• Falsches Dokument? Kostenlos tauschen
  • Geschrieben von Student*innen, die bestanden haben
  • Sofort verfügbar nach Zahlung
  • Online lesen oder als PDF
Verkaufen
Wo studierst du
Deine Sprache
Document preview thumbnail
Vorschau 3 aus 24 Seiten
Prüfung

AHA PALS Final Exam Study Guide - A+ Rated Study Resource

Document preview thumbnail
Vorschau 3 aus 24 Seiten

AHA PALS Final Exam Study Guide - A+ Rated Study Resource Capillary refill - answer - Capillary refill time is the time it takes for blood to return to tissue blanched by pressure. It increases as skin perfusion decreases. Note that normal capillary refill time is 2 seconds or less, and a prolonged capillary refill time may indicate low cardiac output Evaluate capillary refill in a neutral thermal environment (ie, room temperature) by - answer - • Lifting the extremity slightly above the level of the heart • Pressing on the skin • Rapidly releasing the pressure BGL in pediatrics - answer - Hypoglycemia refers to blood glucose 45 mg/dL or less in the newly born and 60 mg/dL or less in a child. It may result in brain injury if not recognized and effectively treated. Base treatment decisions on patient symptoms, and potentially include oral glucose. Monitor the blood glucose concentration of any seriously ill infant or child. A low blood glucose concentration may cause altered level of consciousness or even brain injury if it is not quickly identified and adequately treated. Measure the blood glucose concentration with a point-of-care glucose test. Important factors associated with increased work of breathing: - answer - • Increased airway resistance (upper and lower) • Decreased lung compliance • Use of accessory muscles of respiration • Disordered central nervous system control of breathing Airway resistance - answer - • Airway resistance, or the impedance to airflow within the airways, is primarily increased by reducing the size of the conducting airways, either by airway constriction or inflammation. Turbulent airflow also causes increased airway resistance. Airflow may become turbulent when the flow rate increases, even if the airway size remains unchanged. When airway resistance increases, work of breathing increases in an attempt to maintain airflow despite the increase in airway resistance. • Larger airways provide lower resistance to airflow than smaller. Airway resistance decreases as lung volume increases (inflation) because airway dilation accompanies lung inflation. • Conditions such as edema, bronchoconstriction, secretions, mucus, or a mediastinal mass impinging on large or small airways can decrease airway size, thereby increasing airway resistance. • Resistance in the upper airway, particularly in the nasal or nasopharyngeal passages, can represent a significant portion of tot Lung compliance - answer - • Compliance refers to the distensibility of the lung, chest wall, or both. Specifically, lung compliance is defined as the change in lung volume produced by a change in driving pressure across the lung. When lung compliance is high, the lungs easily inflate, a large change in volume produced by a slight change in driving pressure. • The lungs are stiffer in a child with low lung compliance, so it takes more effort to inflate them. To create a significant pressure gradient to produce air flow into the stiff lung, the diaphragm contracts more forcefully, increasing intrathoracic volume and reducing intrathoracic pressure. Poorly compliant lungs will also lead to increased work of breathing. During mechanical ventilation, increased positive airway pressure is needed to achieve adequate ventilation when lung compliance decreases. Decreased lung compliance - answer - • The chest wall in infants and young children is compliant. Therefore, relatively small pressure changes can move the chest wall. During normal breathing, diaphragm contraction in infants pulls the lower ribs slightly inward but does not cause significant chest retraction. However, forcefully contracting the diaphragm results in a large drop in pressure within the chest, pulling the chest inward (ie, retracting it) during inspiration. • When lung compliance is reduced, maximum inspiratory effort may not produce adequate tidal volume because marked retractions of the chest wall limit lung expansion during inspiration. Breathing is controlled by co


Dokument Information

Hochgeladen auf
5. november 2026
Anzahl der Seiten
24
geschrieben in
2026/2027
Typ
Prüfung
Enthält
Fragen & antworten
12,22 €

Falsches Dokument? Kostenlos tauschen Innerhalb von 14 Tagen nach dem Kauf und vor dem Herunterladen kannst du ein anderes Dokument wählen. Du kannst den Betrag einfach neu ausgeben.
Geschrieben von Student*innen, die bestanden haben
Sofort verfügbar nach Zahlung
Online lesen oder als PDF

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
SARAHnkalu
4,6
(7)
Verkauft
50
Anhänger
0
Sachen
9092
Zuletzt verkauft
2 Jahren vor



Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Arbeitest du an deiner Quellenangabe?

Erstelle korrekte Quellenangaben in APA, MLA und Harvard mit unserem kostenlosen Zitiergenerator.

Arbeitest du an deiner Quellenangabe?

Häufig gestellte Fragen

Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.