HVAC, EPA 608 Certification Study Guide Comprehensive Questions and Answers 100% A+ Graded Are there drop-in replacements for R-12 systems? Why or why not? - CORRECT ANSWER-No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. What type of oil is used in R-134a and what oils will it mix with? - CORRECT ANSWER-Ester based oils and they do not mix with other oils What type of lubricant is used with HCFCs? - CORRECT ANSWER-Alkylbenzene lubricant What is difference b/w ternary blend a azeotropic blend? - CORRECT ANSWER-Ternary blends are three-part mixtures whereas azeotropic blends are blends of two or more compounds that act like a single compound. What is the trait of a hygroscopic lubricant? - CORRECT ANSWER-It absorbs (takes on) moisture What is temperature glide and what type of blend won't have it? - CORRECT ANSWER-Temp. blend is the difference between the dew point and the bubble point Dew Point - CORRECT ANSWER-Occurs when saturation temp in evaporator causes refrigerant to change from liquid to vapor Bubble Point - CORRECT ANSWER-Occurs when saturation temp in condenser changes refrigerant from vapor to liquid Will the gases in a ternary blend leak at the same rate? Why or why not? - CORRECT ANSWER-No because different refrigerants in blend have different vapor pressures, causing them to leak at uneven rates Refrigeration Process - CORRECT ANSWER-transfer of heat from one place to another Evaporator - CORRECT ANSWER-Absorbs heat into system from space to be cooled. Absorption of heat causes refrigerant to boil. Upon leaving, refrigerant changed to low pressure, low temperature vapor Compressor - CORRECT ANSWER-Takes low pressure, low temp vapor and changes it to a high-temp, high-pressure, superheated vapor and delivers it to the condenser Condenser - CORRECT ANSWER-Rejects heat from system and changes refrigerant from high-temp, high-pressure vapor into high-pressure, high-temp liquid Metering Device - CORRECT ANSWER-reduces pressure of refrigerant and changes the high-pressure, high-temp liquid into low pressure, low temp liquid. Compound Gauge - CORRECT ANSWER-Typically blue and measures low pressure (psig) and vacuum (inHg). High Pressure Gauge - CORRECT ANSWER-Red and measures high side (discharge) pressure. 0 to 500 psi What does a compressor compress? - CORRECT ANSWER-Vapor
Geschreven voor
- Instelling
- EPA 608
- Vak
- EPA 608
Documentinformatie
- Geüpload op
- 20 mei 2024
- Aantal pagina's
- 9
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
hvac epa 608 certification study guide comprehen
Ook beschikbaar in voordeelbundel