Alabama Fire College Inspector 1/2 Already Graded A
Alabama Fire College Inspector 1/2 Already Graded A Fire protection engineers have established _____ PSI as a minimum required residual pressure when computing the available water for flow test results. 20psi The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM. 500 - 1500 gpm A fire pump serving a standpipe system should be tested ______ weekly A fire department pumper can effectively supply around ______ feet in a high rise building depending on hydrant pressure and other factors. 450 feet Class 2 standpipe is for __________ use occupational Standpipe classifications: 1. 2 3. 1. Fire Dept only 2. Occupant use only 3. Both Fire Dept and Occupant use NFPA 13D requires _______ for any sprinkler 18 GPM Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi residual pressure at the highest outlet. 500 Stored material should not be stacked closer than ____ inches to a sprinkler head 18 inches _______ system is used when it is especially important that water damage be prevented, even if the sprinkler pipes should break accidentally. Preaction Fire dampers are usually activated by _____ ______ fusible links ________ detectors are - activated by heat (expansion) and are self-resetting (automatic) Bimetallic Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and propane B Pressure tanks should be filled ______ of water with ____ psi 2/3; 75psi Fire extinguishers >40lbs should be mounted no higher than ______ feet from the floor 3 ½ _______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate and water Wet chemical _______ _______ extinguishers limitations are the clean-up Dry chemical _____ ______ agents are difficult to clean up due to water repellant Dry chemical When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers must be at least ______ feet apart 20 feet Freeboard should never be more than ___ inches 6 _________ ________ is wood chips glued together to make flat sheets Particle board The maximum size for an approved safety can is ___ gallons 5 Open burning fire should not be allowed within ______ feet of a structure 50 Approved incinerators for burning trash should be at least _____ feet from a structure 15 Fire in an approved burn container should not be within ____
Escuela, estudio y materia
- Institución
- Alabama Fire College Inspector 1/2
- Grado
- Alabama Fire College Inspector 1/2
Información del documento
- Subido en
- 19 de diciembre de 2023
- Número de páginas
- 40
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
alabama fire college inspector 12 already graded
Documento también disponible en un lote