Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Document preview thumbnail
Aperçu 2 sur 5 pages
Examen

CT REGISTRY 2026 QUESTIONS AND ANSWERS SURE A.pdf

Document preview thumbnail
Aperçu 2 sur 5 pages

CT REGISTRY 2026 QUESTIONS AND ANSWERS SURE A.pdf

Aperçu du contenu

CT REGISTRY 2026 QUESTIONS AND ANSWERS SURE A+
✔✔phantom roi measures -987 it most likely represents what? - ✔✔air

✔✔Which of the following will serve to decrease the noise of a CT image - ✔✔decrease
matrix size

✔✔beam hardening - ✔✔The phenomenon whereby low-energy photons are absorbed
as the x-ray beam passes through an object, resulting in an increase in the average
photon energy of the beam. or
Beam hardening occurs as the x-ray beam traverses the patient. The x-ray beam used
in CT is composed of x-ray photons with numerous different energies. The
heterogeneous beam undergoes an increase in average photon energy as it passes
through the patient and the lower-energy photons are absorbed

✔✔ Circle of Willis (cerebral arterial circle) - ✔✔♣ R/L posterior cerebral arteries
♣ R/L posterior communicating arteries
♣ R/L internal carotid arteries
♣ R/L anterior cerebral arteries
♣ Anterior communicating artery

✔✔Circle of Willis (cerebral arterial circle) - ✔✔label diagram

✔✔Wrist - ✔✔know wrist bones/Never Lower Tilly's Pants Grandma Might come home

✔✔Brain Anatomy - ✔✔Brain Lobes
-Frontal
-Parietal
-Temporal
-Occipital
-Cerebellum
Brain stem

✔✔Brain Anatomy - ✔✔hindbrain, midbrain, fore brain

✔✔Brain Anatomy - ✔✔functions of each

✔✔CT IAC - ✔✔Refers to ears-internal auditory canal

✔✔PHOTON MEASUREMENT - ✔✔IT MUST ENTER DETECTOR CHAMBER, BE
ABDORBED BY DETECTOR MATERIAL, AND BE CONVERTED TO A MEASURABLE
EVENT

✔✔Name system that converts projection into proper digital form for array processor -
✔✔analog to digital convertor

, ✔✔PACS - ✔✔long term data storage, digital distribution of images, image display for
radiologists

✔✔CT system components - ✔✔Console, Host computer, Scan controller, DAC, High
voltage generator, Gantry control, Gantry, Amplifier, S&H, ADC, Array processor,
Storage device

✔✔CT Systems - ✔✔Systems are perfectly designed to get the results they get

✔✔A CT system manufacturer has a scanner in which the focal spot of the x-ray beam
can move to two, slightly separated, distinct locations. What benefit does the dual focal
spot provide compared to an identical scanner possessing a single focal spot?
1. the number of projections is doubled
2. the number of rays in a single projection is doubled
3. the patient dose is halved
a. 1 only
b. 2 only
c. 3 only
d. 1, 2 & 3 - ✔✔

✔✔CT Systems - ✔✔All FALSE: Have no moving parts, cannot generate straight
coronal and sagittal image, limited to non-oblique transverse scanning

✔✔CT uses xrays why? - ✔✔they penetrate the body according to specific attenuation
characteristics of each tissue

✔✔Operators console - ✔✔is the key point of interaction between the technologist and
the imaging system

✔✔THE OPERATORS CONSOLE MAY INCLUDE - ✔✔1. MOITOR
2. KEYBOARD
3, GRAPHIC INPUT DEVICE

D. ALL THREE ARE USED TO PROVIDE THE TECH THE GREATEST FLEXIBILITY
IN SYSTEM OPEARION AS WELL AS EASE OF USE

✔✔CT Commands from tech - ✔✔received mostly by operators console

✔✔X-rays are produced when - ✔✔fast moving electrons collide with any kind of matter
because the electron loses kinetic energy which is converted into the emission of an x-
ray photon.

✔✔THE MA DETERMINES THE - ✔✔A. QUANTIFY OF XRAY PHOTONS

Infos sur le Document

Publié le
12 juin 2026
Nombre de pages
5
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses
16,87 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
EXAMCAFE
3,4
(19)
Vendu
154
Abonnés
7
Éléments
26055
Dernière vente
1 semaine de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions