Home Inspector Florida Test Practice Questions with correct answers
Air-admittance valves are __________ to vent fixtures installed at island structures in kitchens. CORRECT ANSWER Permitted The door between an attached garage and a dwelling unit should be of solid wood not less than ________ inches thick. CORRECT ANSWER 1 3/8 If particleboard panels used as wall sheathing are applied in a horizontal pattern across the wall, the end joints should be offset so that four panel corners ________. CORRECT ANSWER do not meet The size of a P-trap drainpipe should be at least _______ inches. CORRECT ANSWER 1.5 Notches in solid lumber joists, rafters and beams should not be longer than ____________ the depth of the member. CORRECT ANSWER 1/3 A minimum service of _____ amps is required for a single residential dwelling unit. CORRECT ANSWER 100 If the service or feeder rating in amps is 200, then the aluminum AWG size should be _______. CORRECT ANSWER 4/0 T/F: In homes located in areas having a history of ice forming along the eaves, an ice barrier consisting of at least three layers of underlayment cemented together is required. CORRECT ANSWER True There should be at least ____-inch gypsum board applied on the garage side to separate the garage from the residence and its attic space. CORRECT ANSWER 1/2