What is a cad cell? - Answer- Visual flame detector What does "in-step" mean? - Answer- The primary control start circuit is closed What is the voltage found at the TT terminals? - Answer- 24 volts What are the 8 steps on a no heat call? - Answer- Main fuse, oil burner fuse, customer emergency switch, oil tank, oil valves, high limit, thermostat, primary control. How much air is necessary to burn a gallon of #2 fuel oil? - Answer- 1540 cubic ft What is the normal pump pressure? - Answer- 100 psi How is combustion achieved? - Answer- Proper amount of oil, air, and ignition What is primary air? - Answer- Air mixed with oil before the nozzle. It is the atomizing air found on in low pressure burners. What is secondary air? - Answer- Fan air Does firbebrick come in different heat ratings? - Answer- Yes How should an oil tank be supported? - Answer- Rigid, non-combustable supports What is the wire gauged used on oil burner circuits? - Answer- 14 gauge min How is an oil burner wired? - Answer- Series; intermittent or interrupted. What does intermittent mean? - Answer- The transformers stays on throughout the burner cycle What does interrupted mean? - Answer- The transformer drops out after flame is established. Who approves oil burners in MA? - Answer- Any approved national testing lab What does the term Marshall mean? - Answer- State Fire Marshall What size vent pipe is required with a 2 inch fill pipe? - Answer- 2" min Can a vent pipe on an oil tank be smaller than the fill? - Answer- No, it can be larger but not smaller What is the minimum size of vent and fill pipes? - Answer- 1 1/4" Explain interrupted ignition - Answer- Transformer drops out after the flame is established What permits are available? - Answer- Install, store oil, and tank removal What are the elements found in fuel oil? - Answer- 85% Carbon and 15% Hydrogen What is fuel oil? - Answer- Hydro-carbon How must fuel oil be prepared for combustion? - Answer- It is atomized or vaporized and mixed with air What is a BTU? - Answer- The amount of heat necessary to rain 1 lb of water 1 degree Fahrenheit How many BTU's are in a gallon of #2 fuel oil? - Answer- 140,000 What determines the GPH of a nozzle? - Answer- The orifice What is a series circuit? - Answer- the current has only one path to travel What is a degree day? - Answer- 65 degrees F minus the daily average temp What is the flash point of #2 fuel oil? - Answer- 110 degrees Fahrenheit Can materials other than steel be used for fuel oil tanks? - Answer- Yes, if approved What does the word "approved" mean? - Answer- Accepted b y the Marshall of by the laboratory which is accepted by the Marshall When is a combustion efficiency test required by law? - Answer- After installs and routine maintenances What control shorts off the oil burner in the event of excessive temp in the appliance - Answer- High limit Name 3 functions of an oil pump? - Answer- Pick-up, pressurize, and strain oil How is an oil burner wired - Answer- Intermittent or interrupted How is an oil burner circuit wired? - Answer- Series When does an oil line have to be sleeved? - Answer- When it is buried or in contact with earth or cement What is the exception to overhead fireproofing? - Answer- Any AFUE (annualized fuel utilization efficiency) rated appliance What does "in-step" mean? - Answer- The primary control start circuit is closed What is the minimum size oil lines for residential burners - Answer- 3/8" OD, 3/8" IPS Is a permit required for the removal of an oil tank? - Answer- Yes Cross connections between two supply tanks shall not exceed ____________ gallons total. - Answer- 660 How is safety timing checked on a stack switch? - Answer- Remove the switch from its holder or disconnect terminal three, fire unit, and time its lockout. What is safety lockout timing firing under 3 GPHV ? - Answer- 15 seconds maximum. Is a combustion test required for tank replacement? - Answer- No Where should a thermal valve be installed on a supply line from the tank? - Answer- Connected at the bottom of the supply tank. What is a cadmium sulfide cell? - Answer- A resistor which changes its characteristics of conductivity in a direct proportion to the light striking it. What is the minimum size pipe that can be used for residential oil lines, and can right and left couplings be used? - Answer- 3/8" OD and 3/8" IPS minimum and right and left couplings are forbidden. What safety devices are found on a rotary burner? - Answer- A constant level valve and a solenoid valve. How is the oil flow regulated on a rotary burner? - Answer- The constant level valve When is a vent alarm used? - Answer- When gauge is not visible from fill When is a vent pipe required - Answer- All tanks that are larger than 10 gallons What must be done after an installation has been completed? - Answer- Submit a certificate of completion. When should your oil burner install certificate of completion be submitted? - Answer- Local fire department What is the time limit for submitting certificates of completion? - Answer- 72 hrs, excluding Saturday, Sunday, and all holidays. What is a confined space? - Answer- Less than 50 cu. ft. per 1,000 BTU's What is a gallon? - Answer- 231 cu. in. at a temp of 60 degrees Fahrenheit What are the element in air? - Answer- Nitrogen 80% or 79% Oxygen 20% or 21% How much air is required to burn a gallon of #2 fuel oil and why? - Answer- 1540 cu. ft.; This is the most amount of air needed to burn all the oil most efficiently. What kind of counts are used on oil tank installs? - Answer- Swing joints What are swing joints used on oil tanks? - Answer- To allow for movement or settlings without pipe or tank damage, and to enable piping to pitch back to tanks. What is the minimum distance that a burner must be from a tank? - Answer- 5' How many gallons of oil may be stored without a permit? - Answer- 10 gallons How much outside or replacement air is needed in a confined space - Answer- 140 sq." top and bottom per gallon per hour 1 sq." per 1000 BTU's How much outside or replacement air is needed in a boiler room of tight construction? - Answer- 28 sq." per gallon per hour 1 sq." per 5,000 BTU's What is a flame detector? - Answer- A device that sense flame thermally or visually What is a cad cell? - Answer- A visual flame sensor What is a purpose of a heat anticipator? - Answer- Prevents overheating Explain the differentials in a thermostat. - Answer- Mechanical - the operation of the helix; turns the appliance on and off Electrical - operation of the anticipator; prevents overheating What are the parts of an ignition assembly? - Answer- High voltage transformer, buss bars or high tension leads, insulators, and electrodes.

Meer zien Lees minder
Instelling
Oil Burner
Vak
Oil Burner









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Oil Burner
Vak
Oil Burner

Documentinformatie

Geüpload op
29 mei 2023
Aantal pagina's
6
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,11
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Gordones22 Yala university
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
498
Lid sinds
3 jaar
Aantal volgers
351
Documenten
9500
Laatst verkocht
2 weken geleden

4,1

108 beoordelingen

5
63
4
17
3
13
2
4
1
11

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via Bancontact, iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo eenvoudig kan het zijn.”

Alisha Student

Veelgestelde vragen