Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Document preview thumbnail
Aperçu 2 sur 13 pages
Examen

General X-ray Machine Operator Exam Guide New 2026/2027 Questions and Professionally Verified Answers

Document preview thumbnail
Aperçu 2 sur 13 pages

This document contains questions and verified answers for General X-ray Machine Operator Exam Guide . It includes detailed explanations, revision-focused content, and exam preparation material suitable for 2026/2027 students.

Aperçu du contenu

General X-ray Machine Operator Exam
Guide

15% rule - ANS-states that converting the kilovoltage height by using 15% could have the same
impact on radiographic density as doubling the mAs or lowering the mAs via 50%

absorption - ANS-the method of shifting x-ray strength to the atoms of the material via which the
x-ray beam passes

delivered filtration - ANS-any filtration executed by way of additives lying past the housing port

AEC Automatic Exposure Control - ANS-A tool that measures the quantity of radiation
accomplishing the photo receptor and robotically terminates the exposure whilst the image
receptor has acquired the specified radiation intensity

The unmarried function is to eliminate the want for the radiographer to set an publicity time

ALARA - ANS-as low as resonably attainable

analog photo - ANS-Radiographic picture produced by means of traditional film

Analog to digital converter (ADC) - ANS-data despatched to computer for processing

Angle (tilt, roll) - ANS-Permits angulation of the tube alongside the longitudinal axis of the desk

anode - ANS-a definitely charged electrode through which electrons go away an electrical
device. It conducts power and radiates warmness and includes the goal.

Anode heel effect - ANS-Density is greater closer to the cathode aspect of the tube, and less
closer to the anode facet.
(thicker frame part towards cathode)

anode target - ANS-region of the anode struck by way of the electrons from the cathode

aperture diaphragm - ANS-It is a flat sheet of lead that has a hollow reduce in the middle and
connected to the x-ray tube port. The commencing may be made in any length or shape;
maximum are square, rectangular, or spherical and is the handiest of all beam-restricting
gadgets

, are anode interactions efficient? - ANS-no, ninety nine% are warmth and 1% is x-ray

artifact - ANS-portion of an photograph or tracing that doesn't accurately constitute the situation
of the photo or measurement being recorded

attenuation - ANS-the absorption of x-ray beam via matter

heritage radiation - ANS-comes from the solar and other planetary bodies and obviously
occurring radioactive substances present in the world (uranium and radium)

backup timer - ANS-Is the time the Electronic timer is about in case the AEC fails to terminate
publicity

beam limit - ANS-maintains the total amt of tissue irradiation to a minimum and substantially
improves image great and reduces pt dose

bremsstralung x-rays - ANS-happens while incident electrons skip near the positively charged
nucleus which ends up in the incident electron braking or slowing down, every deflection causes
a photon of radiation
makes up most of the primary beam

cathode - ANS-a negatively charged electrode that is the supply of electrons in an electrical
device

ceiling guide machine - ANS-maximum common, has 2 sets of rails that allow for lateral and
longitudinal motion, lock and raise and lower to reap the ideal distances

valuable ray - ANS-A line within the middle of the X-ray beam and perpendicular to the lengthy
axis of the X-ray tube

chemical fog - ANS-Type of fog that outcomes while the film processing chemical are too hot or
too strong.

Collimator definition - ANS-A container-like tool connected underneath the tube housing that
permits the constrained operator to vary the dimensions of the radiation discipline (a variable
aperature)

compensating filter - ANS-used for shaping the xray intensity over the beam location so
radiation that reaches th IR is more uniform and produces more unifom optical density

compton impact - ANS-An attenuation (absorption) manner for x- and gamma radiation in which
a photon interacts with an orbital electron or an atom to shape a displaced electron and a
scattered photon (x-ray) of reduced strength.
Reasons x-rays to be scattered in all directions

Infos sur le Document

Publié le
16 juillet 2026
Nombre de pages
13
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses
9,74 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Vendu
0
Abonnés
0
Éléments
317
Dernière vente
-




Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions