RPSGT EXAM MOCK
RPSGT Certification Mock
Examination 2026 A
Comprehensive Practice
Assessment




enhanced artifact The failure to remove electrode paste residue will MOST likely result in:
a. discarded electrodes.
b. enhanced artifact.
c. improved detergent selection.
d. improvement in adherence.


Initiate emergency response system The most appropriate action a technologist would take when there is confirmed
ventricular tachycardia lasting greater that 30 seconds is:
a. Initiate emergency response system
b. Assess, document and continue to monitor
c. No immediate response is needed
d. Discontinue recording and transport to emergency room


Do not use the equipment until the leakage current is The polysomnograph has a leakage current of 200uA. What should the technician
lowered. do about this?
a. Plug the equipment into an ungrounded plug to avoid a ground loop.
b. Do not use the equipment until the leakage current is lowered.
c. Continue to record since this leakage current is within acceptable limits.
d. Use an extra grounding electrode on the patients


sweat Which of the following conditions are most likely to cause slow wave artifact in
the EEG and EOG channels?
a .Muscle tension
b. Sweat
c. Incorrect placement of the reference electrodes
d. A and C are correct

,c3 The electrode located 30% above the left pre-auricular crease is:
C3
P3
01
F3


hypoventilation CO2 monitoring, using either end-tidal or transcutaneous sensors, is mandatory in
children for the scoring of:
A.
Apnea
B.
Hypopnea
C.
Central events
D.
Hypoventilation


capnography What additional parameter would be MOST helpful to monitor when recording a
patient with COPD?
a. intercostal EMG
b. piezo technology
c. esophageal pressure
d. capnography


DC Which of these channel types produces a square calibration wave?
EEG
EMG
Respiratory
DC


unacceptable leak value The most common reason for changing the PAP interface during titration is:
a. Sustained desaturations
b. Low sleep efficiency
c. Treatment emergent central apneas
d. Unacceptable leak value


3.2 cm The measured distance from the nasion to the inion is 32cm. What is the distance
from the inion to Oz?
1.6cm
3.2cm
6.4cm
16cm


high and unequal electrode impedances Which of the following factors is most likely to cause 60Hz artifact?
a : High and unequal electrode impedance
b. Incorrect low and high frequency filter settings.
c. Incorrect placement of the reference electrodes
d. Direct pressure against one of the electrode

, 5.8cm The circumferential measurements is 58cm. What is the distance between O1 &
O2?
2.4 cm
5.8 cm
10cm
7.2 cm


less than 5k ohms Which of the following are the recommended impedance levels for EEG
electrodes?
a. Less then 20,000 ohms
b. Less then 5 ohms
c. Less then 5k ohms
d. At least 20,000 ohms


arm EMG Which of these electrode sites is not typically used in a baseline montage?
Leg EMG
E2
Arm EMG
Thoracic belt


Recording the differences in the voltages of two inputs Which of the following is a process performed by a differential amplifier?
a. Recording the differences in the voltages of two inputs
b. Recording the differences in the voltages of the active input and ground
c. Recording the differences in the voltages of an exploring electrode and the
patient ground connection
d. Recording only identical voltages received by its two inputs


hunter-cheyne-stokes breathing pattern Adaptive servo ventilation is an effective treatment for which of the following
disorders?
A.
Obesity hypoventilation syndrome
B.
Nocturnal asthma
C.
Hunter-Cheyne-Stokes breathing pattern
D.
Congenital central hypoventilation syndrome


increasing the LFF from 0.3 hz to 1.0 hz All of the following may be helpful in identifying 60-Hz artifact EXCEPT:
a. applying and removing the AC (line) filter.
b. decreasing time base to count the frequency.
c. decreasing the HFF from 70 Hz to 35 Hz.
d. increasing the LFF from 0.3 Hz to 1.0 Hz.


document any changes in recording parameters One of the MOST important roles of the recording technologist is to:
a. score sleep stages prior to applying treatment
b. document any changes in recording parameters
c. record interpretation of patient comments and actions
d. assure patient completes the pre-sleep questionnaire

Document information

Uploaded on
April 24, 2026
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£16.80

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVIAGURU2025
3.7
(75)
Sold
498
Followers
447
Items
1895
Last sold
2 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions