only be leather
in subcomponents or elements that are NOT exposed to: - CORRECT
100%ANSWER-A dynamic load.
As per Z259 standards, energy absorbing lanyards shall be classified according
to their ability to absorb the kinetic energy from a fall as follows: -
CORRECT 100%ANSWERClass E4 (4.0 kN) and Class E6 (6.0 kN) energy
absorbing lanyards.
Assuming that the fall protection system is correctly being used, in what
scenario might the worker still contact the ground if they fell: - CORRECT
100%ANSWERWorking 16 feet up in a bucket truck on distribution secondary
services using a six foot shock absorbing lanyard, connected to the approved
bucket anchor.
What is NOT defined as a requirement of temporary vertical life lines as per
Z259 standards: - CORRECT 100%ANSWER-100% polypropylene fibers provide
the greatest breaking strength.
Requirements of temporary vertical life lines, as per Z259 standards: -
CORRECT 100%ANSWER-1. Shall be made from synthetic fibers with breaking
strength of 27 kN or greater.
2. They shall be free of splices and knots, except at the terminations.
3. They shall be installed to protect against abrasion and sharp edges.