How much extra refrigerant con be stored in a machine room?
A) 330 lbs.
B) The amount equal to the design pressure.
C) 20% above normal charge.
D) 220 lbs. - Correct Answer - C) 20% above normal charge.


A refrigeration compressor has failed to turn on. The refrigeration
engineer on duty verifies that the electrical circuit to the motor,
including all switches and circuit breakers, is complete according to
recommended service practice. The next item to be checked would likely
by the
A) temperature and pressure controls.
B) refrigerant charge.
C) cooling tower operation.
D) liquid-line solenoid valve. - Correct Answer - A) temperature and
pressure controls.


The use of oil in the refrigeration machine is to
A) Add non-condensates to refrigerant.
B) Mix the oil with liquid refrigerant.

pg. 1

,C) Reduce wear and friction in compressor parts.
D) None of the answers are correct. - Correct Answer - C) Reduce wear
and friction in compressor parts.


The heat removed from the refrigerant condenser is
A) latent heat only.
B) sensible heat only.
C) sensible and latent heat.
D) Radiant heat only. - Correct Answer - C) sensible and latent heat.


Which service valve should be installed in a dual pressure release valve
while keeping system in service?
A) Two-way valve.
B) Plug valve.
C) Three-way valve.
D) Stop valve. - Correct Answer - C) Three-way valve.


The monthly quick check of a fire extinguisher does NOT include
A) Checking the extinguisher for damage.
B) Confirming its proper location.
C) Discharging the extinguisher.
D) Ensuring it is clear from any obstructions. - Correct Answer - C)
Discharging the extinguisher.



pg. 2

,Several components of a sprinkler system in an office building need to
be repaired. Which of the following are allowed to perform the repair
work?
A) A Q-01 refrigeration engineer holding S-12 CoF.
B) A Master Fire Suppression Contractor holding S-12 CoF.
C) Any Master Fire Suppression Piping Contractor.
D) A S-12 CoF holder without any other license. - Correct Answer - B) A
Master Fire Suppression Contractor holding S-12 CoF.


A FDNY permit is required to conduct hot work for
A) brazing.
B) welding.
C) use of oxygen and flammable gas.
D) All answers are correct - Correct Answer - D) All answers are correct


Which of the following correctly describes the object in the picture
below?
A) Carbon dioxide system nozzle, to extinguish electrical fires.
B) Cooling tower makeup valve, to put out fires in case of emergency.
C) Standpipe hose outlet, to put out fires in case of emergency.
D) Water chemistry supply station, for condenser water. - Correct
Answer - C) Standpipe hose outlet, to put out fires in case of emergency.




pg. 3

, While on duty, a refrigerant engineer notices that the suction line to the
compressor and part of the compressor is frosted. Of the following, the
most likely reason for this condition is
A) the TEV is almost closed.
B) overcharge.
C) there is a blockage in the liquid line
D) low condenser water temperature. - Correct Answer - B) overcharge.


You find that the check valve on a centrifugal pump is leaking. When
will the most damage be caused to the pump?
A) When another pump is turned on.
B) On shutdown.
C) When servicing the pump.
D) On startup. - Correct Answer - D) On startup.


What is the lowest temperature the water in the cooling tower can be?
A) Ambient.
B) Between wet and dry bulb.
C) Dry bulb.
D) Wet bulb. - Correct Answer - B) Between wet and dry bulb.


The most important reason to subcool the refrigerant in the condenser is
to ensure that
A) liquid slugs will not enter the compressor.


pg. 4

Infos sur le Document

Publié le
3 juillet 2025
Nombre de pages
49
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses
17,28 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
ASSIGNMENT7
3,9
(181)
Vendu
981
Abonnés
29
Éléments
3884
Dernière vente
19 heures de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions