Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Surgical Technology Certification

Beoordeling
-
Verkocht
-
Pagina's
58
Cijfer
A+
Geüpload op
10-11-2025
Geschreven in
2025/2026

Surgical Technology Certification

Instelling
Surgical Tech
Vak
Surgical tech

Voorbeeld van de inhoud

Surgical Technology Certification
2025/2026 EXAM ACTUAL EXAM
QUESTIONS AND WELL ELABORATED
ANSWERS WITH (100% VERIFIED
SOLUTIONS) LATEST
UPDATES | ALREADY GRADED A+


Which of the following is the correct temperature for pre-vacuum
sterilization? a. 212*F
b. 170*F
c. 300*F
d. 270*F - ANSWER>>ANSWER: D


Which of the following tests is specifically meant to test and monitor the
efficiency of the high - vacuum steam sterilizer? a. biological indicator
test
b. DART test
c. chemical indicator test
d. EtO test - ANSWER>>ANSWER:
B DART test = Bowie Dick test

,The surgical team must verify each package is properly labeled with a.
date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date
d. indicator and expiration date - ANSWER>>ANSWER: B


How many times a day should a DART test be preformed? a.
with every load
b. every shift change
c. once every 24 hours
d. weekly - ANSWER>>ANSWER: C


How often must a biological control test be run? a.
every day
b. every cycle
c. once a week
d. once a month -
ANSWER>>ANSWER: A [pg. 163]


The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments -
ANSWER>>ANSWER: B

,lot control numbers should be placed on each package sterilized and on
the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart - ANSWER>>ANSWER: B


How long is a 3M Attest 1292 steam biological indicator incubated before
the reading is recorded? a. 12 hours
b. 36 hours
c. 24 hours
d. 48 hours - ANSWER>>ANSWER:
C 12 hours - rapid ; 24 hours - not
rapid


During a vascular procedure a vessel is ligated. The surgeon states that
she will repair the vessel after bleeding is controlled. Which needle type
would she most likely require to complete this task? a. control release
needle
b. French eyed needle
c. tapered needle
d. cutting needle - ANSWER>>ANSWER: C

When steam sterilizing biological indicators, how long are they incubated
before the reading is recorded? a. 48 hours
b. 24 hours
c. 12 hours
d. 72 hours - ANSWER>>ANSWER: B

, An OB-GYN surgeon has posted a laparoscopic partial hysterectomy and
has informed the surgical team that the ovaries are remaining. However,
the fallopian tubes will require ligation involoving the tubes being clipped
and cauterized. Which of the following instruments should the surgical
technologist open
a. a Flishie and hemoclip applier
b. a Flishie and Kleppinger
c. a Kleppinger and harmonic scalpel
d. a harmonic scalpel and hemoclip applier - ANSWER>>ANSWER: D


Which of the following instruments can be decontaminated in the
washersterilizer?
a. colonoscope
b. power drill
c. laser coated instrument set
d. phaco instrument set - ANSWER>>ANSWER: C


The patient has undergone cardiac bypass surgery. Protamine has been
administered and the surgeon is preparing to close the sternotomy.

Bleeding is a postoperative concern. Which of the following systems should
the surgical technologist anticipate the surgeon will use? a. Hemovac
b. Jackson Pratt
c. Pleur-Evac
d. Penrose - ANSWER>>ANSWER: C

Geschreven voor

Instelling
Surgical tech
Vak
Surgical tech

Documentinformatie

Geüpload op
10 november 2025
Aantal pagina's
58
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€11,59
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AndrewBenson Johns Hopkins University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
23
Lid sinds
1 jaar
Aantal volgers
0
Documenten
1999
Laatst verkocht
1 maand geleden

3,0

2 beoordelingen

5
1
4
0
3
0
2
0
1
1

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen