ShantelleG
HELLO? welcome to my store
thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless .
DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU
ALSO REFER YOUR FRIENDS.
- 10251
- 0
- 661
Community
- Abonnés
- Abbonements
56 Avis reçus
10947 éléments
HVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLE
HVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(
- Pack
- • 40 éléments •
- HVAC Final Exam Electrical For Air Conditioning Accurate 100% • Examen
- HVAC Electrical Final Test • Examen
- HVAC Final Exam Correct Questions & Answers(RTED A) • Examen
- HVAC Final Exam Complete Questions & Answers!! • Examen
- HVAC final exam, unit 15 Correct 100% • Examen
- Et plus ….
HVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(FULL SOLUTIONS PACK!!!)EXAM BUNDLEHVAC Final Exam Electrical For Air Conditioning Accurate 100%(
HVAC Final Quizlet 1, HVAC Final Questions & Answers!!!
Evaporator Coil - ANSWER What component of an air conditioning system absorbs heat into the refrigerant 
 
Ventilation - ANSWER What does the V stand for in HVAC? 
 
Hot Surface Ignition - ANSWER What type of ignition is utilized by the furnaces in the shop? 
 
Air Conditioning - ANSWER What is the term for Refrigeration applied to the space temperature of a building? 
 
Electricity, L.P., Natural Gas - ANSWER What are the
- Package deal
- Examen
- • 4 pages •
Evaporator Coil - ANSWER What component of an air conditioning system absorbs heat into the refrigerant 
 
Ventilation - ANSWER What does the V stand for in HVAC? 
 
Hot Surface Ignition - ANSWER What type of ignition is utilized by the furnaces in the shop? 
 
Air Conditioning - ANSWER What is the term for Refrigeration applied to the space temperature of a building? 
 
Electricity, L.P., Natural Gas - ANSWER What are the
Electricity for HVAC REVIEW Practice Test 3 True or False Correct 100%
True - ANSWER Copper wire bend easily, has good mechanical strength, resists corrosion, and can be easily joined. 
 
True - ANSWER Aluminum is a good conductor of electricity, however, it has a tendency to corrode. 
 
False - ANSWER Voltage drop in a conductor is of least importance when sizing wire. 
 
False - ANSWER The maximum recommended voltage drop for a branch circuit is eight percent. 
 
False - ANSWER The allowable voltage drop of most manufacturers is 15% below the nameplate rating. 
 ...
- Package deal
- Examen
- • 3 pages •
True - ANSWER Copper wire bend easily, has good mechanical strength, resists corrosion, and can be easily joined. 
 
True - ANSWER Aluminum is a good conductor of electricity, however, it has a tendency to corrode. 
 
False - ANSWER Voltage drop in a conductor is of least importance when sizing wire. 
 
False - ANSWER The maximum recommended voltage drop for a branch circuit is eight percent. 
 
False - ANSWER The allowable voltage drop of most manufacturers is 15% below the nameplate rating. 
 ...
HVAC Journeyman Questions & Answers!!
Three tons of air conditioning is equal to how many BTUs? - ANSWER 36,000 
 
The liquid line size is _______. - ANSWER 3/8" 
 
The discharge line should feel _____ to the touch. - ANSWER slightly warm 
 
The compressor should be on a level pad _____ inches above grade. - ANSWER 3 
 
The electrical disconnect should be in direct line of sight and no more than ____ feet away from the compressor/condenser cabinet. - ANSWER 50 
 
Insulation is wrapped around the: - ANSWER suction line 
 
Frost on t...
- Package deal
- Examen
- • 2 pages •
Three tons of air conditioning is equal to how many BTUs? - ANSWER 36,000 
 
The liquid line size is _______. - ANSWER 3/8" 
 
The discharge line should feel _____ to the touch. - ANSWER slightly warm 
 
The compressor should be on a level pad _____ inches above grade. - ANSWER 3 
 
The electrical disconnect should be in direct line of sight and no more than ____ feet away from the compressor/condenser cabinet. - ANSWER 50 
 
Insulation is wrapped around the: - ANSWER suction line 
 
Frost on t...
HVAC journeyman prep test Correct 100%
A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall - ANSWER Corridor wall (IMC 607.5.4) 
 
Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' - ANSWER 14' (IMC 603.6.1.1) 
 
The maximum vertical distance between the front lower lip of a canopy Type 1 hood and the appliance surface shall be ____ feet: (A)5' (B)3' ...
- Package deal
- Examen
- • 12 pages •
A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall - ANSWER Corridor wall (IMC 607.5.4) 
 
Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' - ANSWER 14' (IMC 603.6.1.1) 
 
The maximum vertical distance between the front lower lip of a canopy Type 1 hood and the appliance surface shall be ____ feet: (A)5' (B)3' ...
HVAC Star Exam Correct Questions & Answers!!
In a chiller, the refrigerant boils by ___________. - ANSWER absorbing heat from the water passing through it 
 
The four main components of a refrigeration system are - ANSWER compressor, condenser, evaporator, & metering device 
 
The difference between a contactor and a motor starter is: - ANSWER overload protection 
 
If refrigerant condenses at a temperature of 105 degrees F and the water leaves the condenser at a temperature of 95 degrees F, the ___________. - ANSWER condenser approach tem...
- Package deal
- Examen
- • 9 pages •
In a chiller, the refrigerant boils by ___________. - ANSWER absorbing heat from the water passing through it 
 
The four main components of a refrigeration system are - ANSWER compressor, condenser, evaporator, & metering device 
 
The difference between a contactor and a motor starter is: - ANSWER overload protection 
 
If refrigerant condenses at a temperature of 105 degrees F and the water leaves the condenser at a temperature of 95 degrees F, the ___________. - ANSWER condenser approach tem...
HVACR Practice Test Correct 100% What is the symbol for impedance? a. R b. I c. Z d. P - ANSWER z The safety ground conductor for A/C circuit is usually color coded ________. a. red b. green c. black d. white - ANSWER Green Resistance is _______. a. a
HVACR Practice Test Correct 100% 
 
 
What is the symbol for impedance? 
a. R 
b. I 
c. Z 
d. P - ANSWER z 
 
The safety ground conductor for A/C circuit is usually color coded ________. 
a. red 
b. green 
c. black 
d. white - ANSWER Green 
 
Resistance is _______. 
a. amperage 
b. electrical pressure 
c. opposition to current flow 
d. voltage applied to the circuit - ANSWER opposition to current flow 
 
How many watts of power are used by a heater operating at 480 volts and drawing 5 amps? 
a. ...
- Package deal
- Examen
- • 2 pages •
HVACR Practice Test Correct 100% 
 
 
What is the symbol for impedance? 
a. R 
b. I 
c. Z 
d. P - ANSWER z 
 
The safety ground conductor for A/C circuit is usually color coded ________. 
a. red 
b. green 
c. black 
d. white - ANSWER Green 
 
Resistance is _______. 
a. amperage 
b. electrical pressure 
c. opposition to current flow 
d. voltage applied to the circuit - ANSWER opposition to current flow 
 
How many watts of power are used by a heater operating at 480 volts and drawing 5 amps? 
a. ...
Hvac Journeyman Exam Correct Questions & Answers
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - ANSWER B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every absorption refrigerating system supported from the ground shall rest on a concrete slab extending not less than _____ the adjoining ground level.(A) 3 inches below(B) 3 inches above (C) 6 inches below(D)...
- Package deal
- Examen
- • 10 pages •
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - ANSWER B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every absorption refrigerating system supported from the ground shall rest on a concrete slab extending not less than _____ the adjoining ground level.(A) 3 inches below(B) 3 inches above (C) 6 inches below(D)...
HVACR Journeyman Practice Exam Accurate 100%
In a (direct expansion) evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: - ANSWER Operate at High Efficiency. 
 
What is one of the main reasons that reciprocating compressors are not 100% efficient? - ANSWER Clearance Volume 
 
A dirty evaporator and return air filters subsequently causes low evaporator pressures which will cause - ANSWER High Compression Ratios 
 
The automatic expansion valve (AEV) maintains a constant ______ in the evapor...
- Package deal
- Examen
- • 3 pages •
In a (direct expansion) evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: - ANSWER Operate at High Efficiency. 
 
What is one of the main reasons that reciprocating compressors are not 100% efficient? - ANSWER Clearance Volume 
 
A dirty evaporator and return air filters subsequently causes low evaporator pressures which will cause - ANSWER High Compression Ratios 
 
The automatic expansion valve (AEV) maintains a constant ______ in the evapor...
ACR-120 Basic A/C Final Exam Correct 100%
1. The correct way to short capacitor terminals before checking a capacitor with an ohmmeter is to use a _______ ohm resistor. - ANSWER 20,000 
 
2. Fractionation occurs when __________ - ANSWER some of a blended refrigerant evaporates or condenses before the rest of the blend. 
 
3. Refrigerant in vapor form is normally put into the system through the ______. - ANSWER suction line. 
 
4. When charging a system with vapor refrigerant from a refrigerant cylinder, the cylinder will become ________...
- Package deal
- Examen
- • 6 pages •
1. The correct way to short capacitor terminals before checking a capacitor with an ohmmeter is to use a _______ ohm resistor. - ANSWER 20,000 
 
2. Fractionation occurs when __________ - ANSWER some of a blended refrigerant evaporates or condenses before the rest of the blend. 
 
3. Refrigerant in vapor form is normally put into the system through the ______. - ANSWER suction line. 
 
4. When charging a system with vapor refrigerant from a refrigerant cylinder, the cylinder will become ________...
Wall Street Prep Financial Statement Modeling Correct 100%
Nevada Life & Health Review Correct Questions & Answers!!
Nevada Life and Health Complete Questions & Answers 100% Accurate
this is hard to navigate I dont have all day to skim 50 pages for the right questions and answers!
AP Bio Practice Exam 1 With Complete Questions And Answers
Michigan life insurance state exam answer key Correct 100%