Production 2025 Questions and Answers


Which of the following reduces the scatter radiation reaching the detectors? - --

CORRECT ANSWER--both a and c

(Pre-detector collimation and post-patient collimation are synonymous. Both terms

describe a device designed to remove scatter radiation before it reaches the

detector.)

Which of the following is the primary interaction between x-ray photons and tissue

during computed tomography? - --CORRECT ANSWER--Compton effect

(Owing to the high-energy beam used in CT, the Compton effect is the

predominant interaction between x-ray and matter. CT scanners use between 120

and 140 kVp, yielding x-ray energies with averages between 70 and 80 keV.)

The process by which electrons are produced at the cathode of a CT x-ray tube is

known as: - --CORRECT ANSWER--thermionic emission

(When the cathode of an x-ray tube is heated, electrons are released through the

process of thermionic emission. It is these electrons that are then accelerated

toward the anode for x-ray production.)


....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 1

,The assignment of different generations to CT scanners is based on the

configuration of the: - --CORRECT ANSWER--tube and detectors

(CT scanners are often placed into one of several different "generations." The

differences in generations are based on the relationship of the tube and detectors

and the position of each during data acquisition.)

When one is using a third-generation CT scanner, it is important that reference

detectors positioned at the peripheral portions of the detector array be exposed to:

- --CORRECT ANSWER--unattenuated radiation

(Reference detectors are used to measure incident radiation intensity. This

information is used by the computer during the calculation of the linear

attenuation coefficient. If the patient is placed incorrectly within the gantry, the

reference detectors may be partially blocked, causing an out-of-field artifact.)

In 1979, the scientists __________ and __________ shared the Nobel Prize for

their research in computed tomography. - --CORRECT ANSWER--Hounsfield

and Cormack

(Dr. Godfrey Hounsfield and Dr. Allan Cormack shared the Nobel Prize for their

work on the development of computed tomography in 1979.)

The type of compensating filter used at the x-ray tube of a CT scanner is called a: -

--CORRECT ANSWER--bow-tie filter




....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 2

,(The bow-tie filter used at the x-ray tube of a CT scanner absorbs a larger amount

of radiation at the periphery of the patient, where the part thickness is reduced.

The center of the patient is placed at the center of the filter, where the largest

amount of radiation is allowed to pass through. The use of this type of filter

attempts to compensate for the differences in thickness of the often oval-shaped

patient.)

The interaction between x-ray and matter that is responsible for the production of

the scatter radiation absorbed by the patient and detectors is: - --CORRECT

ANSWER--Compton effect

(In the Compton interaction, an x-ray photon ejects an outer-shell electron of an

atom. The photon loses some of its energy in the collision and then continues on

in a different, scattered direction. This interaction is the major source of the scatter

radiation involved in the formation of the CT image.)

The types of detectors used in computed tomography are:

1. Gas ionization

2. Stimulable phosphor

3. Scintillation - --CORRECT ANSWER--1 and 3 only

(The types of detectors used in computed tomography are scintillation and gas

ionization detectors. Both operate by measuring the amount of transmitted

radiation passed through the patient and transmitting this information to the


....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 3

, computer for image reconstruction. Newer MDCT systems utilize solid-state

scintillation detectors exclusively.)

Which of the following is used in gas ionization CT detectors? - --CORRECT

ANSWER--xenon

(Gases with high atomic numbers, such as xenon, are used in ionization-type CT

detector systems. The high atomic number of the xenon gas (Z = 54) increases the

incidence of interaction with x-ray photons, thus improving the efficiency of the

detector.)

Which of the following statements concerning the translate-rotate mode of CT

data acquisition is/are correct?1. 360-degree circular detector arrays are used.2.

Data are collected only during translation.3. Was used in first- and second-

generation CT scanners. - --CORRECT ANSWER--2 and 3 only

(The first- and second-generation CT scanners used a translate-rotate method of

data acquisition. The x-ray tube and detector(s) translated across the patient's head,

recording transmission measurements. The entire system then rotated 1 degree.

This process of translation-rotation then repeated itself for a total of 180 degrees.

First- and second-generation CT scanners used anywhere from 2 to 30 detectors.)

Which of the following terms accurately describes the type of x-ray beam used in a

third-generation CT scanner? - --CORRECT ANSWER--Fan beam




....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 4

Documentinformatie

Geüpload op
1 augustus 2025
Aantal pagina's
31
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
€11,94

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
KatelynWhitman
3,6
(260)
Verkocht
1269
Volgers
485
Items
43877
Laatst verkocht
10 uur geleden


Echte notities, van echte studenten
Elk document op Stuvia is geschreven door een medestudent die hetzelfde vak deed. Zo leer je van iemand die het al heeft gehaald.



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen