Identify FIVE requirements for a 1. An MWS apparatus equipped with a fire pump
MWS apparatus that can be found in must have a tank to pump line at least two inches
in NFPA 1901 diameter and be capable of supplying the
pump
with 500 GPM until at least 80% of the tank is
emptied.
2.An MWS apparatus must be equipped with
at least one external fill connection connected
into the tank that allows the tank to be filled
at a minimum rate of 1000 GPM.
3.The external fill connection should be equipped
with a valve, strainer, and a 30 degree elbow.
4. Valves that are three inches or larger must be
of the slow closing design.
5.An MWS apparatus must have at least three
large tank discharges capable of discharging 90%
of the tank volume at an average of 1000 GPM.
When Checking the left front or right saddle tanks
front side of the fire apparatus, don't
forget to inspect the:
, Daily inspection Ensure auxiliary fuel tank is
full Operate pump primer
Inspect auxiliary winterization system.
Weekly Inspection Clean intake strainers
Pre-service pump certification test An independent testing agency
are conducted by:
When using a static body of water as 10 Feet
above your water source during fire
apparatus service testing, the water 4 Feet
deep surface must not be more than___
feet above the centerline of the
pump intake and the water must
be at least_feet deep.
If the engine speed check proves the Stop the testing until the problem is corrected.
MWS apparatus is running at a
different speed than what which it
was originally rated, you need to?
A year has passed and its time Connect 20 Feet of the hard suction hose to the
conduct the annual vacuum test on pump intake connection.
your departments MWS apparatus.
You're following the procedures for
conducting the vacuum test and
you've already checked for and
removed foreign matter from the
hard suction hose. The next step
to perform while conducting
the vacuum test is to: