RELIAS BASIC DYSRHYTHMIA REVIEW-ACTUAL EXAM SET 2024 UPDATED normal sinus rhythm (NSR) Criteria: (PR, QRS, QT, Rhythm: reg or irreg) - CORRECT ANSWER-1 P-wave for Every QRS, REGULAR rhythm PR: 0.12-0.20 QRS: 0.06-0.10 BBB = 0.12 QT: 0.36-0.44 BPM: 60-100 Sinus Bradycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWERPR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: 60 (Reg. rate) Tx: Atropine 0.5mg, Pace, Dopamine 2-10 mcg/kg/min, Epie 2-10 mcg/min Sinus Tachycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWERPR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: 100-150 (Reg. rate, P wave may merge with T-wave) Cause: fear, anxiety, hypoxia, sepsis, hypovolemia, infection Sinus Arrhythmia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWERPR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: HR increase w/ inspiration, HR decrease w/expiration P-P interval lengthen and shorten with respirations Irreg Rhythm NO TX Sinus Pause Criteria: (PR, QRS, QT, Rhythm) - CORRECT ANSWER-PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 Irregular rhythm Short Pause: no TX; Long/Freq. Pause & symptomatic = TX like Sinus Brady Premature Atrial Contraction (PAC) - CORRECT ANSWER-Heart Rate: Depends on underlying rhythm Regularity: Interrupts the regularity of underlying rhythm P-Wave: can be flattened, notched, or unusual. May be hidden within the T wave PRI: measures between .12-.20 seconds and can be prolonged; can be different from other complexes QRS: .12 seconds TX: none, check Lytes, precursor for A-Fib/Flutter Atrial Fibrillation (A-Fib) (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER-PR: Can't Measure *NO P WAVE* QRS: 0.06-0.10 QT: May/May Not be Measurable Rhythm: IRREGULARLY IRREGULAR Rate: Atrial 400 BPM Tx: Diltiazem (Cardizem), Amiodarone, Beta Blocker (Lopressor), Digoxin, Anti-Coag (Heparin), Cardiovert Atrial Flutter (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER-PR: Can't Measure *NO P WAVE* QRS: 0.06-0.10 QT: Can't Measure Rhythm: Ventricular Rate = Reg. Atrial = Irreg Atrial Rate 250-400 Ventricular: count QRS "Saw Tooth/Flutter Waves" Tx: Same as A-Fib

Aperçu du contenu

RELIAS BASIC DYSRHYTHMIA REVIEW -ACTUAL EXAM SET 2024 UPDATED normal sinus rhythm (NSR) Criteria: (PR, QRS, QT, Rhythm: reg or irreg) - CORRECT ANSWER -1 P-wave for Every QRS, REGULAR rhythm PR: 0.12 -0.20 QRS: 0.06 -0.10 BBB = > 0.12 QT: 0.36 -0.44 BPM: 60 -100 Sinus Bradycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWER -
PR: 0.12 -0.20 QRS: 0.06 -0.10 QT: 0.36 -0.44 BPM: < 60 (Reg. rate) Tx: Atropine 0.5mg, Pace, Dopamine 2 -10 mcg/kg/min, Epie 2 -10 mcg/min Sinus Tachycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWER -
PR: 0.12 -0.20 QRS: 0.06 -0.10 QT: 0.36 -0.44 BPM: 100 -150 (Reg. rate, P wave may merge with T -wave) Cause: fear, anxiety, hypoxia, sepsis, hypovolemia, infection Sinus Arrhythmia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) - CORRECT ANSWER -
PR: 0.12 -0.20 QRS: 0.06 -0.10 QT: 0.36 -0.44 BPM: HR increase w/ inspiration, HR decrease w/expiration P-P interval lengthen and shorten with respirations Irreg Rhythm NO TX Sinus Pause Criteria: (PR, QRS, QT, Rhythm) - CORRECT ANSWER -PR: 0.12 -0.20 QRS: 0.06 -0.10 QT: 0.36 -0.44 Irregular rhythm Short Pause: no TX; Long/Freq. Pause & symptomatic = TX like Sinus Brady Premature Atrial Contraction (PAC) - CORRECT ANSWER -Heart Rate: Depends on underlying rhythm Regularity: Interrupts the regularity of underlying rhythm P-Wave: can be flattened, notched, or unusual. May be hidden within the T wave PRI: measures between .12 -.20 seconds and can be prolonged; can be different from other complexes QRS: <.12 seconds TX: none, check Lytes, precursor for A -Fib/Flutter Atrial Fibrillation (A -Fib) (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER -PR: Can't Measure *NO P WAVE* QRS: 0.06 -0.10 QT: May/May Not be Measurable Rhythm: IRREGULARLY IRREGULAR Rate: Atrial >400 BPM Tx: Diltiazem (Cardizem), Amiodarone, Beta Blocker (Lopressor), Digoxin, Anti -Coag (Heparin), Cardiovert Atrial Flutter (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER -PR: Can't Measure *NO P WAVE* QRS: 0.06 -0.10 QT: Can't Measure Rhythm: Ventricular Rate = Reg. Atrial = Irreg Atrial Rate 250 -400 Ventricular: count QRS "Saw Tooth/Flutter Waves" Tx: Same as A -Fib paroxysmal atrial tachycardia (PAT) (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER -an episode that begins and ends abruptly during which there are very rapid and regular heartbeats that originate in the atrium PR: 0.12 -0.20 QRS: 0.06 -0.10 QT: 0.36 -0.44 Atrial Rate: 150 -250 Reg Vent Rate: 150 -250 Tx: Adenosine, Diltiazem, vagal, Cardiovert Premature Junctional Contraction (PJC) (PR, QRS, QT, RHYTHM, TX) - CORRECT ANSWER -Rate: Normal or accelerated 60 -100 P wave: *Inverted Before/After QRS, Absent* PR: 0.12 -0.20 QRS: normal 0.06 -0.10 QT: 0.36 -0.44 Conduction: normal rhythm: irregular: PICs occur early in cycle of baseline rhythm NO TX: check E -Lytes -an ectopic pacemaker in the AV Junction produces PJC's

Infos sur le Document

Publié le
16 janvier 2024
Nombre de pages
7
Écrit en
2023/2024
Type
Examen
Contenu
Questions et réponses
11,10 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
StudyCenter1
4,3
(29)
Vendu
230
Abonnés
91
Éléments
3849
Dernière vente
1 semaine de cela




Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions