Vista previa del contenido

TFM 12

What does PLFA stand for? - ANSPower Limited Fire Alarm

What does NPLFA stand for? - ANSNon-Power Limited Fire Alarm

What material must NPLFA circuit conductors be made from? - ANSSolid or stranded copper

What is a single station detector? - ANSBattery powered smoke detectors that do not
communicate off premises.

What is a multiple station detector? - ANSMains powered smoke detectors with battery backup
that are linked together, so that if one unit initiates, alarms in all detectors will sound. They do
not communicate off premises.

How frequently must household single and multiple station detectors be inspected and tested? -
ANSIn accordance with the manufacturers recommendations, at least monthly

How frequently must household fire alarm systems be inspected and tested? - ANSAt least
every 3 years, by a qualified service technician.

What does 'restorable' mean? - ANSThe detector can be 'restored' or 'reused' after it has
initiated an alarm.

What size conductors are permitted? - ANSSize 18AWG and 16AWG

What is used to protect transformers or other devices supplied from power-supply conductors? -
ANSAn overcurrent device not rated over 20 Amperes.

When located within 7ft of the floor, how shall cables be fastened? - ANSCables shall be
fastened in an approved manner at intervals of not more than 18 inches.

Single conductors shall not be smaller than __________ AWG - ANS18

Conductors of 26AWG shall only be permitted in which circumstances? - ANSWhere spliced
with a connector listed as suitable for 26 to 24 AWG

What is a Plenum cable? - ANSCable that can be installed in ducts and other spaces used for
environmental air.

What is Riser cable? - ANSCable to be used in vertical wire runs in shafts or between floors.

, What is General Purpose cable? - ANSCable for general purpose fire alarm use

What 'type' shall plenum cable be? What substitutions are allowed? - ANSFPLP

What 'type' shall riser wire be? What substitutions are permitted? - ANSFPLR

What 'type' shall general purpose wire be? What substitutions are permitted? - ANSFPL

What is the maximum voltage permitted through multi-conductor NPLFA cables? - ANS150 volts

What is the voltage rating of PLFA cables? - ANSNot less than 300 volts

Shall the voltage be marked on PLFA cables? - ANSNO

What is a 'Rate Compensation Detector'? - ANSA device that responds when the temperature
reaches a pre-determined level.

What is a 'Rate of Rise Detector'? - ANSA device that responds when the temperature rises at a
rate exceeding a pre-determined value

Which sensor is best at detecting 'invisible' smoke particles? - ANSIonization

Which sensor is best at detecting thick, 'visible' smoke particles? - ANSPhotoelectric

What is a 'Spot Type Detector'? - ANSA device in which the detecting element is concentrated
at a particular location.

What is a 'Digital DACR? - ANSDigital alarm communicator Receiver

Name a DACR - ANSImpassa

What is an Alarm Signal? - ANSA signal indicating an emergency that requires IMMEDIATE
action

Does an exterior horn for a sprinkler system need to be supervised? - ANSYES

Does a fire hood sprinkler system in a kitchen need to be monitored by the fire alarm system? -
ANSYES

What is 'Photoelectric Light-Scattering Smoke Detection'? - ANSA detector that uses a light
source and a photosensitive sensor, arranged so that light will only fall on the sensor when
smoke particles are present. The particles reflect and retract light towards the sensor, tripping
the alarm.
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ashley96 Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
590
Miembro desde
2 año
Número de seguidores
198
Documentos
5001
Última venta
6 días hace

In my page you will find all latest Exams , with Questions and Answers, package deals, etc. I upload quality. Instant delivery. You will get solutions to all subjects in both assignments and major exams. Contact me for any assistance. Good Luck!!!

4.0

156 reseñas

5
88
4
21
3
25
2
6
1
16

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes