ISA CCST Level III | 78 Questions and Answers(A+ Solution guide)
A Calibration procedure calls for checking a chemical cell oxygen analyzer daily. The range of the analyzer is 0 to 1000 PPM, and the procedure states that ambient air be used for the check. The chemical cell costs $350 and has a rated six months life. Cells are being replaced monthly.You Should: - A. Try to find a supplier of the sensor cells that is not as expensive. B. recommend a different type analyzer be used. C. recommend that a calibration system be installed using a 1000 PPM calibrating gas. D. continue the procedure. * In order to measure fluid flow with a Doppler type ultrasonic flow meter, the flowing stream must ____ to reflect the sonic pulses. - A. Contain particulate matter * B. Flow at a rate of 100 gallons per min, or more C. be conductive D. have a very low viscosity Transmitter steady state gain (output/input) should be ____ over it's entire range. - A. Variable B. constant * C. adjustable D. calibrated Most "smart" transmitter interface devices have a key pad with alpha-numeric keys, function keys and an LCD display. Display of the ____ is NOT available on the LCD display and cannot be changed. - A. transmitter piping and installation diagram * B. transmitter engineering data C. transmitter upper and lower input range values D. transmitter upper and lower output range values A fluid is flowing through a 12 inch diameter pipe at a velocity of 4 ft/sec. When the piping reduces to 6 inch diameter, and all other flowing paramters remain the same, the fluid velocity becomes ___ ft/sec. - A. 1 [Pipe Dia = √ (4 * flow rate)/(π * velocity)]B. 8 [velocity = (4 * flow rate)/(π *Pipe Dia2)] C. 16 [flow rate = 0.25 * π *Pipe Dia2 * velocity]* D. 24 (Find flow rate (3.14)and solve for ft 12.56/0.785) A 50 microampers meter with a 200 milivolt raiting is being used to check voltage. What multiplier resistor value must be used to obtain a 10 volt full scale range (in ohms)? - A. 20k V = I * R B. 196K R = V / I C. 200K I = V / R (10 / 0.00005)* D. 204K After controller settings are made using a process reaction curve method: - A. all settings must be documented for future use. B. the process should track set point with an exact precision. C. the process should be monitored for any necessary fine tuning. * D. the transmitter and control valve should be checked for calibration and accuracy. This electronic DP cell requires calibration to correct for the - A. zero error B. span error C. zero, span and linearity errors * D. linearity error A self tuning algorithm is particularly valuable when a ____ must be controlled. -A. non - linear process * B. high temperature C. absolute pressure D. oscillating flow The velocity of a fluid can be determined by dividing the ___? - A. viscosity of the fluid by the area of the pipe B. density of the fluidC. the rate of flow of the fluid by the area of the pipe * D. volume of the fluid
Voorbeeld van de inhoud
Geschreven voor
- Instelling
- ISA CCST Level III
- Vak
- ISA CCST Level III
Documentinformatie
- Geüpload op
- 20 september 2023
- Aantal pagina's
- 18
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
isa ccst level iii
Ook beschikbaar in voordeelbundel