100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NICET 1 EXAM PRACTICE TEST QUESTIONS AND ANSWERS 100% VERIFIED

Puntuación
-
Vendido
-
Páginas
37
Grado
A+
Subido en
08-11-2024
Escrito en
2024/2025

NICET 1 EXAM PRACTICE TEST QUESTIONS AND ANSWERS 100% VERIFIED A room measures 60'ft long by 60'ft wide and has a smooth flat ceiling 10'ft high. A spot-type heat detector with a listed spacing of 30'ft was selected to be installed. According to NFPA 72, what is the minimum number of detectors required? a. 1 b. 2 c. 4 d. 6 - Answer c. 4 According to NFPA 72, line type heat detectors shall be located on the ceiling or on the sidewalks not more than _________. a. 20 inches from the ceiling b. 20 inches from the sidewall c. 30 inches from the ceiling d. 30 inches from the sidewall - Answer a. 20 inches from the ceiling A parallel circuit has a total circuit current of 2 amperes. What is the applied circuit voltage if the total resistance is 6 Ohms? a. 3 Volts b. 0.33 Volts c. 8 Volts d. 12 Volts - Answer d. 12 Volts

Mostrar más Leer menos
Institución
NICET 1
Grado
NICET 1











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NICET 1
Grado
NICET 1

Información del documento

Subido en
8 de noviembre de 2024
Número de páginas
37
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NICET 1 EXAM PRACTICE
TEST 2024-2025
QUESTIONS AND
ANSWERS 100% VERIFIED
A room measures 60'ft long by 60'ft wide and has a smooth flat ceiling 10'ft high. A spot-
type heat detector with a listed spacing of 30'ft was selected to be installed. According
to NFPA 72, what is the minimum number of detectors required?

a. 1

b. 2

c. 4

d. 6 - Answer ✔ c. 4

According to NFPA 72, line type heat detectors shall be located on the ceiling or on the
sidewalks not more than _________.

a. 20 inches from the ceiling

b. 20 inches from the sidewall

c. 30 inches from the ceiling

d. 30 inches from the sidewall - Answer ✔ a. 20 inches from the ceiling

A parallel circuit has a total circuit current of 2 amperes. What is the applied circuit
voltage if the total resistance is 6 Ohms?

a. 3 Volts

,b. 0.33 Volts

c. 8 Volts

d. 12 Volts - Answer ✔ d. 12 Volts

Stairways having _____ or more risers shall be equipped with at least one handrail.

a. 3

b. 4

c. 5

d. 6 - Answer ✔ b. 4

Battery chargers shall be tested ______.

a. Monthly

b. Quarterly

c. Semiannually

d. Annually - Answer ✔ d. Annually

When the top edge of a stair rail system also serves as a handrail, the height of the top
edge shall be more than ______ nor less than ______ from the upper surface of the
stair rail system to the surface of the tread, in line with the face of the riser at the
forward edge of the tread.

a. 37 inches/36 inches

b. 40 inches/36 inches

c. 37 inches/30 inches

d. 40 inches/ 37 inches - Answer ✔ a. 37 inches/36 inches

What is the maximum amount of 12 AWG THHN conductors that can be installed in .75
inch EMT?

a. 9

b. 16

,c. 26

d. 45 - Answer ✔ b. 16

Branch circuits shall have an allowable ampacity of ______.

a. Not less tan 125% of the non continuous load

b. Not less than 100% of the continuous load

c. Not less than 100% of the continuous load and 125% of the non continuous load

d. Not less than 100% of the non continuous load and 125% of the continuous load -
Answer ✔ d. Not less than 100% of the non continuous load and 125% of the
continuous load

Maintenance of the household fire alarm systems be conducted ________.

a. Annually

b. Semi annually

c. Monthly

d. According to the manufacturer's instructions - Answer ✔ d. According to the
manufacturer's instructions

If guards are used to protect a notification appliance such as a strobe light it shall be
_______.

a. Be listed to be used with the appliance

b. Be of metal only

c. Be used on notification appliances that are mounted no higher than 90 inches above
finished floor

d. Guards are not allowed on notification appliances. - Answer ✔ a. Be listed to be used
with the appliance

The alarm audible signal pattern used to notify building occupants of the need to
evacuate shall be the standard alarm evacuation signal consisting of a ______.

a. Two pulse Temporal Pattern

b. Three pulse Temporal Pattern

, c. Accompanying visible signal

d. Voice evacuation instructions - Answer ✔ b. Three pulse Temporal Pattern

Aerial lifts may be "field modified" for uses other than those intended by the
manufacturer provided the modification has been _______________.

a. Tested by the employer prior to its use

b. Reported to OSHA prior to its use

c. Certified in writing by the manufacturer

d. None of the above. Field modifications of aerial lifts are strictly prohibited by OSHA -
Answer ✔ c. Certified in writing by the manufacturer

In every building or structure exits shall be so arranged and maintained as to provide
free and unobstructed egress from all parts of the building or structure ______.

a. At all times when it is occupied

b. During construction only

c. That is accessible to personnel

d. None of the above - Answer ✔ a. At all times when it is occupied

All fire alarm systems shall test free of ______.

a. Dirt

b. Errors

c. Grounds

d. Power Loss - Answer ✔ c. Grounds

The secondary power supply for in building mass notifciation systems shall be capable
of operating the system for a minimum of _____ and shall be capable of operating the
system during emergency condition for ____ at maximum connected load.

a. 24 Hours/ 15 Minutes

b. 24 Hours/ 5 Minutes

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Scholarsstudyguide nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
778
Miembro desde
3 año
Número de seguidores
475
Documentos
14976
Última venta
13 horas hace
NURSING

Here you will find everything you need in nursing Assignments, EXAMS AND TESTBANKS. For students who want to see results twice as fast. I strive for my content to be of the highest quality. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.9

163 reseñas

5
87
4
21
3
25
2
6
1
24

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes