If the cover for an underground pull box used for circuits over 600v
is not locked, bolted, or screwed into place, then it must weigh
equal to— Answer: 100 pounds

The maximum total voltage droop on a branch circuit is— Answer:
3%

the floors of vaults in contact with the earth shall be of concrete
that is not less then— Answer: 6 inches thick

according to the NEC bare live parts are guarded from the public in
the following methods except— Answer: protected by fireproof
curtain

equipment associated with the electrical installation can be located
above or below other electrical equipment within their working
space when the associated equipment dose not extend more then—
Answer: 6inches

when the code uses the words it means the identified actions are
allowed but not required, and may be optional— Answer: shall be
permitted


© 2025 All rights reserved

,2
a 120 volt 15-20 amp receptacle shall be located with in of air
conditioning and refrigeration, heating systems— Answer: 25 feet

in the NEC the words . indicate a mandatory requirement— Answer:
shall not or shall be permitted

as per New York city code in addition to the number of circuits
required in a dwelling unit an individual branch circuit shall be
provided for each receptacle— Answer: air conditioner

the dimensions of working space for access to live parts operating
at 300 volts normally to ground where exposed to live parts on
both sides of the workspace is— Answer: 4 feet

when leads are supplied with lampholders with lamp holders the
conductor attached to the screw shell shall have a finish— Answer:
white or gray

how many receptacles are required within the perimeter of the
balcony, deck or porch with the useable . area of 20 sq ft— Answer:
one

where conductors of different systems are installed in the same
raceway, one system shall have a neutral having an outer covering
of white or gray and each other system having a neutral shall have
another covering of— Answer: white with a color stripe other than
green


© 2025 All rights reserved

, 3
outlets may be installed in a dwelling unit for specific appliance
such as laundry equipment. the maximum distance between this
outlet and appliance— Answer: 6 feet

on a 4 wire delta system where the midpoint of one phase winding
is grounded only the conductor shall have a higher phase voltage to
ground. the conductor shall be marked— Answer: orange

where this code specifies that one equipment shall be ''in sight
from'' ''within sight from'' or ''within sight of'',and so forth, another
equipment, the specified equipment is to be visible and not more
than distance from the other— Answer: 50 feet

a door used by personnel to exit the work space that is less than 25
feet from the work space shall— Answer: swing outward with
simple ease

the authority having jurisdiction has the responsibility— Answer: for
making interpretations of rules

where rear access is required to work on de-energized parts on the
back of enclosed equipment a minimum working space of
horizontally shall be provided— Answer: 36 inches

for equipment rated at 1200 amps or more and over 6 feet wide
that contains overcurrent devices, switching devices, or control
devices. there shall be one entrance to and egress from the required


© 2025 All rights reserved

Documentinformatie

Geüpload op
17 januari 2026
Aantal pagina's
23
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden
€12,40

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Passit
3,5
(23)
Verkocht
128
Volgers
6
Items
14482
Laatst verkocht
2 weken geleden

Echte notities, van echte studenten
Elk document op Stuvia is geschreven door een medestudent die hetzelfde vak deed. Zo leer je van iemand die het al heeft gehaald.



Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen