S-13 practice || Guaranteed Pass!!!
Standpipe systems primarily use ________________ as an extinguishing agent. correct answers Water provided from a Gravity Tank Water provided from a Pressure Tank Water provided from a Fire Pump Fire protection systems must be extended or altered whenever a floor is redesigned and walls are re-drawn to maintain continued protection. correct answers True The Fire Code contains some Standpipe System requirements, such as that Standpipe Systems must be installed in correct answers Buildings located where the street is of sub-standard width The Standpipe System must undergo a hydrostatic pressure test every ___________ years under the supervision of a ____________________________. a. 3/Master Plumber b. 5yrs/Master Fire Suppression Piping Contractor (MFSPC) having a Certificate of Fitness S-12 C. 5yrs/Master Fire Suppression Piping Contractor (MFSPC) d. 3yrs/Certificate of Fitness S-12 correct answers 5 years, Master Fire Suppression Piping Contractor (MFSPC) having a Certificate of Fitness S-12 Who is ultimately responsible for ensuring that the Standpipe System is fully functional at all times? correct answers Property Owner Records of inspections. tests and maintenance are mandated to be kept on the premises for a minimum period of__________________ years. correct answers 3years If a person is not designated as the property's Impairment Coordinator, who is considered the Impairment Coordinator? correct answers Building Owner Of the following certificates of fitness, which one is a citywide certificate? correct answers Sprinkler Systems S-12 Standpipe System S-13 An out of service condition caused by pipe break is considered a(n)... correct answers Unplanned out of service condition Who must be made aware to authorize an unplanned out of service condition affecting one floor correct answers No one Of the following, which one is NOT a serious defect in the Standpipe System? a. Major pipe break b. Low water pressure c. Defective Fire Department Connections d. Sign colored white on red posted next to the Fire Department Connection correct answers Sign colored white on red posted next to the Fire Department Connection
Geschreven voor
- Instelling
- S12/S13 Standpipe Sprinkler
- Vak
- S12/S13 Standpipe Sprinkler
Documentinformatie
- Geüpload op
- 28 mei 2024
- Aantal pagina's
- 7
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
standpipe systems primarily use a
Ook beschikbaar in voordeelbundel