100% tevredenheidsgarantie Direct beschikbaar na je betaling Online lezen of als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ISA CCST Level III | 78 Questions and Answers(A+ Solution guide)

Beoordeling
-
Verkocht
1
Pagina's
18
Cijfer
A+
Geüpload op
20-09-2023
Geschreven in
2023/2024

A Calibration procedure calls for checking a chemical cell oxygen analyzer daily. The range of the analyzer is 0 to 1000 PPM, and the procedure states that ambient air be used for the check. The chemical cell costs $350 and has a rated six months life. Cells are being replaced monthly.You Should: - A. Try to find a supplier of the sensor cells that is not as expensive. B. recommend a different type analyzer be used. C. recommend that a calibration system be installed using a 1000 PPM calibrating gas. D. continue the procedure. * In order to measure fluid flow with a Doppler type ultrasonic flow meter, the flowing stream must ____ to reflect the sonic pulses. - A. Contain particulate matter * B. Flow at a rate of 100 gallons per min, or more C. be conductive D. have a very low viscosity Transmitter steady state gain (output/input) should be ____ over it's entire range. - A. Variable B. constant * C. adjustable D. calibrated Most "smart" transmitter interface devices have a key pad with alpha-numeric keys, function keys and an LCD display. Display of the ____ is NOT available on the LCD display and cannot be changed. - A. transmitter piping and installation diagram * B. transmitter engineering data C. transmitter upper and lower input range values D. transmitter upper and lower output range values A fluid is flowing through a 12 inch diameter pipe at a velocity of 4 ft/sec. When the piping reduces to 6 inch diameter, and all other flowing paramters remain the same, the fluid velocity becomes ___ ft/sec. - A. 1 [Pipe Dia = √ (4 * flow rate)/(π * velocity)]B. 8 [velocity = (4 * flow rate)/(π *Pipe Dia2)] C. 16 [flow rate = 0.25 * π *Pipe Dia2 * velocity]* D. 24 (Find flow rate (3.14)and solve for ft 12.56/0.785) A 50 microampers meter with a 200 milivolt raiting is being used to check voltage. What multiplier resistor value must be used to obtain a 10 volt full scale range (in ohms)? - A. 20k V = I * R B. 196K R = V / I C. 200K I = V / R (10 / 0.00005)* D. 204K After controller settings are made using a process reaction curve method: - A. all settings must be documented for future use. B. the process should track set point with an exact precision. C. the process should be monitored for any necessary fine tuning. * D. the transmitter and control valve should be checked for calibration and accuracy. This electronic DP cell requires calibration to correct for the - A. zero error B. span error C. zero, span and linearity errors * D. linearity error A self tuning algorithm is particularly valuable when a ____ must be controlled. -A. non - linear process * B. high temperature C. absolute pressure D. oscillating flow The velocity of a fluid can be determined by dividing the ___? - A. viscosity of the fluid by the area of the pipe B. density of the fluidC. the rate of flow of the fluid by the area of the pipe * D. volume of the fluid

Meer zien Lees minder
Instelling
ISA CCST Level III
Vak
ISA CCST Level III

Voorbeeld van de inhoud

A Calibration procedure calls for checking a chemical cell oxygen analyzer daily. The range of the analyzer is 0 to 1000 PPM, and the procedure states that ambient air be used for the check. The chemical cell costs $350 and has a rated six months life. Cells are being replaced monthly.You Should: - ✔✔ A. Try to find a supplier of the sensor cells that is not as expensive. B. recommend a different type analyzer be used. C. recommend that a calibration system be installed using a 1000 PPM calibrating gas. D. continue the procedure. * In order to measure fluid flow with a Doppler type ultrasonic flow meter, the flowing stream must ____ to reflect the sonic pulses. - ✔✔ A. Contain particulate matter * B. Flow at a rate of 100 gallons per min, or more C. be conductive D. have a very low viscosity Transmitter steady state gain (output/input) should be ____ over it's entire range. - ✔✔ A. Variable B. constant * C. adjustable D. calibrated Most "smart" transmitter interface devices have a key pad with alpha -numeric keys, function keys and an LCD display. Display of the ____ is NOT available on the LCD display and cannot be changed. - ✔✔ A. transmitter piping and installation diagr am * B. transmitter engineering data C. transmitter upper and lower input range values D. transmitter upper and lower output range values A fluid is flowing through a 12 inch diameter pipe at a velocity of 4 ft/sec. When the piping reduces to 6 inch diame ter, and all other flowing paramters remain the same, the fluid velocity becomes ___ ft/sec. - ✔✔ A. 1 [Pipe Dia = √ (4 * flow rate)/( π * velocity)] B. 8 [velocity = (4 * flow rate)/(π *Pipe Dia2)] C. 16 [flow rate = 0.25 * π *Pipe Dia2 * velocity]* D. 24 ( Find flow rate (3.14)and solve for ft 12.56/0.785) A 50 microampers meter with a 200 milivolt raiting is being used to check voltage. What multiplier resistor value must be used to obtain a 10 volt full scale range (in ohms)? - ✔✔ A. 20k V = I * R B. 196K R = V / I C. 200K I = V / R (.00005)* D. 204K After controller settings are made using a process reaction curve method: - ✔✔ A. all settings must be documented for future use. B. the process should track set point with an exact precision. C. the process should be monitored for any necessary fine tuning. * D. the transmitter and control valve should be checked for calibration and accuracy. This electronic DP cell requires calibration to correct for the - ✔✔ A. zero error B. span error C. zer o, span and linearity errors * D. linearity error A self tuning algorithm is particularly valuable when a ____ must be controlled. - ✔✔ A. non - linear process * B. high temperature C. absolute pressure D. oscillating flow The velocity of a fluid can be d etermined by dividing the ___? - ✔✔ A. viscosity of the fluid by the area of the pipe B. density of the fluid C. the rate of flow of the fluid by the area of the pipe * D. volume of the fluid When tuning a cascade control loop, the slave controller needs _ __? - ✔✔ A. proportional response only * B. proportional plus integral response C. proportional, integral, and derivative D. proportional plus derivative A controller gain setting is greater than "1": You would expect its respons to be similar to a control ler with ____ proportional band. - ✔✔ A. a narrow * B. no C. direct D. wide Reset or integral control action is usually combined with proportional control action to eliminate ____. - ✔✔ A. cycles B. offset * C. overshoot D. slow response The conversion accuracy of a 10 -bit analog -to-digital converter is__________? - ✔✔ A. 0.98% of Measurement B. 0.098% of Measurement C. 0.098%FS * D. 0.98%FS Computer -aided calibration systems (CAC) execute a program in order to______? - ✔✔ A. Collect statis tical process data B. Reset controller set points

Geschreven voor

Instelling
ISA CCST Level III
Vak
ISA CCST Level III

Documentinformatie

Geüpload op
20 september 2023
Aantal pagina's
18
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€8,00
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Online lezen of als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Brainarium Delaware State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1885
Lid sinds
2 jaar
Aantal volgers
1044
Documenten
22712
Laatst verkocht
2 uur geleden

3,8

326 beoordelingen

5
151
4
62
3
55
2
16
1
42

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen