NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY QUESTIONS WITH REVISED ANSWERS NEW UPDATE GUARANTEED PASS | RATED A+ A pathway shall be designated as Class when it does not include a redundant path and operational capability stops at a single open and operational capability is maintained during the application of a single ground fault? - Answer Class B EMT shall be securely fastened in place at least every feet. - Answer 10 feet The minimum clear safe working distance from an energized 240 volt breaker panel that has the cover removed is ft from the wall in front the panel. - Answer 3 feet Wall mounted audible appliances shall have their tops above the finished floors at heights of not less than inches and below the finished ceilings at distances of not less than 6 inches? - Answer 90 inches A minimum db ambient sound level with a 6 hour exposure time requires hearing protection? - Answer 92 db Ground fault circuit interrupters are required for all 120 volts power tools on a construction site unless . - Answer The work area is dry Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the positive leg of a fire alarm circuit is metered to a known ground with the meter set to the 10kohm setting. Consider that the circuit is properly functioning. The expected reading on the multimeter is ohms? - Answer Infinity Including new systems and addition or alterations to existing systems, which of the following is not required to be delivered to the owner upon final acceptance of the system? - Answer Inspection & Testing records, Central station history log According to NFPA 72, section of the record of completion is used to note the input voltage? - Answer Section 5.1.11 Which of the following is not one of the criteria to be a designated a confined space? - Answer A room that locks when the door is closed. According to NFPA 72 the onsite location of the required record documents and specific software is notes in section of the Record of Completion? - Answer Section 3 According to NFPA 72 the Record of Completion section 12.1 is required to be signed by ? - Answer System Installation Contractor

Aperçu du contenu

NICET LEVEL 1 FIRE ALARM SYSTEMS EXAM STUDY
QUESTIONS WITH REVISED ANSWERS NEW UPDATE
GUARANTEED PASS | RATED A+

A pathway shall be designated as Class when it does not include a redundant path and
operational capability stops at a single open and operational capability is maintained during the
application of a single ground fault? - Answer>>> Class B

EMT shall be securely fastened in place at least every feet. - Answer>>> 10 feet
The minimum clear safe working distance from an energized 240 volt breaker panel that has
the cover removed is ft from the wall in front the panel. - Answer>>> 3 feet
Wall mounted audible appliances shall have their tops above the finished floors at heights of
not less than inches and below the finished ceilings at distances of not less than 6 inches?
- Answer>>> 90 inches

A minimum db ambient sound level with a 6 hour exposure time requires hearing
protection? - Answer>>> 92 db

Ground fault circuit interrupters are required for all 120 volts power tools on a construction site
unless . - Answer>>> The work area is dry

Consider the use of a multimeter in troubleshooting a fire alarm circuit. The circuit has an end
of the line resistor with a value of 4.7ohms. With the circuit disconnected from power, the
positive leg of a fire alarm circuit is metered to a known ground with the meter set to the
10kohm setting. Consider that the circuit is properly functioning. The expected reading on the
multimeter is ohms? - Answer>>> Infinity

Including new systems and addition or alterations to existing systems, which of the following is
not required to be delivered to the owner upon final acceptance of the system? - Answer>>>
Inspection & Testing records, Central station history log

According to NFPA 72, section of the record of completion is used to note the input voltage? -
Answer>>> Section 5.1.11

Which of the following is not one of the criteria to be a designated a confined space? -
Answer>>> A room that locks when the door is closed.

, According to NFPA 72 the onsite location of the required record documents and specific
software is notes in section of the Record of Completion? - Answer>>> Section 3

According to NFPA 72 the Record of Completion section 12.1 is required to be signed
by ? - Answer>>> System Installation Contractor

What is the minimum size grounding conductor that cab be used when wiring a fire alarm
control panel to a 20 amp. Breaker? - Answer>>> #12

The location of the branch circuit overcurrent protective device shall be permanently identified
at the fire alarm control unit . Which of the following is a requirement of the circuit
disconnecting means? Select Three - Answer>>> 1.Red identification 2.Accessible only to
qualified personnel 3.Identified as FIRE ALARM CIRCUIT

The secondary power supply should automatically provide power to protect premises system
within seconds Whenever the primary power supply voltage is insufficient for required
systems operation. - Answer>>> 10 seconds

Consider a fire alarm system which does not use an uninterruptible power supply for primary
power. Independent and reliable power supply shall be provided? - Answer>>> 2
independent

You are using a power tool that has a 3 prong (grounded) plug. The only outlets available are 2
prong (non grounded). What can be done? - Answer>>> Locate a 3 prong plug or used a tool
with a 2 prong plug.

The power source for a power limited fire alarm circuit shall be a listed PLFA or Class
transformer? - Answer>>> Class 3 transformer

Which of the following is a symptom of heat stroke? - Answer>>> Red skin, Elevated Body
Temperature, Rapid, Weak pulse

The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is ?-
Answer>>> 4

The distance between smoke detectors shall not exceed a nominal spacing of feet? -
Answer>>> 30 feet

A portable ladder shall support at least times the maximum intended load. - Answer>>>

Infos sur le Document

Publié le
29 décembre 2024
Nombre de pages
11
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses
13,76 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
EXCELLENCE8HUB
4,4
(14)
Vendu
64
Abonnés
17
Éléments
1640
Dernière vente
4 semaines de cela




Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions