Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Document preview thumbnail
Aperçu 2 sur 13 pages
Examen

NICET Level 1 Fire Alarm Systems complete test exam (Latest 2024/ 2025 Qs & As| 100% Correct| Grade A+ (Verified Answers)

Document preview thumbnail
Aperçu 2 sur 13 pages

NICET Level 1 Fire Alarm Systems complete test exam (Latest 2024/ 2025 Qs & As| 100% Correct| Grade A+ (Verified Answers) NICET Level 1 Fire Alarm Systems complete test exam (Latest 2024/ 2025 Qs & As| 100% Correct| Grade A+ (Verified Answers)

Aperçu du contenu

NICET Level 1 Fire Alarm Systems
complete test exam (Latest
2024/ 2025 Qs & As| 100%
Correct| Grade A+ (Verified
Answers)


The operable part of a manually actuated alarm initiating device shall be not less
than inches AFF. CORRECT>>42 inches

Consider the use of grounding electrodes. Rod and pipe electrodes shall not be
less than feet in length? CORRECT>>8 feet

Smoke detectors should not be located in a direct airflow or closer than
inches from an air supply diffuser or return air opening? - Answer 36 inches

Consider the use of visible notification appliances. Wall mounted appliances shall
be mounted such that the entire lens is not less than inches above the
finished floor? CORRECT>>80 inches

How many 16 gauge conductors are permitted in a 4 x 1 1/2 inches square box?
CORRECT>>12

Wall mounted audible appliances shall have their tops above the finished floors at
heights of not less than inches and below the finished ceilings at distances of
not less than 6 inches? CORRECT>>90 inches

A minimum db ambient sound level with a 6 hour exposure time requires
hearing protection? CORRECT>>92 db

Spot type heat sensing fire detectors shall be located on the ceiling not less than
inches from the sidewall. CORRECT>>4 inches

While operating an aerial lift, the use of a body harnes and is not required?
CORRECT>>Stabilizer Hook, Grounding Pole, Insulation Mat

, Spot type smoke detectors shall be located on the ceiling or, if on a sidewall,
between the ceiling and inches down from the ceiling to the top of the
detector. CORRECT>>12 inches

The distance between spot type heat detectors shall not exceed their listed
spacing, and there shall be detectors within a distance of the listed spacing,
measured at right angles from the walls? CORRECT>>One Half

Where partitions extend to within percent of the ceiling height, the spaces
separated by the partitions shall be considered as separate rooms?
CORRECT>>15 percent

Consider 1,000 feet total of 18 gauge soild coated copper at 167o Fahrenheit. The
resistance of this conductor is ohm? CORRECT>>8.08 ohm

Consider the installation of heat detectors on a ceiling with beams. A ceiling shall
be treated as a smooth ceiling if the beams project no more than inches
below the ceiling? CORRECT>>4 inches

Which of the following conductor types is an acceptable substitute for FPLR?
CORRECT>>FPLP, CMP

Consider the use of PLFA fire alarm cable. The size of conductors in
multiconductor cable shall not be smaller than AWG? CORRECT>>26
AWG

You are using a power tool that has a 3 prong (grounded) plug. The only outlets
available are 2 prong (non grounded). What can be done? CORRECT>>Locate a 3
prong plug or used a tool with a 2 prong plug.

The power source for a power limited fire alarm circuit shall be a listed PLFA or
Class transformer? CORRECT>>Class 3 transformer

Which of the following is a symptom of heat stroke? CORRECT>>Red skin,
Elevated Body Temperature, Rapid, Weak pulse

The maximum number of 14 AWG, RHH conductors permitted in 1/2 inch EMT is
? CORRECT>>4

Infos sur le Document

Publié le
7 novembre 2024
Nombre de pages
13
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses
11,54 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
kiarienaomi88
3,7
(29)
Vendu
216
Abonnés
11
Éléments
3911
Dernière vente
23 heures de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions