This document covers Quiz 4 for ESA II, focusing on key energy and sustainability analysis concepts such as energy systems, environmental impacts, renewable energy, resource management, and sustainability frameworks. It includes structured quiz-style questions and revision content designed to support effective learning and exam preparation. The material is intended to help students reinforce understanding of core ESA II topics and prepare efficiently for quizzes and assessments.

Aperçu du contenu

ESA II – Quiz 4 – Energy and Sustainability Analysis – practice material


Reclaimed Water - correct answer ✔✔all of these, must be used to recharge the aquifer, may be
used for irrigation, may be releases into surface bodies



which water distribution method is good for buildings that are small enough to be served by the
pressure available in water mains - correct answer ✔✔municipal pressure up-feed



when is comes to on-site sewage treatment, what are septic tank drainfields (or leachfields) -
correct answer ✔✔perforated in trenches of gravel for waste water infiltration



all of the following are required components of a typical building sewage system except -
correct answer ✔✔sewage pump



the natural or man-made sinkholes used in the Yucatan peninsula to access ground water are
called - correct answer ✔✔cenotes



The IPC Terms for the fixture required in all buildings for use by custodial staff for a variety of
cleaning purposes is called a - correct answer ✔✔service sink



for tall buildings all of the following are advantages of up-feed pumping in comparison to down-
feed distribution except - correct answer ✔✔elimination of periodic cleaning of the tank



all of the following are guidelines for good building sewrage/waste water systems except -
correct answer ✔✔dont use more than one vertical stack or use one vertical stack for each
fixture.



what is the primary disadvantage of internal roof drains for flat roofs - correct answer ✔✔the
drainpipes come down inside the building

, which type of water closet allows a choice of less water for liquid waste and more water for
solid waste - correct answer ✔✔dual flush



what percentage of the worlds population is projected to live under water stress in the year
2025 - correct answer ✔✔66%



lightly used waste water (from lavatories and showers for example) is called - correct answer
✔✔grey water



which of the four minimum required fixtures does not usually require a trap - correct answer
✔✔water closet



the fixture required by the IPC for water consumption is called a - correct answer ✔✔drinking
fountain



which part of a buildings water and waste system has the greatest impact on interior space -
correct answer ✔✔sewerage



parking lots can be made more low-impact-development friendly by all of the following
strategies Except - correct answer ✔✔multiple connections to municipal storm sewer system



all of the following are key goals of low impact development except - correct answer
✔✔building reuse of retained water



proper design of a building wastewater system is required by code - correct answer ✔✔yes



what is the biggest impact of human development on the natural hydrologic cycle - correct
answer ✔✔higher volume of runoff (five times natural rate)

Infos sur le Document

Publié le
16 avril 2026
Nombre de pages
6
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses
12,23 €

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
BravelRadon
3,5
(165)
Vendu
965
Abonnés
541
Éléments
53923
Dernière vente
1 jours de cela




Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions