• Falsches Dokument? Kostenlos tauschen
  • Geschrieben von Student*innen, die bestanden haben
  • Sofort verfügbar nach Zahlung
  • Online lesen oder als PDF
Verkaufen
Wo studierst du
Deine Sprache
Document preview thumbnail
Vorschau 3 aus 24 Seiten
Prüfung

CBSPD Exam Practice Question Set - Practice-Ready Answer Guide

Document preview thumbnail
Vorschau 3 aus 24 Seiten

CBSPD Exam Practice Question Set - Practice-Ready Answer Guide Superheating can occur - answer - If the steam pressure is too low for the set temperature Wet packs - answer - Wet steam can cause 68-73 degrees - answer - AAMI recommends that the temperature in the sterilization area be: 30%-60% - answer - AAMI recommends that the humidity is the sterilization area be 10 - answer - The recommended ventilation in the sterilization are is—— air exchanges per hour under positive pressure 75-85/10/negative - answer - AAMI recommends that the temperature in the sterilizer access area be —- with — air exchanges per hour and under — pressure Decon, the sterilizer access area, EVS closet - answer - The only 3 areas in SPD that should have negative pressure are: sterility - answer - — is the absence of all forms of microbial life, including bacterial spores One in a million; 10(-6) - answer - An item is considered sterile if there is less than —— chance that a viable microorganism has survived the sterilization process. This is reflected numerically as —- Sterility Assurance Level - answer - SAL= Steam - answer - — kills microorganisms by denature great the protein steam sterilization - answer - — is the most common form of sterilization for items that are heat- and moisture-tolerant saturated steam under pressure, time, and temperature - answer - Three parameters of steam sterilization cycles are Dynamic-air-removal cycles - answer - — are used in prevacuum sterilized and in steam-flush pressure-pulse (SFPP) Prevacuum sterilizers - answer - — remove air by drawing series of vacuums with an injection of steam between each vacuum pull. Bowie-Dick test - answer - Performed daily to detect air leaks or inadequate air removal from prevacuum sterilzers Gravity-displacement cycles - answer - Incoming steam displaces residual air through the drain at the bottom of the sterilizer chamber: Gravity-displacement - answer - Because there is no mechanical air removal in a —, a Bowie-Dick test is not required for — or sterilizers Boiler - answer - In most healthcare facilities, steam is generated inside of a: 60-80psig - answer - The required pressure of steam as it enters the jacket is usually: 28-30 lbs of pressure - answer - For a sterilizer operating at 270 degrees, the sterilizer gauge will show: An insulating jacket - answer - Provides heat inside the chamber to prevent condensation from forming on the chamber walls: Heat-sensing thermometer - answer - The sterilizers - - - is locates in the drain line The drain line - answer - The coldest part of sterilizer is Bottom rack, drain line - answer - All PCDs should be placed on the —, directly over the — On the bottom rack above the drain line - answer - The Bowie-Dick test pack is placed Conditioning, sterilization/exposure/"holding, Exhaust, Drying - answer - The phases of steam sterilization cycles are: Conditioning phase - answer - During this phase, air is removed from the sterilization chamber and steam is injected Sterilization/exposure/holding - answer - In this phase, the exposure temperature is maintained for the prescribed amount of time. Exhausted, Exhaust phase - answer - After the exposure phase, steam is — from the sterilizer through the chamber drain line is this phase: Drying phase - answer - After the steam has been exhausted, the sterilizer goes into the - of the cycle which typically lasts about 30 minutes • 4 minutes @ 270 and 28-30 psi • 3 minutes @ 275 and 38-30 psi - answer - The cycle for wrapped items using Dynamic-air-removal steam is: • 30 minutes @ 350 and 15 psi • 15-20 minutes @ 270 and 27 psi • 10 minutes @ 275 and 30 psi - answer - The cycle for wrapped items using Gravity-displacement steam: BI PCD - answer - To verify that the cycle met the requirements for sterilization, a — should be included in the load (whether or not the load contains implantable devices) Immediate-Use steam sterilization (IUSS) - answer - —- is usually perfor


Dokument Information

Hochgeladen auf
31. oktober 2026
Anzahl der Seiten
24
geschrieben in
2026/2027
Typ
Prüfung
Enthält
Fragen & antworten
13,01 €

Falsches Dokument? Kostenlos tauschen Innerhalb von 14 Tagen nach dem Kauf und vor dem Herunterladen kannst du ein anderes Dokument wählen. Du kannst den Betrag einfach neu ausgeben.
Geschrieben von Student*innen, die bestanden haben
Sofort verfügbar nach Zahlung
Online lesen oder als PDF

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
aldrisraand
3,0
(1)
Verkauft
11
Anhänger
0
Sachen
5848
Zuletzt verkauft
1 Jahren vor



Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Arbeitest du an deiner Quellenangabe?

Erstelle korrekte Quellenangaben in APA, MLA und Harvard mit unserem kostenlosen Zitiergenerator.

Arbeitest du an deiner Quellenangabe?

Häufig gestellte Fragen

Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.