100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM QUESTIONS AND ACCURATE ASNWERS GRADED A+

Puntuación
-
Vendido
-
Páginas
25
Grado
A+
Subido en
29-08-2025
Escrito en
2025/2026

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM QUESTIONS AND ACCURATE ASNWERS GRADED A+

Institución
BACKFLOW PREVENTION ASSEMBLY TESTER
Grado
BACKFLOW PREVENTION ASSEMBLY TESTER










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
BACKFLOW PREVENTION ASSEMBLY TESTER
Grado
BACKFLOW PREVENTION ASSEMBLY TESTER

Información del documento

Subido en
29 de agosto de 2025
Número de páginas
25
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM
QUESTIONS AND ACCURATE ASNWERS GRADED A+

In |responding |to |a |backflow |incident |the |water |purveyor |should

(A) Call |the |mayor

(B) Implement |the |emergency |response |plan

(C) Install |a |vacuum |breaker

(D) Develop |a |good |excuse |- |answer-Implement |the |emergency |response |plan



A |mixture |of |air |and |gas |is |considered |hazardous |when |the |mixture |exceeds |what |percentage |of |gthe
|lower |explosive |limit



(A) 0%

(B) 3%

(C) 7%

(D) 10% |- |answer-10%



To |exert |a |pressure |of |1.0 |psi |at |base |of |a |water |column |the |column |would |have |to |be

(A) 4.34 |high

(B) 14.7 |high

(C) 27.75 |high

(D) 33.89 |high |- |answer-27.75 |high



A |DC |must |be |tested

(A) Upon |installation

(B) Every |6 |month

(C) Annually |on |a |health |hazard

(D) none |of |the |above |- |answer-Upon |installation



An |absolute |perssure |of |25 |psiaa |(at |sea |level) |is |equal |to |approximately

(A) 5 |psi

,(B) 10 |psi

(C) 20 |psi

(D) 25 |psi |- |answer-10 |psi



Dueing |a |field |test |the |air |inlet |on |PVB |must |open |at

(A) Above |2.0 |psid

(B) Below |1.0 |psid

(C) Above |1.0 |psid

(D) Below |2.0 |psid |- |answer-Above |1.0 |psid



A |differential |pressuer |gauge |is |used |to |field |test

(A) PVB's

(B) Dual |Checks

(C) AVB's

(D) All |the |above |- |answer-PVB's



Backflow |in |a |water |supply |can |be |caused |by

(A) Backpressure |only

(B) A |Barometric |Loop

(C) Backsiphonage |only

(D) Backpressure |and |Backsiphonage |- |answer-Backpressure |and |Backsiphonage



A |BPAT |tester |is |required |to |report |test |information |on |the |proper |forms |to |the

(A) Administrative |authority

(B) Manufacturer's |Rep

(C) EPA

(D) None |of |the |above |- |answer-Administrative |authority



The |relief |valve |opens |when |closing |#2 |shut |off |valve |on |a |RP |What |is |the |most |probable |cause

, (A) #1 |Shut |off |valve |is |open

(B) #2 |Shut |off |valve |is |open

(C) #1 |check |is |fouled |open

(D) Shut |off |is |leaking |- |answer-#1 |check |is |fouled |open



When |field |testing |the |#1 |Check |of |a |RP |the |differential |pressurw |shouid |be

(A) Greter |than |or |equal |to |5.0 |psid

(B) 3.0 |psid |greater |than |the |relief |valve |opening |point

(C) 1.0 |psid |in |the |directiom |of |flow

(D) Less |than |5.0 |psid |- |answer-Greter |than |or |equal |to |5.0 |psid



When |testing |a |SVB |what |is |the |firsrt |test |being |performed

(A) The |air |inlet |opening |point

(B) The |static |pressure |across |the |check |valve

(C) To |verify |the |#2shut |off |hold |tight

(D) To |check |if |the |SVB |hold |water |- |answer-The |static |pressure |across |the |check |valve



When |testing |a |PVB |the |air |inlet |opens |upon |closing |the |#1 |shut |off |valve |What |is |the |most |probable
|cause



(A) Leaking |#2 |shut |off |valve

(B) Leaking |#1 |shut |off |valve

(C) Fouied |air |inlert

(D) Fouied |check |valve |- |answer-Leaking |#2 |shut |off |valve



A |2" |AVB |when |used |on |irrigation |systemsterm-15 |shall |be |instilled

(A) 6" |above |all |downstream |piping

(B) 18" |above |all |downstream |piping

(C) 24" |above |all |downstream |piping

(D) 27 |3/4" |above |all |downstream |piping |- |answer-6" |above |all |downstream |piping
$18.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectphilip West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
165
Miembro desde
1 año
Número de seguidores
6
Documentos
17720
Última venta
4 horas hace
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4.4

23 reseñas

5
14
4
5
3
3
2
1
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes