EPA 608 Type 1 2026/2027 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || GUARANTEED PASS 1. Before opening a self contained recovery machine make sure the - ANSWER inlet valve is open, and tank does not contain excessive air (non condensables) 2. The only way to read refrigerant pressure correctly is at - ANSWER a stable known temperature 3. Air in refrigeration systems will cause - ANSWER higher discharge pressures 4. When purging non-condensables abide by - ANSWER operating instruction supplied by equipment manfactuer 5. All refrigerant recovery equipment should be check for what on a daily basis - ANSWER oil level and leaks 6. A system dependent recovery unit has - ANSWER special charcoal activated plastic "bag" containers 7. System dependent equipment captures refrigerant with the assistance of - ANSWER an applicant compressor, external heat source, or vacuum pump 8. A standard vacuum pump can only be used in combination with a - ANSWER non-pressurized container 9. In order to release trapped refrigerant from the compressor oil - ANSWER heat and tap the compressor several times and/ or use a vacuum pump 10. Because appliances with non-operating compressors can not always achieve desired evacuation rates utilizing system dependent equipment - ANSWER The EPA requires at least one self contained recovery device available at the shop 11. The exception to the EPA required rule of a self contained device available is technicians - ANSWER working on small appliances only 12. System dependent devices may only be used on appliances - ANSWER containing 15 lbs. of refrigerant or less. 13. When installing an access fitting onto a sealed system, - ANSWER the fitting should be leak tested before proceeding with recovery. 14. It is generally recommended that _____ ____ type valves be used on only copper or aluminum tubing material, these fitting tend to leak over time and should not be left on a permanent service fixture. - ANSWER Solder-less piercing 15. After installing a access fitting you the system pressure to be 0 PSIG - ANSWER do not begin recovery process. 16. Operating a defrost heater on a domestic frost free refrigerator will help to - ANSWER vaporize any trapped liquid refrigerant and will speed the recovery process. 17. When recovering refrigerant from a system that experienced a compressor burn-out, - ANSWER watch for signs of contamination in the oil. 18. Small appliances may use such refrigerants as __,___,___ and therefore should not be recovered with current using current recovery equipment. - ANSWER Ammonia, Hydrogen, Water 19. the fitting should be leak tested before proceeding with recovery - ANSWER When installing any type of access fitting onto a sealed system; 20. small appliances - ANSWER Any person who opens an appliance for maintenance service or repair must have at least one self-contained recovery machine available at their place of business. The exceptions to this rule are persons working on; 21. MVAC-like system that holds 3 lbs of refrigerant - ANSWER What is NOT a type 1 appliance? 22. restricted to technicians who are EPA certified in refrigerant recovery - ANSWER The sale of CFC and HCFCs are; 23. products manufactured, charged and hermetically sealed in factory and having 5 lbs or less or refrigerant - ANSWER EPA definition of small appliance 24. captures refrigerant in a non-pressurized container - ANSWER The system-dependent (passive) recovery process for small appliances; 25. 75 psig - ANSWER Storage cylinder of recovered R-12 at normal room temperature in the absence of non-condensables, will be pressurized to 26. capable of recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under the conditions of ARI 740 - ANSWER All recovery devices manufactured BEFORE November 15, 1993 27. recovering 90% of the refrigerant when the compressor is operating or achieving a 4 inch vacuum under the ARI 740 - ANSWER Small Appliance recovery equipment manufactured AFTER November 15, 1993 must be certified to be capable of; 28. it is not mandatory to repair the leak but do so whenever possible - ANSWER when servicing a small appliance for a leak repair; 29. When filling a charging cylinder with a regulated refrigerant; - ANSWER The refrigerant vapor that is vented off the top of the cylinder must be recovered. 30. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; - ANSWER Recovery is not required.

Content preview

EPA 608 Type 1 2026/2027 COMPLETE
QUESTIONS WITH CORRECT DETAILED
ANSWERS || GUARANTEED PASS


1. Before opening a self contained recovery machine make sure the -
ANSWER ✅ inlet valve is open, and tank does not contain excessive air
(non condensables)


2. The only way to read refrigerant pressure correctly is at - ANSWER ✅ a
stable known temperature


3. Air in refrigeration systems will cause - ANSWER ✅ higher discharge
pressures


4. When purging non-condensables abide by - ANSWER ✅ operating
instruction supplied by equipment manfactuer


5. All refrigerant recovery equipment should be check for what on a daily basis
- ANSWER ✅ oil level and leaks


6. A system dependent recovery unit has - ANSWER ✅ special charcoal
activated plastic "bag" containers


7. System dependent equipment captures refrigerant with the assistance of -
ANSWER ✅ an applicant compressor, external heat source, or vacuum
pump

, 8. A standard vacuum pump can only be used in combination with a -
ANSWER ✅ non-pressurized container


9. In order to release trapped refrigerant from the compressor oil - ANSWER
✅ heat and tap the compressor several times and/ or use a vacuum pump


10.Because appliances with non-operating compressors can not always achieve
desired evacuation rates utilizing system dependent equipment - ANSWER
✅ The EPA requires at least one self contained recovery device available at
the shop


11.The exception to the EPA required rule of a self contained device available
is technicians - ANSWER ✅ working on small appliances only


12.System dependent devices may only be used on appliances - ANSWER ✅
containing 15 lbs. of refrigerant or less.


13.When installing an access fitting onto a sealed system, - ANSWER ✅ the
fitting should be leak tested before proceeding with recovery.


14.It is generally recommended that _____ ____ type valves be used on only
copper or aluminum tubing material, these fitting tend to leak over time and
should not be left on a permanent service fixture. - ANSWER ✅ Solder-less
piercing


15.After installing a access fitting you the system pressure to be 0 PSIG -
ANSWER ✅ do not begin recovery process.

Document information

Uploaded on
April 12, 2026
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£9.05

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
DrMwendwa
2.0
(2)
Sold
3
Followers
0
Items
480
Last sold
2 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions