IBC COMPLETE QUESTIONS AND
ANSWERS GRADED A+
◉ A group I-1 occupancy shall include a building or part thereof
for more than ____ persons who reside on a 24-hour basis in a
supervised environment and receive custodial care.
Answer: 16
◉ Semiconductor fabrication facilities and comparable research
and development areas in which hazardous production materials
(HPM) are used are classified as Group ____
Answer: H-5
◉ Buildings and structures that contain materials that are health
hazards shall be classified as Group ____ where the amounts
exceed the maximum allowable quantities.
Answer: H-4
◉ Buildings or structures that contain materials that readily
support combustion or present a physical hazard shall be
classified as Group ____
Answer: H-3
,◉ Buildings and structures that contain materials that present a
deflagration hazard or a hazard from accelerated burning shall be
classified as Group ____
Answer: H-2
◉ A Group I-1 assisted living facility where the care recipients
may require limited verbal or physical assistance during egress
activities is considered condition ____
Answer: 2
◉ Hospitals, nursing homes and similar medical care facilities
shall be classified as Group _____ occupancies.
Answer: I-2
◉ Nursing homes are considered to be Group I-2, Condition ____
occupancies.
Answer: 1
◉ A Group I-3 occupancy shall include buildings that are
inhabited by more than ____ persons who are under restraint or
security.
Answer: five (5)
◉ Rooms and spaces within places of religious worship providing
custodial care during religious functions shall be classified as ____ ,
____ , ____ , ____ , ____ .
,Answer: part of the primary occupancy
◉ Motor fuel-dispensing facilities and department stores are
examples of Group ____ occupancies.
Answer: M
◉ Owner occupied lodging houses with ____ or fewer guest rooms
and ____ or fewer total occupants are permitted to be constructed
in accordance with the International Residential Code.
Answer: five (5), ten (10)
◉ Transient hotels and motels are examples of Group ____
occupancies.
Answer: R-1
◉ A room used for storage purposes that is ____ to another
occupancy shall be classified as part of that occupancy.
Answer: accessory
◉ Apartment houses are considered Group ____ occupancies.
Answer: R-2
◉ Facilities for more than five but not more than 16 occupants,
excluding staff, who reside on a 24-hour basis in a residential
, environment and receive custodial care are Group ____
occupancies.
Answer: R-4
◉ Nontransient congregate living facilities with ____ or fewer
occupants are classified as Group R-3 occupancies.
Answer: 16
◉ Buildings used for storage that are not classified as a hazardous
occupancy are classified as Group ____.
Answer: S
◉ Barns, private garages, tanks, and towers are all examples of
Group _____ occupances.
Answer: U
◉ In a covered mall building, a fire-resistance-rated separation is
not required between _________ and the mall.
Answer: tenant spaces
◉ In determining required means of egress of the mall in a
covered mall building, occupant load factor (OLF) is not required
to be less than ____ and shall not exceed ____
Answer: 30, 50.
ANSWERS GRADED A+
◉ A group I-1 occupancy shall include a building or part thereof
for more than ____ persons who reside on a 24-hour basis in a
supervised environment and receive custodial care.
Answer: 16
◉ Semiconductor fabrication facilities and comparable research
and development areas in which hazardous production materials
(HPM) are used are classified as Group ____
Answer: H-5
◉ Buildings and structures that contain materials that are health
hazards shall be classified as Group ____ where the amounts
exceed the maximum allowable quantities.
Answer: H-4
◉ Buildings or structures that contain materials that readily
support combustion or present a physical hazard shall be
classified as Group ____
Answer: H-3
,◉ Buildings and structures that contain materials that present a
deflagration hazard or a hazard from accelerated burning shall be
classified as Group ____
Answer: H-2
◉ A Group I-1 assisted living facility where the care recipients
may require limited verbal or physical assistance during egress
activities is considered condition ____
Answer: 2
◉ Hospitals, nursing homes and similar medical care facilities
shall be classified as Group _____ occupancies.
Answer: I-2
◉ Nursing homes are considered to be Group I-2, Condition ____
occupancies.
Answer: 1
◉ A Group I-3 occupancy shall include buildings that are
inhabited by more than ____ persons who are under restraint or
security.
Answer: five (5)
◉ Rooms and spaces within places of religious worship providing
custodial care during religious functions shall be classified as ____ ,
____ , ____ , ____ , ____ .
,Answer: part of the primary occupancy
◉ Motor fuel-dispensing facilities and department stores are
examples of Group ____ occupancies.
Answer: M
◉ Owner occupied lodging houses with ____ or fewer guest rooms
and ____ or fewer total occupants are permitted to be constructed
in accordance with the International Residential Code.
Answer: five (5), ten (10)
◉ Transient hotels and motels are examples of Group ____
occupancies.
Answer: R-1
◉ A room used for storage purposes that is ____ to another
occupancy shall be classified as part of that occupancy.
Answer: accessory
◉ Apartment houses are considered Group ____ occupancies.
Answer: R-2
◉ Facilities for more than five but not more than 16 occupants,
excluding staff, who reside on a 24-hour basis in a residential
, environment and receive custodial care are Group ____
occupancies.
Answer: R-4
◉ Nontransient congregate living facilities with ____ or fewer
occupants are classified as Group R-3 occupancies.
Answer: 16
◉ Buildings used for storage that are not classified as a hazardous
occupancy are classified as Group ____.
Answer: S
◉ Barns, private garages, tanks, and towers are all examples of
Group _____ occupances.
Answer: U
◉ In a covered mall building, a fire-resistance-rated separation is
not required between _________ and the mall.
Answer: tenant spaces
◉ In determining required means of egress of the mall in a
covered mall building, occupant load factor (OLF) is not required
to be less than ____ and shall not exceed ____
Answer: 30, 50.