Efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the
following, a more efficient centrifugal compressor operation results from:

Lowering the condensing pressure

The heat removed from the refrigerant in a condenser is:

Sensible and latent heat

The refrigerant unit that you have been assigned to is being taken out of service for a
major repair. You have been assigned to withdraw refrigerant for storage in suitable
containers. According to the NYC Fire Code, you must ensure that the containers:

Are approved by the US Dept. of Transportation

Which of the following best describes how the cylinder unloader works?

Keep in the suction valve opened while the compressor is in the return stroke

In most semi-hermetic compressors, the suction vapor is used to:

Cool the motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the:

Differences between the high side and low side pressure

The installation of an inline refrigerant cleaning system is advisable:

To remove impurities from the system

The type of refrigerant system that is least likely to leak refrigerant into the building space
that are being cooled:

Indirect system

,The suction pressure of a reciprocating compressor is 65 PSIG. The discharge pressure of
this compressor is 120 PSIG. The atmospheric is 14.7 PSI. The compression ratio for the
given condition is closest to:

1.69

A superheated vapor is:

Dry vapor above the saturation temperature

A refrigerant engineer verifies that a condenser water pump is cavitating. Of the following,
the most likely cause for this condition is:

A faulty cooling tower water level controller

A centrifugal water pump is known as a lift pump when the:

The water supply to the pump suction inlet is below the pump level

A TXV is used to maintain constant:

Evaporator superheat

The chilled water supply to the building is 55 deg F. If the chiller is being used for human
comfort, should you be concerned about this, and why?

Yes, this temp is too high for human comfort purposes

The packing gland of a centrifugal pump serves to:

The drip part of the packing gland gives evidence that there is water in the pump

Capacity control of reciprocating hermetic compressor is typically achieved through:

Operation of the hot gas bypass valve

The most important reason to sub-cool the refrigerant in the condenser is to ensure that:

A pure liquid refrigerant will enter the metering device

, A refrigeration engineer is logging readings from a reciprocating system. Compressor
discharge temperature have dropped significantly and the suction line pressure is high.
Which of the following that may be causing this set of condition?

An expansion valve that is open too wide

A low side float valve is used to maintain:

The level of the refrigerant in the evaporator

Regarding fire safety, which ASHRAE refrigerant safety classification indicates no
flammability and lower toxicity?

A1

When an expansion valve is operating properly, at the end of the evaporator will contain:

Only superheated vapor

What information is not contained in a Material Safety Data Sheet?

Cost of the material

In a steam turbine, what is the function of the Kingsbury thrust bearing?

Maintain axial positioning of the rotor shaft

A centrifugal water pump is considered to the fully primed when?

The pump is full of liquid

Copper tubing refrigerant lines must be installed for a new system. It is a well known
service practice that tubing collapses at bends that must be made, the refrigerant engineer
should use?

Level type tubing bender

A reciprocating compressor is making a knocking sound during operation. If the
refrigerant worn parts are not causing the knocking, what probably the cause?

Slugging of the liquid refrigerant

Infos sur le Document

Publié le
26 mai 2025
Nombre de pages
27
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses
12,40 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
QUINTER
3,6
(73)
Vendu
410
Abonnés
106
Éléments
39858
Dernière vente
1 semaine de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions