●● What does increasing the compression ratio do, and when would you
use this?
Answer: Soft sound gain is unaltered, but gain for moderate/loud sounds
is lowered. Most often used if a PT complains loud/moderate sounds are
too loud or background noise is too loud. ** sometimes you use this on
just certain frequencies, for example, high frequencies if they complain
dishes are too loud, or low frequencies if they complain their voice is
echo-y


●● What happens when you raise a knee point, and when would you do
this?
Answer: You will decrease gain for soft sounds and raise gain for
moderate/loud sounds. Most often used if they hear soft sounds better
than moderate ones ( like hearing the table across from them better than
their own in a restaurant) or when they complain about hearing a HA's
circuit noise.


●● What does lowering the kneepoint do, and when would you do this?
Answer: Lowering the KP will lower gain for moderate and loud sounds,
and increase gain for soft sounds below the original KP. Mostly used
when a PT complains they can't hear soft sounds like soft voices, bird
chirping, or ticking clocks.

,●● What are the two types of compression?
Answer: Input compression - when the input level of a HA determines
when compression is activated.
Output compression - when the output (input + gain) of the HA
determines when compression is activated.


●● What is Wide Dynamic Range Compression?
Answer: (WDRC) This is what most HA's utilize today, and allows the
signal to be packaged withing a user's DR. Typically WDRC HA's have
low (35-55 dB SPL) KPs and low (1:1 - 1:4) ratios


●● What is the Compression Ratio?
Answer: The ratio of change between the input and output of a HA. This
determines how much compression will occur.


●● What is the Kneepoint? (KP)
Answer: The lowest level at which compression is applied


●● What is Harmonic Distortion?
Answer: Harmonic distortion occurs when a single frequency is
presented to the input of a hearing aid and the output contains the
original frequency plus additional undesired frequencies that are
harmonically related to the original frequency.

,ANSI uses a harmonic distortion test that measures the distortion rate at
specific Hz.


●● Frequency Response Curve
Answer: Used in ANSI testing. A gain curve is run with the input sound
at 60 dB SPL to simulate conversation level. You get the frequency
range calculation from this test.


●● Reference Test Gain (RTG)
Answer: Used in ANSI testing. Input sound is set at 60 dB SPL to
simulate conversation level; and then the HFA gain is adjusted to HFA-
OSPL90 -77 dB. The answer is the RTG.


●● Full On Gain (FOG)?
Answer: Used in ANSI testing. The HFA-FOG is measured and recorded
w/ the input set at 50 dB SPL


●● Maximum Output Curve ( OSPL90)
Answer: Used in ANSI testing. It's the max output of a HA. Input is set
to 90 dB SPL to test. Notes the max at each tested frequency. HFA is
noted from this test.


●● What must be done to an aid before ANSI testing?
Answer: 1- Occlude all vents on outside of aid

, 2- Set to test mode with gain full on, output at max, and bandwidth to
max
3-Telecoil should be turned off and only turned back on when testing
SPLITS


●● What couplers do do you use with what instruments when ANSI
testing?
Answer: HA-1 = ITE
SB-1 = RIC and thin tube BTE's
HA-2 = BTE


●● What is a coupler?
Answer: A joiner for a HA that is designed off the vol of an average ear
(2cc). Used to connect the HA to a testing box for ANSI tests.


●● What is Adaptive Feedback Supression?
Answer: This allows a HA to detect and minimize feedback on it's own.


** There is also static feedback supression.


●● What is Digital Noise Reduction (DNR)?
Answer: This is an algorithm which allows a HA to seperate desired
signals ( like speech) from undesired ones ( like noise)

Document information

Uploaded on
May 26, 2026
Number of pages
157
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£10.56

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
FocusFile7
3.9
(24)
Sold
233
Followers
3
Items
60822
Last sold
19 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions