An aquastat stops and starts a burner by sensing the ___ temperature. - ANSWERSBOILER WATER The number of blowdowns required for a boiler can be determined by ___. - ANSWERStesting the boiler water Oxygen in a boiler causes ___. - ANSWERSPITTING Impurities on the water surface in a steam and water drum are best removed by ___ blowdown. - ANSWERSSURFACE A modulating pressure control on a steam boiler is used to control the ___. - ANSWERShigh and low fire ranges A(n) ___ is a boiler water treatment accessory that heats feedwater to the temperature of saturated steam within the pressure vessel. - ANSWERSdeaerator When a boiler reaches a pressure above the safety valve setting, the operator must first ___. - ANSWERSsecure the boiler The first thing a boiler operator should do when taking over a shift is check the ___ for each boiler that is operating. - ANSWERSwater level in the gauge glass A boiler generating 20,000 lb/hr of steam must be supplied with at least ___ of feedwater. - ANSWERS20,000 lb/hr When starting a boiler and bringing it on-line in battery with another boiler, the main steam stop valve should be opened ___ than the header pressure. - ANSWERSslowly when the boiler pressure is slightly less As a precaution when giving a boiler a bottom blowdown, boiler operators should ___. - ANSWERSalways check the boiler water level On a boiler under steam pressure, if the top gauge glass fitting from the water column is blocked, then the water level in the gauge glass will ___ if the water level in the boiler remains constant. - ANSWERSINCREASE When a boiler is being cleaned, repaired, or inspected, the main steam stop valve must be ___. - ANSWERStightly closed, locked, and tagged out

Montrer plus Lire moins
Établissement
Boilers License Practice
Cours
Boilers License Practice








Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Boilers License Practice
Cours
Boilers License Practice

Infos sur le Document

Publié le
13 janvier 2026
Nombre de pages
4
Écrit en
2025/2026
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

Boilers License Practice Test #1
Questions with Correct Answers
An aquastat stops and starts a burner by sensing the ___ temperature. -
ANSWERSBOILER WATER

The number of blowdowns required for a boiler can be determined by ___. -
ANSWERStesting the boiler water

Oxygen in a boiler causes ___. - ANSWERSPITTING

Impurities on the water surface in a steam and water drum are best removed by ___
blowdown. - ANSWERSSURFACE

A modulating pressure control on a steam boiler is used to control the ___. -
ANSWERShigh and low fire ranges

A(n) ___ is a boiler water treatment accessory that heats feedwater to the temperature
of saturated steam within the pressure vessel. - ANSWERSdeaerator

When a boiler reaches a pressure above the safety valve setting, the operator must first
___. - ANSWERSsecure the boiler

The first thing a boiler operator should do when taking over a shift is check the ___ for
each boiler that is operating. - ANSWERSwater level in the gauge glass

A boiler generating 20,000 lb/hr of steam must be supplied with at least ___ of
feedwater. - ANSWERS20,000 lb/hr

When starting a boiler and bringing it on-line in battery with another boiler, the main
steam stop valve should be opened ___ than the header pressure. - ANSWERSslowly
when the boiler pressure is slightly less

As a precaution when giving a boiler a bottom blowdown, boiler operators should ___. -
ANSWERSalways check the boiler water level

On a boiler under steam pressure, if the top gauge glass fitting from the water column is
blocked, then the water level in the gauge glass will ___ if the water level in the boiler
remains constant. - ANSWERSINCREASE

When a boiler is being cleaned, repaired, or inspected, the main steam stop valve must
be ___. - ANSWERStightly closed, locked, and tagged out
€11,05
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Bestgrades2 West Virginia University
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
23
Membre depuis
1 année
Nombre de followers
0
Documents
4142
Dernière vente
3 mois de cela

4,0

3 revues

5
1
4
1
3
1
2
0
1
0

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions