• Verkeerd document? Gratis ruilen
  • Geschreven door studenten die geslaagd zijn
  • Direct beschikbaar na je betaling
  • Online lezen of als PDF
Verkopen
Kies je studieland
Kies je taal
Document preview thumbnail
Voorbeeld 4 van de 60 pagina's
Tentamen (uitwerkingen)

Image Production - Mosby's Exam Review UPDATED ACTUAL Exam Questions and CORRECT Answers

Document preview thumbnail
Voorbeeld 4 van de 60 pagina's

Image Production - Mosby's Exam Review UPDATED ACTUAL Exam Questions and CORRECT Answers Which of the following reduces the scatter radiation reaching the detectors? A. Post-patient collimation B. Pre-patient collimation C. Pre-detector collimation D. Both a and c - CORRECT ANSWER - D. Both a and c Pre-detector collimation and post-patient collimation are synonymous. Both terms describe a device designed to remove scatter radiation before it reaches the detector.

Voorbeeld van de inhoud

Image Production - Mosby's Exam Review
UPDATED ACTUAL Exam Questions and
CORRECT Answers
Which of the following reduces the scatter radiation reaching the detectors?


A. Post-patient collimation
B. Pre-patient collimation
C. Pre-detector collimation

D. Both a and c - CORRECT ANSWER - D. Both a and c


Pre-detector collimation and post-patient collimation are synonymous. Both terms describe a
device designed to remove scatter radiation before it reaches the detector.


Which of the following is the primary interaction between x-ray photons and tissue during
computed tomography?


A.Bremsstrahlung
B.Characteristic
C. Compton effect

D. Coherent scatter - CORRECT ANSWER - C. Compton effect


Owing to the high-energy beam used in CT, the Compton effect is the predominant interaction
between x-ray and matter. CT scanners use between 120 and 140 kVp, yielding x-ray energies
with averages between 70 and 80 keV.


The process by which electrons are produced at the cathode of a CT x-ray tube is known as:


A.rectification.

,B. anode heel effect.
C. thermionic emission.

D. isotropic emission. - CORRECT ANSWER - C. thermionic emission.


When the cathode of an x-ray tube is heated, electrons are released through the process of
thermionic emission. It is these electrons that are then accelerated toward the anode for x-ray
production.


The assignment of different generations to CT scanners is based on the configuration of the:


A. patient and gantry.
B. tube and detectors.
C. anode and cathode.

D. tube and collimators. - CORRECT ANSWER - B. tube and detectors.


CT scanners are often placed into one of several different "generations." The differences in
generations are based on the relationship of the tube and detectors and the position of each
during data acquisition.


When one is using a third-generation CT scanner, it is important that reference detectors
positioned at the peripheral portions of the detector array be exposed to:


A. homogeneous radiation.
B. unattenuated radiation.
C. monochromatic radiation.

D. remnant radiation. - CORRECT ANSWER - B. unattenuated radiation


Reference detectors are used to measure incident radiation intensity. This information is used by
the computer during the calculation of the linear attenuation coefficient. If the patient is placed
incorrectly within the gantry, the reference detectors may be partially blocked, causing an out-of-
field artifact.

,In 1979, the scientists __________ and __________ shared the Nobel Prize for their research in
computed tomography.


A. Watson and Crick
B. Olendorf and Hounsfield
C. Hounsfield and Cormack

D. Hounsfield and Ambrose - CORRECT ANSWER - C. Hounsfield and Cormack


Dr. Godfrey Hounsfield and Dr. Allan Cormack shared the Nobel Prize for their work on the
development of computed tomography in 1979.


The type of compensating filter used at the x-ray tube of a CT scanner is called a:


A.kernel.
B. water bath.
C. bow-tie filter.

D. wedge filter. - CORRECT ANSWER - C. bow-tie filter.


The bow-tie filter used at the x-ray tube of a CT scanner absorbs a larger amount of radiation at
the periphery of the patient, where the part thickness is reduced. The center of the patient is
placed at the center of the filter, where the largest amount of radiation is allowed to pass through.
The use of this type of filter attempts to compensate for the differences in thickness of the often
oval-shaped patient.


The interaction between x-ray and matter that is responsible for the production of the scatter
radiation absorbed by the patient and detectors is:


A. Compton effect.
B.bremsstrahlung.

, C.photoelectric.

D.characteristic. - CORRECT ANSWER - A. Compton effect.


In the Compton interaction, an x-ray photon ejects an outer-shell electron of an atom. The photon
loses some of its energy in the collision and then continues on in a different, scattered direction.
This interaction is the major source of the scatter radiation involved in the formation of the CT
image.


The types of detectors used in computed tomography are:
1. Gas ionization
2. Stimulable phosphor
3. Scintillation


A. 1 only.
B. 3 only.
C. 1 and 3 only.

D. 2 and 3 only. - CORRECT ANSWER - C. 1 and 3 only.


The types of detectors used in computed tomography are scintillation and gas ionization
detectors. Both operate by measuring the amount of transmitted radiation passed through the
patient and transmitting this information to the computer for image reconstruction. Newer
MDCT systems utilize solid-state scintillation detectors exclusively.


Which of the following is used in gas ionization CT detectors?


A. Neon
B.Xenon
C.Helium

D.Nitrogen - CORRECT ANSWER - B.Xenon

Documentinformatie

Geüpload op
26 juli 2025
Aantal pagina's
60
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
€13,78

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STANFORDGRADESS
4,0
(242)
Verkocht
1693
Volgers
109
Items
122074
Laatst verkocht
4 uur geleden


Echte notities, van echte studenten
Elk document op Stuvia is geschreven door een medestudent die hetzelfde vak deed. Zo leer je van iemand die het al heeft gehaald.



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen